JHS JHSB
Insulated
Stranded
Overhead, Heating, Underground, Submersiable Pump
Copper
Rubber
Rubber
Round or Flat
Flame Retardant
ISO9001, CE, CCC, RoHS, VDE
Qif
Black, Red
1&2
Not Be Lower Than-10c
Not Be Lower Than-10c
Support
Flexible Copper
QIF
Plastic Film, Wooden Reel, Wooden Drum
10mm2-185mm2
China
8544609
Product Description
Application
For continuous use in deep well to supply power to submersible pumps down to depths of 500 mtrs. Double sheathed round pump cables are better suited for heavy duty application like sewage, slurry and dewatering pumps. These conditions requires the sheathing to be able to with stand abrasion, prevent ingress of water along the interstices of the cable and be resistant to acidic fluids and chemicals.
Characteristics
Rated Voltage: 300/500V,450/750V,600/1000V
Test Voltage: 1.5KV,2.5KV,3.5KV
Type: Flat /Round
Conductor Working temperature: 85°C
Insulated: EPR/PVC/Rubber.
Ambient temperature: Fixed:-40°C to 90°C; Mobile:-25°C to 90°C
Flame retardant: VDE 0482-332-1-2/IEC 60332-1






We provide free sample and will courier to you by DHL, FEDEX, UPS, TNT, etc. swiftly according to your requirements.
For continuous use in deep well to supply power to submersible pumps down to depths of 500 mtrs. Double sheathed round pump cables are better suited for heavy duty application like sewage, slurry and dewatering pumps. These conditions requires the sheathing to be able to with stand abrasion, prevent ingress of water along the interstices of the cable and be resistant to acidic fluids and chemicals.
Characteristics
Rated Voltage: 300/500V,450/750V,600/1000V
Test Voltage: 1.5KV,2.5KV,3.5KV
Type: Flat /Round
Conductor Working temperature: 85°C
Insulated: EPR/PVC/Rubber.
Ambient temperature: Fixed:-40°C to 90°C; Mobile:-25°C to 90°C
Flame retardant: VDE 0482-332-1-2/IEC 60332-1


3CORE ROUND SUBMERSIBLE PUMPS CABLES | |||||||
CONDUCTOR | RUBBER INSULATION | TOTAL THICKNESS OF DOUBLE RUBBER SHEATH | Conductor Resistance at 20°C (max) ohms/km | CURRENT Rating at 40°C Amps. | |||
Nominal Area in | Nos. & Dia.of wire | Nominal Thickness | Nominal Core Dia. | Nominal Thickness | Approx. Overall Dimensions | ||
Sq. mm. | Nos. / mm | mm | mm | mm | mm | ||
1.5 | 22/0.30 | 0.8 | 3.25 | 1.5 | 10 | 12.1 | 14 |
2.5 | 36/0.30 | 0.9 | 3.84 | 1.5 | 11 | 7.41 | 18 |
4 | 56/0.30 | 1 | 4.5 | 1.6 | 13 | 4.95 | 26 |
6 | 85/0.30 | 1 | 5.3 | 1.6 | 14.6 | 3.3 | 31 |
10 | 140/0.30 | 1 | 6.5 | 2 | 18 | 1.91 | 42 |
16 | 226/0.30 | 1 | 8 | 2 | 21.2 | 1.21 | 57 |
25 | 354/0.30 | 1.2 | 10.1 | 2.15 | 26 | 0.78 | 72 |
35 | 495/0.30 | 1.2 | 11.3 | 2.15 | 28.3 | 0.554 | 90 |
50 | 703/0.30 | 1.4 | 13.6 | 2.25 | 33.5 | 0.386 | 115 |
70 | 440/0.45 | 1.4 | 15.3 | 2.45 | 37.8 | 0.272 | 143 |
95 | 475/0.50 | 1.6 | 18 | 2.4 | 43.5 | 0.206 | 165 |
4CORE ROUND SUBMERSIBLE PUMPS CABLES | |||||||
CONDUCTOR | PVC INSULATION | TOTAL THICKNESS OF DOUBLE PVC SHEATH | Conductor Resistance at 20°C (max) ohms/km | CURRENT Rating at 40°C Amps. | |||
Nominal Area in | Nos. Dia.of wire | Nominal Thickness | Nominal Core Dia. | Nominal Thickness | Approx. Overall Dimensions | ||
Sq. mm | Nos. / mm | mm | mm | mm | mm | ||
1.5 | 22/0.30 | 0.8 | 3.25 | 1.5 | 10.8 | 12.1 | 14 |
2.5 | 36/0.30 | 0.9 | 3.84 | 1.65 | 12.5 | 7.41 | 18 |
4 | 56/0.30 | 1 | 4.5 | 1.65 | 14.1 | 4.95 | 26 |
6 | 85/0.30 | 1 | 5.3 | 1.65 | 16 | 3.3 | 31 |
10 | 140/0.30 | 1 | 6.5 | 2 | 20.35 | 1.91 | 42 |
16 | 226/0.30 | 1 | 8 | 2 | 23.4 | 1.21 | 57 |
25 | 354/0.30 | 1.2 | >10.10 | 2.2 | 28.8 | 0.78 | 72 |
35 | 495/0.30 | 1.2 | 11.5 | 2.2 | 31.5 | 0.554 | 90 |
50 | 703/0.30 | 1.4 | 13.6 | 2.3 | 37.3 | 0.386 | 115 |
70 | 440/0.30 | 1.4 | 15.3 | 2.6 | 42.2 | 0.272 | 143 |
95 | 475/0.50 | 1.6 | 18 | 2.65 | 48.8 | 0.206 | 165 |