Product Description
I. System purpose :
Accurately and quickly detect the main insulation failure of power cables with voltage
levels of 35KV and below; calibrate the cable length; accurately detect the direction
and depth of the cable buried.
II. System Configuration
Product name | Model No. | Qty.(unit) |
cable fault pre locator | XHGG502 | 1 |
cable pipeline locator | XHGX504 | 1 |
high voltage pulse generator | XHHV535-4TS | 1 |
III. Main technical parameters of the system: :
★Cable fault pre-location: with the reflectometer XHGG502 based on the low-voltage impulse reflection method(TDR), and high-voltage decay(flashover) method (DECAY), multiple impulse(ARC)arc reflection method.
★cable route tracer: XHLJ504 Using the principle of electromagnetic induction, now electronic technology, high power and small size, for finding the path and radiation depth of out-of-service and faulty cables.
★XHHV535-4TS High voltage 2048 J surge generator is accompanied by a surge levels switch which allows to achieve the maximum surge impulse energy at 8, 16 and 32 kV. It has features operator safety assurance systems and provides a reliable and comprehensive technical solution for low- and medium-voltage cables faults.



XHGG502


high voltage surge generator XHHV535-4TS | Surge voltage levels and adjustment ranges | Level 1 : 0-8KV Level 2: 0-16KV Level 3: 0-32KV |
High voltage divider: | Voltage Accuracy 1.5 grade | |
Inside capacitor: | 4μF/32kV,16μF/16kV, 64μF/8kV | |
Surge energy: | 2048J | |
Surge power: | 2KVA | |
Operating mode | Single trigger/cycle/DC | |
Impact time | about 5 seconds for automatic impact, arbitrary control time for manual impact | |
Safe protection | With zero start protection function, safe and reliable | |
Discharge | Unique high-voltage measurement design, in the stop state, it will automatically discharge the internal capacitance of the device | |
DC withstand voltage testing | Output voltage adjustment and indication range 0-32KV, Output current indication range 0-20A | |
Burn current | Up to 160mA | |
Connecting cable | High voltage output cable: 5m, Power supply cable: 1.8m, Protective earthing cable: 3m | |
Safety | Overvoltage, Over-current, Overheating protection. Automatic discharge after operation. | |
Protection rating | Not lower than IP54 | |
GW | 120kg |