MQ31
Within 1 Year. Any Problem, We Will Send New Devic
1 Year
Digital
Direct Connected
Multi-Functional Energy Meter, Meter for Industry and Home Use, Standard Electric Energy Meter, Reactive Energy Meter, Energy Power Consumption Analysis
Three-phase Four-wire
Electronic Meter
3.5mm Headphone Jack
Current and Voltage
Power Meter
ISO, CE
Non-Customized
Rogowski Power Data Logger, Energy Meter
Portable Power Quality Analyzer
Power Analysis, Electric Energy Measurement
Three Phase
16GB Micro SD Card, USB Disk Download
8-Inch Capacitive Screen
Rogowski Coil, Voltage-Output Current Clamp
600A, 3000A, 6000A
5-528V AC
45-65Hz
IEC62053-22 Class 0.5s
Trend Chart, Event Data, Real Time Waveform
Active Power, Reactive Power, Apparent Power
Temperature and Humidity
51 Time
MEATROL
Standard Export Carton
415x319x168MM
Shanghai, China
9030331000
Product Description

World-famous manufacturer
Three major production bases in Shanghai, Chongqing, and Zhejiang
Looking forward to in-depth communications, project cooperation, and exclusive agency
Three major production bases in Shanghai, Chongqing, and Zhejiang
Looking forward to in-depth communications, project cooperation, and exclusive agency





MQ31 Portable Power quality analyzer:
Advantage:
* Event data record
* Record Voltage Swell, Voltage Dip, Three-Phase Unbalance
* Support Rogowski coil and CT
* 32GB Micro SD card, USB data export
* High speed Ethernet transmission
* Support 4G Gateway transmitting data to Cloud
* Electricity from major loop, no need extra affiliated power supply
Advantage:
* Event data record
* Record Voltage Swell, Voltage Dip, Three-Phase Unbalance
* Support Rogowski coil and CT
* 32GB Micro SD card, USB data export
* High speed Ethernet transmission
* Support 4G Gateway transmitting data to Cloud
* Electricity from major loop, no need extra affiliated power supply
Test function
★ Real time waveform of voltage and current
★ Pharos diagram and trend chart display
★ Harmonic up to 50 times
★ Active, reactive, apparent power of each phase and total
★ Current K-factor and crest factor
★ Three phase unbalance (current and voltage).
Optional Rogowski coil sensor:
600A(6A~720A): TRC-36
3000A(10A~3600A): NRC-150
6000A((20A~10000A): NRC-200
10A(100mA~10A): Current clamp ST08
Event data record:
Even type
Start time
Duration
Amplitude value
Voltage RMS1/2 value of each phase
Voltage waveform of each phase
★ Real time waveform of voltage and current
★ Pharos diagram and trend chart display
★ Harmonic up to 50 times
★ Active, reactive, apparent power of each phase and total
★ Current K-factor and crest factor
★ Three phase unbalance (current and voltage).
Optional Rogowski coil sensor:
600A(6A~720A): TRC-36
3000A(10A~3600A): NRC-150
6000A((20A~10000A): NRC-200
10A(100mA~10A): Current clamp ST08
Event data record:
Even type
Start time
Duration
Amplitude value
Voltage RMS1/2 value of each phase
Voltage waveform of each phase

MQ31
Power quality analyzer
1 Product description
MQ31 three-phase power quality analyzer, externally connected with open type Rogowski coil or voltage type CT, it can realize no dismantling wire test, simplify test steps, save construction cost, and is more convenient for engineering test as well as the inspection and maintenance of distribution system. MQ31 supports systems of single-phase and three-phase, it can measure multiple electrical parameters such as current, voltage, power factor, harmonic, active power, electric energy on the power grid of phase A, B, C and Neutral phase. With standard configuration of RJ45 and RS485 communication interfaces, through standard Modbus TCP and Modbus RTU protocols, it can be compatible with various configuration systems and transmit the electrical parameters collected by the front end to the system data center in real time.Description | |
Model No. | MQ31 |
Type | Three-phase power quality analyzer |
Supported types of current sensor | Rogowski coil, Voltage-output current clamp |
Wiring mode | 3P4W(4CT), 3P4W(3CT), 3P3W(3CT), 3P3W(2CT), Single phase |
Storage | 16GB Micro SD card, USB DISK Download (Default storage interval: 1 minute) |
Harmonic | Simultaneous 51 times |
Application field | Power analysis, Electric energy measurement |
Display screen | 8-inch capacitive screen |
Weight | Approx 5kg |
Dimension | L*W*D:415x319x168MM |
Color | Black |
Input current | |
Primary side current range | 600A 0.5A ~ 720A 3kA 0.5A ~ 3600A 6kA 0.5A ~ 7200A |
Secondary side current range(ST08 current clamp or the same type) | 1mA~10A |
Input voltage value | 1/225mV~707mV |
Overload capacity | 2V,10s/hours |
Power supply | |
Power supply | Electricity from major loop, 90~528VAC |
Power consumption | |
Max power consumption | 15W |
Connecting terminal type | |
ABC phase current input | 3.5mm Headphone jack |
Voltage input | 4mm Banana plug |
2 Function
Measurement | |
Voltage | UA, UB, UC, and average value |
Current | IA, IB, IC, IN, and average value |
Power | Active power, Reactive power, Apparent power (each phase, sum value of three phase) |
Energy | Active energy, Reactive energy, Apparent energy (each phase, sum value of three phase) Exceeds 999.9GWh, energy value automatically cleared to "0" |
Line voltage | Between phases |
Angle between line voltage | Between phases |
Angle between currents | Between phases |
Power factor | Including harmonic power factor PF and fundamental power factor DPF (each phase, average value of three phases) |
Max/Min. | |
Voltage | Each phase, average value of three phases |
Current | Each phase, average value of three phases |
Power | Active power, Reactive power, Apparent power (each phase, sum value of three phases) |
Unbalance degree | |
Voltage | Each phase, the max unbalance degree of three phases |
Current | Each phase, the max unbalance degree of three phases |
Demand/Max Demand | |
Current | Each phase, average value of three phases |
Power | Active power, Reactive power, Apparent power (each phase, sum value of three phases) |
Temperature and humidity ( Optional) | |
Temperature | 3 channels |
Humidity | 1 channel |
Power quality | |
Voltage swell | Start time, end time, amplitude value |
Voltage dip | Start time, end time, amplitude value |
Voltage harmonic value and percentage | Total harmonic, 1, 2, 3, 4...51 (51st) harmonics |
Current harmonic value and percentage | Total harmonic, 1, 2, 3, 4...51 (51st) harmonics |
General data record | |
Time interval record setting | 5~9999s (default 60s) |
Data format | .CSV |
Storage capacity | Micro SD card: 16GB |
Storage duration 3 years ( using 16GB SD card, 1 time/60s) | |
Recorded data | Basic data Voltage harmonic Current harmonic |
Event data record | |
Data fromat | .CSV |
Recorded data | Even type Start time Duration Amplitude value Voltage RMS1/2 value of each phase Voltage waveform of each phase |
3 Accuracy and certification
Measurement accuracy | ||
Rogowski coil | Current measurement accuracy | 0.5%(1%~120% rated current), (<10A no guaranteed accuracy) |
Current gear | 600A(6A~720A): Rogowski coil TRC-36, 50mV/kA | |
3000A(10A~3600A): Rogowski coil NRC-150, 85mV/kA | ||
6000A(20A~7200A): Rogowski coil NRC-200, 50mV/kA | ||
ST08 current clamp | Current measurement accuracy | 0.5%(100mA~10A) |
1%(10mA~100mA,(<10mA no guaranteed accuracy) | ||
ABC Voltage measurement accuracy | 0.2%(5~528V AC) | |
Power factor | ±0.005 | |
Active and apparent power | IEC62053-22 Class 0.5S | |
Reactive power | IEC62053-21 Class 2S | |
Frequency | 0.01%(45~65Hz) | |
Active energy | IEC62053-22 Class 0.5S | |
Reactive energy | IEC62053-21 Class 2S | |
Environment condition | ||
Operating temperature | -25ºC~+55ºC | |
Storage temperature | -40ºC~+85ºC | |
Humidity range | 5~95% RH,50ºC(non-condensing) | |
Pollution level | 2 | |
Overvoltage capacity | III,applicable to the distribution system below 277/480VAC | |
Insulation strength | IEC61010-1 | |
Altitude | 3000m Max | |
Anti-pollution level | IP20(conforming to IEC 60629) | |
Product warranty | 24 months | |
EMC(Electromagnetic compatibility) | ||
Electrostatic discharge | Level IV(IEC61000-4-2) | |
Radiation Immunity | Level III (IEC61000-4-3) | |
EFT Electrical Fast Burst Immunity | Level IV (IEC61000-4-4) | |
Surge immunity | Level IV (IEC61000-4-5) | |
Immunity to Conducted Disturbance | Level III (IEC61000-4-6) | |
Power frequency magnetic field immunity | 0.5mT (IEC61000-4-8) | |
Conduction and Radiation | Class B (EN55022) | |
Standard compliance | ||
EN62052-11, EN61557-12, EN62053-21, EN62053-22, EN62053-23, EN50470-1, EN50470-3, EN61010-1, EN61010-2, EN61010-031 |