220V 120A Multi-Positions Single Phase Kwh Meter Test Bench

Price $80000.00 Compare
Min Order 1 Set
Shipping From Beijing, China
Popularity 369 people viewed
Quantity
+-
 

Beijing GFUVE Electronics Co., Ltd.

VIP   Audited Supplier 12 years
Profile Certified by SGS/BV
GF1000
24 Hour Service
3 Years
Energy Meter Test Bench
0.05, 0.1
Digital
Computer Control
500-1000Kg
AC220V
Multi-Positions Single Phase Kwh Meter Test Bench
0.02%, 0.05%, 0.1%
12, 24, 48
0.05%
0-120A, 0-380V
48PCS
Yes
Yes
Yes
Energy Meter Accuracy Test and Manufacturer
GFUVE
Standard Carton Box
GF1000 120A/220V 0.05%
Beijing China
90308490
Product Description

GF1000MULTI-POSITIONS SINGLE PHASE KWH METER TEST BENCH

The GF1000 series multi-positions single phase kWh meter test bench can measure mechanical meters, electronic mechanical meters and electricity meter error by the way of automatic, semi-automatic or manual operation. It composes of single phase programmable power source, high precision single phase reference energy meter, meter suspension test rack, Multi-channel server and precision clock source etc. GF1000 meter test bench is applied in the measurement centre of grid company energy measurement department of power supply company and energy management utility, industrial enterprise and meter manufacturers.

FUNCTIONS

Testing single-phase meters under tampered conditions;

Calibration of lower accuracy reference standard meter;

Able to print out all kinds of test reports with the standard forms;

Calibrate all kinds of electronic and inductive single phase kWh meter;

Influence quantity test (voltage, frequency, harmonic distortion, etc.);

Pre-warming;

Meter constant test;

Starting current test;

Creep test (No-load test);

Dips and Interruptions;

Dial test (Register test);

Equipped with RS232 communication port;

Automatic measurement like shunting, basic errors, standard deviation etc;

Accuracy test in all four quadrants (active, reactive and apparent energy);

Test voltage, current, active/reactive/apparent power, phase, power factor, frequency, and etc;

Able to display waveform of voltage and current able to set 2nd-51st harmonic of voltage and current, measure the waveform distortion and harmonic content, and display harmonic chart;

FEATURES

High resolution of voltage, current and power;

Large LCD display and simple interface for operation;

Full automatic, semi automatic and manual operation available;

Aluminum alloy material,light and strong and corrosion resistant;

Wide current measuring range which can be automatically switched;

With auto PC control software;

With barcode scanning function optional;

Meter positions can be chosen from 3 - 48;

Self-check and perfect protection function;

High stability of power source which is up to 0.01%/100s and low distortion which is no more than 0.3%;

High accuracy, 6-digit display the energy relative errors are no more than 0.05%(0. 1%)within the measuring range;

Equipped with sing phase mulfunction reference meter and progam-conrolled single phase power source which can be separately used and are convenient for testing;

PARAMETERS

Electrical parameters
Accuracy0.02%, 0.05%, 0.1%
Power SupplyAC 180-265V, or 3×220/380V±15%, frequency 50/60Hz.
AC Voltage Output
Range57.7V, 100V, 220V, 380V (max 480V)
Adjustment range(0-120)%RG(1)
Adjustment fineness0.01%RG, 0.1%RG, 1%RG, 10%RG as optional.
Stability0.01%/120s
Distortion0.3% (Non-capacitive load)
Output load1500VA
Measuring accuracy0.02%RG or 0.05% RG
AC Current Output
Range(I1,I2,I3)0.1A, 0.25A, 0.5A, 1A, 2.5A, 5A, 10A, 25A, 50A, 100A, 120A
Adjustment range(0-120)%RG
Adjustment fineness0.01%RG, 0.1%RG, 1%RG, 10%RG as optional.
Stability<0.01%/120s
Distortion≤0.3% (Non-capacitive load)
Output load1500VA
Accuracy0.02%RG or 0.05% RG
Power Output
Active power output stability<0.01%RG/120s
Reactive power output stability<0.02%RG/120s
Active power measuring accuracy0.02%RG or 0.05% RG
Reactive power measuring accuracy0.1%RG
Phase Output
Output adjustment range0°-359.999°
Output adjustment fineness10, 1, 0.1, 0.01 as optional.
Resolution0.01°
Accuracy0.02° or 0.05°
Power Factor
Adjustment range-1 ~ 0 ~ 1
Resolution0.0001
Measurement accuracy0.0005
Frequency Output
Adjustment range40Hz-70Hz
Output adjustment fineness5Hz, 1Hz, 0.1Hz, 0.01Hz as optional.
Resolution0.001Hz
Accuracy0.002Hz
Voltage /Current/Harmonic Setting
Harmonic number2-51times
Harmonic content0-40%
Harmonic phase0-359.99
Harmonic setting accuracy(10%±0.1%)RD(2)
Power Energy Measurement Error
Active power energy0.05%RG or 0.02% RG
Reactive power energy0.1%RG
Power Pulse Output
Power pulse typeactive pulse, reactive pulse
Active power pulse output5V, 10mA
Pulse output frequencyMax 50kHz
Power Pulse Input
Pulse constant set range(1--599999999)/kwh
Energy pulse typesupport active and reactive pulse, the highest frequency power pulse input is 200KHz.
Meter Position
Position3, 6, 12, 20, 24, 40, 48pcs meter
Standard
StandardIEC 62053-21,22, 23; IEC 60736; ANSI C12.20-2002;
JJG 597-2005; JJG596-2012; JJG 1085-2013; JJF 68-2019;
DL/T 826-2002; DL/T 1478-2015; DL/T 448-2016;
EN 50470-1, EN 50470-2, EN-50470-3; IEC 61010;
Safety
Isolation protectionIEC 61010-1:2001
Measurement Category300 V CAT III, 600 V CAT II
Degree of protectionIP20
Declaration of conformityCE & CNAS certified
Mechanical parameters
Dimensions (W×D×H) (mm)Cabinet size: 800 * 600 * 1850mm (L * W * H).
Bench size: 2*2400 * 760 * 1846mm (L * W * H).
Weight (kg)About 200
Environmental conditions
Ambient temperature0°C to +40°C
Relative humidity35%-85%
(1) RG means range, the same as below;
(2) RD means the setted harmonic content, harmonic can be a single output, also multiple output.

RELATED PRODUCTS

 