LZCK-55
Electronic, Instrument
Current Transformer
Single
Outdoor
Protection, Measurement
Single Layer & Tightly Wound Type
Common Insulating Materials
Active Type
Single Stage Type
Electromagnetic Type
Waterproof Outdoor Split Core Current Transformer
Outdoor Split Core Current Transformer
0.5s, 0.5%, 1%, 3%
100-1500A
5A or 1A
50/60Hz
55
IP67
Power Monitoring
2kg
GFUVE
Standard Export Wooden Box
180mm*138mm*52mm
Beijing, China
Product Description
LZCK-55 200a clamp ct/ IP67 Clamp on current transformer/ Waterproof Outdoor Split Core Current Transformer
LZCK series outdoor waterproof current transformers are applicable for AC power system 35kV and measurement of current of power supply equipment below 10KV also can be used for microcomputer protection. This type of current transformer employs imported silicon steel which with high permeability as magnetic material, has the characteristics of Small magnetic circuit loss and can be split, its semicircular core and secondary windings employ high quality epoxy resin vacuum, casting in plastic-case(ABS or PC) which is flame retardance anti-moisture, stable performance, no maintenance.
Parameters
Selection guide





LZCK series outdoor waterproof current transformers are applicable for AC power system 35kV and measurement of current of power supply equipment below 10KV also can be used for microcomputer protection. This type of current transformer employs imported silicon steel which with high permeability as magnetic material, has the characteristics of Small magnetic circuit loss and can be split, its semicircular core and secondary windings employ high quality epoxy resin vacuum, casting in plastic-case(ABS or PC) which is flame retardance anti-moisture, stable performance, no maintenance.
Parameters
Technical parameters | |
Standards | IEC60044-1; IEC 61869-2; NTC 2205; GB1208-2006; ANSI C57.13 |
Accuracy Class | 0.5S, 0.5%, 1%, 3% |
Range of primary rated current | 100-1500A |
Technical parameters - continued | |
Range of Rated load | ≤10VA |
Rated frequency | 50/60Hz |
Rated secondary current | 5A or 1A |
Rated short-me thermal current | 40kA, 1S |
Rated connuous thermal current | 150%I1n |
Secondary winding power frequency withstand voltage | 3kV, 1min |
Safety Factor Rang | (FS) <10 |
Output signal | 1A, 5A, 333mV, 1V or 5V(customized) |
Mechanical parameters | |
Aperture (mm) | Φ55 |
Dimensions (W×D×H) (mm) | 180×138×52 |
Weight (kg) | 2 |
Working condions | |
Operang temperature | -35°C to +65°C, average not exceeding +40°C |
Storage temperature | -40°C to +70°C |
Ingress Protecon | IP65 |
Environment | outdoors or indoors |
The Height of above sea level | 0- 3000m |
Condions | No existence of severely begrimed, erosive and radioacve gas in the air. Connuous working under the rated current is allowed. |
Model | Primary rated current | Rated load | Aperture (mm) | Descripon (mm) | Weight (kg) | Materia l | Water-proof |
LZCK-55 | 100-1500A | ≤10VA | φ55 | 180×138×52 | 2 | PC | IP65 |
LMCK185-10 | 300-3000A | ≤25VA | φ185 | 350×283×55 | 4.5 | PC | IP65 |
LZCK310-10 | 300-600A | ≤10VA | φ50 | φ50 x φ110 x 32 | 1 | Resin | silicon case (option) |
LZCK322-10 | 30-600A | ≤10VA | φ50 | φ50 x φ110 x 52 | 1.6 | Resin | silicon case (option) |
LZCK350-10 | 20-600A | ≤25VA | φ50 | φ50 x φ110 x 105 | 3.1 | Resin | silicon case (option) |
LZCG530-10 | 30-600A | ≤20VA | φ45 | φ45 x φ120 x 65 | 5 | Resin | silicon case (option) |