Constant Temperature and Humidity Test Chamber Testing Machine Instrument for Lab Ga-2001-408L

Price $3000.00 Compare
Min Order 1 Piece
Shipping From Hunan, China
Popularity 451 people viewed
Quantity
+-
 

Hunan Gonoava Instrument Co Ltd

VIP   Audited Supplier 1 year
Profile Certified by SGS/BV
GA-2001-408L
Online
1 Year
400kg
GONOAVA
Plywood Case
1080 *1300*1750mm
China
9024800000
Product Description
Constant Temperature And Humidity Test Chamber Testing Machine Instrument for Lab GA-2001-408L
Design Standard:
GB11158 High Temperature Test Chamber Technical Condition
GB10589-89 Low Temperature Test Chamber Technical Condition
GB10592-89 High-low Temperature Test Chamber Technical Condition
GB/T10586-89Damp Heat Test Chamber Technical Condition
GB/T2423.1-2001Low Temperature Test Chamber Test Methods
GB/T2423.2-2001High Temperature Test Chamber Test Methods
GB/T2423.3-93Damp Heat Test Chamber Test Methods
GB/T2423.4-93Alternating Damp-Heat Test Methods
GB/T2423.22-2001 Temperature Changing Test Methods
IEC60068-2-1.1990Low Temperature Test Chamber Test Methods
IEC60068-2-2.1974High Temperature Test Chamber Test Methods
GJB150.3  High Temperature Test Methods
GJB150.4 Low Temperature Test Methods
GJB150.9 Damp Heat Test Methods
60068-2-1

Constant Temperature And Humidity Test Chamber Testing Machine Instrument for Lab GA-2001-408L
Uses:
This equipment can simulate different environment condition. It's appropriate for testing material performance, such as resist heat, resist dry,resist humidity and resist cold. That can define performance of material.

Parameters
1.Item
2.Model
Constant Temperature and humidity test chamber
408L
3.FunctionIt simulates the products in the chamber where the climate condition of different temperature and humidity, such as high-low operation and storage, temperature cycling, high-low temperature and high-low humidity, moisture condensation etc. to check its adaptability and changing performance.
It's required to conform to international regulation (IEC, JIS, GB, MIL…) to reach the consistency (including test schedule, condition, method) under the international standard.
4.Sample applicationThe chamber applies to:
compatibility test for store, transportation and application of electric, electronic products, unit components, parts and other materials under high or low temperature.
The following samples are prohibited to be tested and stored:
  • Inflammable , explosive and other volatile substances;
  • Corrosive substance;
  • Biont;
  • Strong electromagnetic emission source.
5.Volume, size & weight
5.1.Volume
5.2.Internal size
5.3.Exterior size
5.4.Weight
408L
W600*H850*L800mm
W1080 x H1300 x D1750mm
400KG
6.Performance
6.1.Test conditionTemperature:+25ºC, Humidity: ≤85%, no samples in the chamber
6.2.Test methodGB/T 5170.2-1996 Temperature test chamber
GB/T5170.5-1996 Temperature and humidity test chamber (only temperature and humidity)
6.3.Temperature range-40ºC→+150ºC (adjustable)
6.4.Temperature fluctuation±0.5ºC
6.5.Temperature accuracy distribution±2.0ºC
6.6.Humidity range20%~98%R.H (temperature at 20ºC-85ºC)
6.7.Humid. fluctuation±2.5%R.H.
6.8.Humidity accuracy distribution±3.0%.
6.9.Heat-up time-40ºC → +150ºC  Heat up for 2-4.0ºC/min
6.10.Cooling time +150ºC→ -40ºC   Cooling for 0.7-1.0ºC/min
6.11.Load conditionTesting space is not more than 3/4 of the total space, no heating
6.12.Sample holderStainless steel punching stencil
6.13.Relative humidity and temperature control range (refer to fig.)
6.14.Meet the technical standards



 
GB/T 2423.1-2001 Test A: Low temperature test method
GB/T 2423.2-2001 Test B: High temperature test method
GJB 150.3-1986  High temperature test
GJB 150.4-1986  Low temperature test
IEC68-2-1 Test A: Cold
IEC68-2-2 Test B: Dry heat
GB11158 "Technical Conditions for High Temperature Test Chamber "
GB10586-1 "Technical conditions for Damp heat test chamber "
GB/T 2423.2 "Basic environmental testing procedures 
for electric and electronic products B: High temperature test method".
GB/T 2423.3 "Basic environmental testing procedures 
for electric and electronic products Ca: Constant damp heat testing method" etc.
7.Structure characteristics.
7.1.Insulated enclosure structure
 
External material: SUS304 or stoving varnish
Inwall material: SUS304
Insulation material of box body: flame retardant fire rigid polyurethane foam
Door thermal insulation material: flame retardant fire rigid polyurethane foam
7.2.Air conditioning channel Centrifugal fan:
Heater, evaporimeter, outfall, temperature sensor
7.3.Test chamber standard
 
Window 330x450x40mm 3 vacuum layers
Anti-explosion handle
Door hinge: SUS #304
Lamps in the chamber: 11W
Access port: φ50mm or φ100mm 1pc or more.
7.4.Door
 
Single door, open from left, handle is at right; With viewing window: W300xH450mm, lamp window/condensation prevention thermal device
7.5.Controller Control screen, overtemperature protection setting
7.6.machine roomRefrigeration units , water pans , outfall
7.7.control cabinet for power distributionSwitchboard fan, ventilator
7.8.HeaterHeating system: cycling heating from finned-tube Stainless steel electric heater
7.9.HumidifierOven humidification system, cycling winding system
7.10.Power line hole and outfall positionlocated at the back of chamber
8.Cooling system (Binary cascade refrigeration)
8.1.Cooling compressor



Tecumseh (France)
8.3. Evaporator
fins-tube evaporator
8.4. Condensator


Air-coolled tube-type condensator  
8.5 Expansion systemRefrigeration system of volume control (capillary)
8.6 Evaporative condenserStainless steel brazing plate-type heat exchanger
 

 
8.7 Chiller control
 
Operation of cooling machine can be adjusted automatically by control system according to the test condition
evaporating pressure adjustable valve
Cooling loop of compressor
8.8 Freezing medium

 



R404a (Eco-friendly, Ozone loss rate at 0)
9  Controller
 




Independent R&D software (Taiwan)
9.1 Temperature and Humidity controllerImported 7.0 inch LCD touch screen control, programmable of temperature and humidity; 100 groups of program and 1000 groups of memory, each for 99hrs 59min and can be set as required with groups of PID control function.
9.2 Controller specificationsPrecision: Temp. ±0.1ºC+1digi, humid.: ±1%R.H+1digit
Distinguishability: Temp.: ±0.01ºC, humid.:±0.1%R.H.
slope temperature; 0.1~9.9 adjustable.
With warning function and up& down limitation standby
9 groups of PID control parameters and PID auto-calculation.
Dry and damp ball with auto correction.
9.3 Function of page display, program volume and control function-Touch screen operation, no need to input by key pressing;
-Temp. and Humid. Set (SV) with true (PV) value shown.
-Display of current program No., phase, time left and cycling times.
-Run the operation of accumulative time.
-Program set value of Temp.& humid. shown as curve;
-At least 5 phase of temp. & humid, time can be input on the sole program editing page.
-Language can be switched between English and Chinese;
-Fault page shown;
-Back light adjustable of screen;
-Protection function can be set by time, TIMER can be turn off by manual;
-Program groups available: 100 max. PATTEN.
-Memory volume available: 1000 SEGMENTS.
-Repeat executive command: up to 90 times for each command.
-Program with editing, cancel and insert available;
-Time set of SEGMENTS: 0~90Hour59Min;
-Module device controlled by program;
-Electricity cut memory, with auto start-up and executive program function after switch on;
-program execution with display of curve diagram;
-With auto adjustable freeze function;
-Reservation of start-up and turn-off available;
-Data and time adjustable;
-Key-pressing and page lock (LOCK) available.
10Safety protection device
a) Cooling system
  • compressor overheated
  • compressor overflowed
  • compressor overpressed
  • condensate fan overheated
  • oil pressure protection of compressor
b)Test chamberAdjustable overheat
Air conditioning channel overtemperature limit
Wind motor overheated
c)Other
  • phase sequence and open phase protection of main power supply
  • leakage protection
  • heating, humidification and Dry burning-resistant protection
  • overload and short circuit protection
  • overtemperature outage protection
11Other equipped parts
a)power control contactor of sample testingContactor of relay control: within AC220V, 2A (contactor closed under normal running, when chamber stops or of malfunction, contactor open).
b)leakage breaker of main power supply AC380V, 50Hz+Grounding wire.
12Accessories
a)Power
(Standard)
Five core single-phase three-wire and 1piece of protection grounding wire (optional)
b)Access portφ50mm, φ80mm, φ100mm, φ120mm available according to your requirement and cab be customized on the premise that not affect the machine performance.
c)USB interface (Standard)All the history curve and history data can be downloaded from controller as Excel or JPG according to date.
d)Remote Control System  (optional)
13  TransportationThe chamber as a unitary to be transported
  1. Delivery size
  2. Weight
Max. size (package not included): refer to "exterior size"
Max. delivery weight (package not included): refer to "Weight"
14 Usage requirementsAssured by users as below requirements
14.1 Installation position- With leveling ground and good ventilation;
- No strong shock near the chamber;
- No strong electromagnetic field near the chamber
- No inflammable , explosive , corrosive material and dust
- Surrounding size for chamber operation and maintenance:
A: not less than 10cm
B: not less than 60cm
C: not less than 60cm
D: 225 type: not less than 80cm
408 type: not less than 90cm
1000 type: not less than 120cm
14.2 ConditionTemperature: 5ºC~30ºC
Humidity: ≤85%
Air pressure: 86kPa~106kPa
14.3 Tap water: only for damp heating equipment with pure water machineWater flow ≥200kg/h, pressure: 0.1Mpa ~ 0.25Mpa.
Tap water conforms to GB 5749-1985 drinking water standard; Remark: equipped with DN15 male adapter of pure water machine
14.4 Power supply condition






Total power
Max. current
Voltage
  • AC220V + Protection grounding
  • Voltage fluctuation range: AC(220±10%) V
  • Frequency fluctuation range: (50±0.5)Hz
  • Resistance of protection grounding wire less than 4Ω.
  • It's required to equipped with air or motive switch of corresponding capacities, which is also used only for the chamber

8.5 KW
13A
380V

Constant Temperature And Humidity Test Chamber Testing Machine Instrument for Lab GA-2001-408L
Configuration List 
NoNameModelBrand
1controllerE600Independent research and development
2AC contactor France
3Thermal relay France
4Solid state relayMEGIRChina
5Intermediate relay France
6Min YangMin YangTaiwan
7Time relayJia YangTaiwan
8Expansion valve Danish
9No fuse switchshilinTaiwan
10Push button switchritaTaiwan
11Liquid expansion gas switchRAINBOWKorea
12motoryizhengTaiwan
13Wind turbinesJianyuTaiwan
14Heat preservation materialfoam+Glass woolChina
15compressortaikangFrance
16Expansion valve core Danish
17condenserKeweiliChina Foshan
18evaporatorKeweiliChina Foshan
19oil separatorEmersonFrance
20heaterTaideTaiwan
21condensate fanMa er MotorChina haining
22refrigerating fluid R404A honeywellUSA
23refrigerant oilbingxiongUK
24water suction pumpsanjiaozhouChina Foshan
25Evaporation pressure regulating valve Danish
26Water level switchalephJapan
27Solenoid valve Danish

Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA