GA-2903
Online
1 Year
Gas Chromatography Machine
0.5
Electronic Load
Digital
0-100Kg
GONOAVA
Plywood Case
China
9024800000
Product Description
Lab High Accuracy TCD/FID/FPD/ECD detector gas Chromatograph gcms Gas chromatography Analyzers Mass Spectrometry
Characteristics
- Using the advanced 10/100m adaptive Ethernet communication interface and built-in IP protocol stack, the instrument can easily realize long-distance data transmission through Intranet and Internet of enterprises;It facilitates the erection of laboratory and simplifies the laboratory configuration and data management.
- Low instrument internal design process of three separate connection, can connect to the local processing, unit director and supervisor, you can easily make unit director and supervisor real-time monitoring instrument is running and analysis data;
- Low instrument equipped with built-in integration design return control chromatography workstation, get rid of the traditional data acquisition card processing, support up to 253 sets of chromatographic work at the same time, data processing and the chromatograph, reached the domestic leading level;
- The Modbus/TCP server built in the built-in integrated return control workstation can easily connect the analysis results to the DCS (distributed control system), and all parameters of the real-time return control chromatograph;
- The instrument adopts vacuum fluorescence display technology, high - end atmosphere and convenient interface operation.Have two operating languages in English and Chinese to meet different user needs;
- The instrument adopts the modular structure design, the design is clear, the replacement upgrade is convenient, protects the effectiveness of the investment;It can satisfy complex sample analysis, and it can be selected with many high performance detectors, such as FID, TCD, ECD, FPD and NPD.
- Can realize completely abandoned the traditional mechanical valve, pointer type pressure gauge mode!EPC technology is used to control gas path and improve the automation level of gas chromatography.
- The real gas road failure automatic protection, pressure flow detection automatic ignition, automatic fire extinguishing automatic key, automatic gas path opening, reached a key start;
- When the instrument is designed, it can easily complete the online analysis of the gas and liquid sample (with the sample parts).
- The system is designed for automatic sampler interface, convenient for automatic sampler and future upgrade.
Main Specification
Operation display | vacuum fluorescent display (using agilent technology) |
Temperature control area | 6 |
Low operating temperature | room temperature 4 ºC ~ 450 ºC, the incremental 1 ºC |
Precision | plus or minus 0.1 ºC |
Program heating order number | 8-16 (optional) |
Low Cheng Sheng rate | 0.1 ~ 50 ºC / min (ordinary);0.1 ~ 80 ºC / min (high speed) |
External events | 8 roads;Auxiliary control output 4 |
Type of sample | filling column, capillary injection sample, six-way valve gas injection, automatic head space sampling |
Number of detectors | 3 (maximum);(FID, TCD, ECD, FPD, NPD) |
| |
(2)Work mode of EPC and EFC: 2 types;Constant current mode, constant pressure mode | |
Work gas of EPC and EFC | 5 types;Nitrogen, hydrogen, air, helium, argon |
EPC, EFC cheng sheng | 4 |
Pressure | 0 ~ 0.6mpa;Flow 0 ~ 100sccm or 0 ~ 500sccm (air) |
Control accuracy of EPC and EFC | pressure 0.01 KPa;The flow rate of 0.01 SCCM |
Low pressure sensor | Accuracy:full range of plus or minus 2% reproducibility :< + / - 0.05 KPa |
temperature coefficient | < + / - 0.01 KPa / ° C range 0 ~ 0.3 MPa or 0 ~ 0.6 MPa; |
Flow sensor | accuracy full range of < 5% reproducibility:< + 0.5% (full range) range 0 ~ 500sccm(manual, automatic, needle automatic detection) optional |
Communication interface | Ethernet IEEE802.3 hydrogen flame ionization detector (FID) |
Detection limit | Mt is less than 3 x 10-12g/s (positive hexadecane - isooctane solution); |
Baseline noise | less than 5 x 10-14a |
Baseline drift | no more than 1 x 10-13a /30min |
Linear range | greater than 106 |
Highest use low temperature | 450 ºC or less thermal conductivity detector (TCD) |
The sensitivity | S is greater than 10000mV. Ml/mg (positive hexadecane - isooctane solution) (amplification 1, 2, 4, 8 times optional) |
Baseline noise | less than 10 mu V |
Baseline drift | no more than 30 mu v/30min |
Linear range | > 104 electronic capture detector (ECD) |
Detection limit | no more than 1 x 10-14g/s (propane hexa6-isooctane solution) |
Baseline noise | less than 0.03mV |
Baseline drift | no more than 0.2mv /30min |
Linear range | greater than or equal to 104 |
Source | 63Ni flame photometric detector (FPD) |
Detection limit | (S) less than 5 x 10-11 g/S;(P) is less than or equal to 1 x 10-12g/s (methyl parathion - anhydrous ethanol solution) |
Baseline noise | less than 0.03mV |
Baseline drift | no more than 0.2mv /30min |
Linear range | equal to 103 (S) 102 (P) nitrogen and phosphorus detector (NPD) |
The detection limit | (N) is less than or equal to 1 times 10-13g/s;(P) less than 5 x 10-14g/s (azobenz-malathion - isooctane solution) |
Baseline noise | less than 0.03mV |
Baseline drift | no more than 0.2mv /30min |
Linear range | greater than or equal to 102 (N) 103 (P) |
Lab High Accuracy TCD/FID/FPD/ECD detector gas Chromatograph gcms Gas chromatography Analyzers Mass Spectrometry