RoHS, CB, ISO9001, CE
R290
Air Source Heat Pump
41/7
75
-30c~45c
4kw-16kw
Inverter
Hotels,Clubs,Hospitals,Villas and etc
Wotech
Factory Standard
1050*410*950mm
China
84186120
Product Description
15-22kw R290 Full DC Inverter a+++ Air to Water Monoblock Heat Pump for Heating Cooling and Hot Water






Note:
1.Outdoor air temperature 7ºC DB,6ºC WB;EWT 30ºC,LWT 35ºC.
2.Outdoor air temperature 7ºC DB,6ºC WB;EWT 47ºC,LWT 55ºC.
3.Outdoor air temperature 20ºC DB,15ºC WB;EWT 15ºC,LWT 55ºC.
4.Outdoor air temperature 35ºC DB,24ºC WB;EWT 12ºC,LWT 7ºC.
5.The Specifications are subject to changes without notice.
6.Relevant EU Standards and Legislation:EN14511,EN14825
R290 is one of the best refrigerants available for mass production upto now: Negligible Global Warming Potential (GWP) and degradation time is considered in monthes, Zero ozone layer depletion potential (ODP); Permanent green, Less load for the same performance, Low energy consumption and higher efficiency.
*Comparison of refrigerant GWP values.






Features:
1.Hot water up to 75C,suitable for underfloor/radiator heating/fan coil
2.can work stable at ambient temperature -25C to 45C
3.E-Heater,diverter valve and water pump can be inclueded
4. A+++ Energy Rating Level
5.Full inverter system,Stable and efficient performance.
6.R290 System,environment friendly
7.Application Scope:Hotels,clubs,hospitals,villas and any place in need of air conditioning,heating and hot water
8.With Wifi App control
1.Hot water up to 75C,suitable for underfloor/radiator heating/fan coil
2.can work stable at ambient temperature -25C to 45C
3.E-Heater,diverter valve and water pump can be inclueded
4. A+++ Energy Rating Level
5.Full inverter system,Stable and efficient performance.
6.R290 System,environment friendly
7.Application Scope:Hotels,clubs,hospitals,villas and any place in need of air conditioning,heating and hot water
8.With Wifi App control





Market model | WW07VM | WW09VM | WW12VM | WW15VM | WW20VT | WW22VT | ||
Heating1 A7 W35 | Output Capacity | kW | 2.84~7.20 | 3.61~9.17 | 4.75~12.06 | 5.83~14.80 | 8.03~20.38 | 8.71~22.12 |
Input Power | kW | 0.51~1.58 | 0.67~2.07 | 0.87~2.67 | 1.09~3.36 | 1.50~4.62 | 1.66~5.09 | |
COP | - | 4.56~5.52 | 4.43~5.36 | 4.51~5.46 | 4.40~5.32 | 4.41~5.34 | 4.35~5.26 | |
Input Current | A | 2.35~7.23 | 3.08~9.47 | 3.98~12.24 | 5.01~15.39 | 2.69~8.27 | 2.96~9.10 | |
Heating2 A7 W55 | Output Capacity | kW | 2.60~6.83 | 3.27~8.60 | 4.51~11.88 | 5.41~14.24 | 7.49~19.72 | 8.29~21.82 |
Input Power | kW | 0.72~2.24 | 0.94~2.91 | 1.26~3.92 | 1.57~4.88 | 2.08~6.44 | 2.41~7.47 | |
COP | - | 3.05~3.60 | 2.96~3.49 | 3.03~3.58 | 2.92~3.45 | 3.06~3.61 | 2.92~3.45 | |
Input Current | A | 3.30~10.25 | 4.28~13.30 | 5.78~17.94 | 7.19~22.32 | 3.71~11.53 | 4.30~13.37 | |
Heating3 A20 W55 | Output Capacity | kW | 3.54~8.86 | 4.47~11.19 | 5.98~14.95 | 7.16~17.91 | 10.03~25.07 | 10.71~26.77 |
Input Power | kW | 0.69~2.01 | 0.88~2.57 | 1.15~3.38 | 1.40~4.11 | 1.96~5.72 | 2.13~6.24 | |
COP | - | 4.41~5.16 | 4.36~5.10 | 4.43~5.18 | 4.36~5.10 | 4.38~5.12 | 4.29~5.02 | |
Input Current | A | 3.14~9.19 | 4.01~11.74 | 5.28~15.45 | 6.43~18.80 | 3.50~10.24 | 3.82~11.16 | |
Cooling4 A35 W7 | Output Capacity | kW | 2.11~5.02 | 2.95~7.03 | 3.83~9.12 | 4.45~10.59 | 5.90~14.05 | 6.38~15.20 |
Input Power | kW | 0.67~1.89 | 0.98~2.76 | 1.30~3.65 | 1.58~4.45 | 1.98~5.58 | 2.24~6.31 | |
EER | - | 2.65~3.13 | 2.55~3.01 | 2.50~2.95 | 2.38~2.81 | 2.52~2.97 | 2.41~2.84 | |
Input Current | A | 3.09~8.67 | 4.49~12.62 | 5.94~16.70 | 7.25~20.36 | 3.55~9.97 | 4.02~11.28 | |
Power Supply | V/PH/HZ | 220-240V/1/50Hz | 220-240V/1/50Hz | 220-240V/1/50Hz | 220-240V/1/50Hz | 380-415V/3/50Hz | 380-415V/3/50Hz | |
ErP level(35ºC) | - | A+++ | A+++ | A+++ | A+++ | A+++ | A+++ | |
ErP level(55ºC) | - | A++ | A++ | A++ | A++ | A++ | A++ | |
Water Side Heat Exchanger | - | Plate heat exchanger | Plate heat exchanger | Plate heat exchanger | Plate heat exchanger | Plate heat exchanger | Plate heat exchanger | |
Display controller | - | LCD touch screen | LCD touch screen | LCD touch screen | LCD touch screen | LCD touch screen | LCD touch screen | |
Backup heater (Optional) | kW | 3kW | 3kW | 3kW | 3kW | 3kW | 3kW | |
Expansion vessel | / | 3L | 3L | 5L | 5L | 5L | 5L | |
Refrigerant Type | - | R290 | R290 | R290 | R290 | R290 | R290 | |
Max Oulet Water Temperature | ºC | 75 | 75 | 75 | 75 | 75 | 75 | |
Working Ambeint Temperature | ºC | -25~43 | -25~43 | -25~43 | -25~43 | -25~43 | -25~43 | |
Water connection | inch | G1-1/4 | G1-1/4 | G1-1/4 | G1-1/4 | G1-1/4 | G1-1/4 | |
Sound pressure Level @1m | dB(A) | 50 | 50 | 52 | 53 | 58 | 58 | |
Net Dimension (L*W*H) | mm | 1085*440*840 | 1085*440*840 | 1150*430*960 | 1150*430*960 | 1150*430*1400 | 1150*430*1400 |
1.Outdoor air temperature 7ºC DB,6ºC WB;EWT 30ºC,LWT 35ºC.
2.Outdoor air temperature 7ºC DB,6ºC WB;EWT 47ºC,LWT 55ºC.
3.Outdoor air temperature 20ºC DB,15ºC WB;EWT 15ºC,LWT 55ºC.
4.Outdoor air temperature 35ºC DB,24ºC WB;EWT 12ºC,LWT 7ºC.
5.The Specifications are subject to changes without notice.
6.Relevant EU Standards and Legislation:EN14511,EN14825

R290 environmental refrigerant
R290 is one of the best refrigerants available for mass production upto now: Negligible Global Warming Potential (GWP) and degradation time is considered in monthes, Zero ozone layer depletion potential (ODP); Permanent green, Less load for the same performance, Low energy consumption and higher efficiency.*Comparison of refrigerant GWP values.

DHW tank disinfection
The DHW tank disinfection function is used to kill legionella by 65°C water to ensure the health and safety.

Climate curve
You can choose different climate correlation curves or your own customised curve. Once the curve is selected, the unit sets the outlet water temperature automatically according to the outdoor ambient air temperature.
Floor preheating and drying
Protect your home floor by activating the Floor Preheating function which slowly increases the heating temperature of the floor coils, avoiding possible floor damaging and transitioning smoothly to the heating function. The Floor Drying Up function provides an additional solution to the installer as it helps remove any residual moisture from newly installed floor coils, further protecting the installation and ensuring the optimal and effective operation of the heat pump.
Powerful heating with high efficiency
1. No capacity attenuation at -l0°C ambient temperature
2. Operation range down to -25°C
3. Maximum LWT reach 75°C
4. Energy efficiency level: A+++



Mode combination
There are 4 single operation mode (Cool,Heat,DHW,Auto) and 3combined operation mode to meet different demands of using.

Fast DHW
You can select the Fast DHW Function for the unit to produce DHW when there is a need for immediate hot water production.

Additional control
- Remote control for ON/OFFTBH,AHS
- Balance tank temperature sensor(field supplied)ensures accurate water temperature control