AHRI210/240 Air Conditioner Test laboratory
1.Synopsis of the Equipment
This equipment is for measuring the calories of Air-con. It also measures various kinds of data including pressure and electric properties of the Air-con. And it consists of indoor laboratory (1 room), outdoor laboratory (1 room), air handling unit, refrigerating machine, airflow meter, power panel, computer system and so on.
Type
Window type Air-con.
Split type Air-con.
Cassette type Air-con.
Floor standing type Air-con.
Fan coil unit
Capacity
Cooling capacity 9, 000BTU/h ~60, 000BTU/h (2, 250kcal/h~15, 000kcal/h).
Heating capacity 9, 000BTU/h ~60, 000BTU/h (2, 250kcal/h~15, 000kcal/h). Amount of dehumidify max.
15 L/h (indoor)
Water flow 0~4m3/h
Air flower rate (Indoor) 5~60m3/min(175~2, 100CFM)
Power 1 60~300V 40A continuous rating (at 230V).
3 60~600V 30A continuous rating (at 380V).
Size Indoor unit no bigger than W×D×H=1200×800×1900MM
Outdoor unit no bigger than W×D×H=1200×800×1200MM
Window unit no bigger than W×D×H=800×800×800MM
3.Inspection Conditions
Repeatability Test (by heater)
Test method ------will test 2 times at 3 grade.
Acceptable heater difference ----- 1.5% beneath.
Standard sample as compared with to test (by ETL unit).
Test method ------will test 3 times at 3 grade of ETL sample.
Acceptable heater difference ------±1.5% compared to ETL Test result.
For fan coil unit the balance between water side and air side ------5% beneath
Conditions other than these will match the temperatures established in the correlative standards and rules