Steam Autoclave Chemical Process Challenge Device Test Pack Type 5

Price $8.00 Compare
Min Order 50 Bags
Shipping From Guangdong, China
Popularity 488 people viewed
Quantity
+-
 

AQ Medical Technology Co., Ltd.

VIP   Audited Supplier 1 year
Profile Certified by SGS/BV
AQ2180W
Test Strips & Test Tube
Non-woven Fabric
Without Ethylene Oxide Sterilization
Two Years
Cssd
With Logo Printing
5
AQ
Carton
100pcs/box
China
Product Description


The Process Challenge Device(PCD) packs are used to monitor steam sterilization loads and can be used to release non implant loads.  The PCDs are designed for use in standard steam sterilizing processes, including 250° F (121°C) gravity steam, 270°F (132°) prevacuum
 

Each pack consists of a series of steam penetration and air removal barriers. A Class 5 integrator, as defined by EN ISO 11140-1, is located in the center of the barriers. The test pack is placed within the chamber of each load to be steam sterilized.
During processing, the sterilizer must remove or displace the air from the barrier material and replace it with steam throughout the pack. If a failure should occur, the indicator ink can assist in detecting steam quality issues based on the characteristics of the failure patterns of the indicator ink.
The Process Challenge Packs are manufactured in the absence of lead and heavy metals.

 
Monitors the validated sterilization parameters required to be delivered
World recognized standard
Provides immediate identification of failed loads
Documentation of successful sterilization cycles
Early identification of indicator application
Traceability and recognition of expired packs at time of use
Failure pattern aids in identifying root cause of cycle failure
No concerns over lead exposure or the toxicity of other heavy metals

 
Monitors all critical parameters of steam sterilization (time, temperature and steam quality)
One integrator indicator compatible with most steam sterilization cycles
Endpoint comparison is clear and unambigious
No concern of the toxicity of lead or other heavy metals exposure
 
Features
 
Class 5  integrator conforms to ANSI/AAMI/ISO 11140-1
Abrupt /distinctive total color change from yellow to blue/purple
Test sheet may be kept as a permanent record
Large indication of temperature and time with color specific coding
Lot number and expiration date on each pack
Ink pattern can assist in identifying steam quality issues
Manufactured in the absence of lead and heavy metals
 