BT-15KVA/12KW
Three Phase
On-line
Unbalanced Loads
Industry
Line Interactive UPS
Long-acting Machine
Medium Type
Bosin
310(Kg)
3 Phases 4 Wires,380V±25%
50Hz±10%
≥0.92
125%≥10 Min,150%≥20s
5:01
≥91%
Bosin
Wooden Case
CE, ISO
Shenzhen
85044020
Product Description
A). Pure sine wave output, flexible power solution design
B). Adopt 4 layer PCB, and SMD technology
C). High efficiency IGBT (insulated gate bipolar transistor) inverter technology
The 6th generation low-exhaust and big-power IGBT with excellent high speed switch feature, high voltage feature and large current feature. Drives by electric voltage, only need small control power. The 6th generation with lower saturation voltage, the inverter has high efficiency, low temperature, high reliability.
D). Touch screen display, with the simple operation and intuitive data, optional display language and logo
E). Set the work mode on the display directly, UPS mode, ECO mode, EPS mode
F). Intelligent detecting function
This system microprocessor can continuously detect power status online, the breaker status and all the working status of the circuit.
G). Premium load feature
It is completely capable to load from 0-100% while no need to change to bypass, which make sure the output reliable.
H). Cold start function
When mains failure, can directly use the battery to start the UPS until the battery discharge to low voltage, when mains recover, can self start UPS.
I). Generator compatible
According to the real electric circumstances, UPS can be compatible to the generator, highly improve the generator input efficiency, save the energy.
J). Intelligent communication
With RS232 and RS485 standard collocation, optional SNMP and dry contact
K). Perfect protection
Input/output over/low voltage protection, input surge protection, phase sequence protection, battery over charge/discharge protection, short circuit protection, over-temperature protection and so on, as well as alarm function.
L). Selectable battery inspection module
Can test the single parameter and display on the LCD, battery failure will immediately alarm and inform the administrator.
M). High-powered dynamic feature
Adopt kinds of feedback control such as instantaneous control mode and virtual value, not only reach the high dynamic adjustment, but also reduce the output voltage distortion.
N). Optional input harmonic filter or 12 pulse rectifier
Effectively restrain the input THD, raise UPS input power factor and reduce the input THD current.



B). Adopt 4 layer PCB, and SMD technology
C). High efficiency IGBT (insulated gate bipolar transistor) inverter technology
The 6th generation low-exhaust and big-power IGBT with excellent high speed switch feature, high voltage feature and large current feature. Drives by electric voltage, only need small control power. The 6th generation with lower saturation voltage, the inverter has high efficiency, low temperature, high reliability.
D). Touch screen display, with the simple operation and intuitive data, optional display language and logo
E). Set the work mode on the display directly, UPS mode, ECO mode, EPS mode
F). Intelligent detecting function
This system microprocessor can continuously detect power status online, the breaker status and all the working status of the circuit.
G). Premium load feature
It is completely capable to load from 0-100% while no need to change to bypass, which make sure the output reliable.
H). Cold start function
When mains failure, can directly use the battery to start the UPS until the battery discharge to low voltage, when mains recover, can self start UPS.
I). Generator compatible
According to the real electric circumstances, UPS can be compatible to the generator, highly improve the generator input efficiency, save the energy.
J). Intelligent communication
With RS232 and RS485 standard collocation, optional SNMP and dry contact
K). Perfect protection
Input/output over/low voltage protection, input surge protection, phase sequence protection, battery over charge/discharge protection, short circuit protection, over-temperature protection and so on, as well as alarm function.
L). Selectable battery inspection module
Can test the single parameter and display on the LCD, battery failure will immediately alarm and inform the administrator.
M). High-powered dynamic feature
Adopt kinds of feedback control such as instantaneous control mode and virtual value, not only reach the high dynamic adjustment, but also reduce the output voltage distortion.
N). Optional input harmonic filter or 12 pulse rectifier
Effectively restrain the input THD, raise UPS input power factor and reduce the input THD current.


Model name | BP-15K | |||||||
Rated power(w) | 12000 | |||||||
Input | Volt | 3 Phases 4 wires,380V±25% | ||||||
Frequency | 50Hz±10% | |||||||
Power factors | ≥0.92 | |||||||
Output | Volt | 3 Phases 4 wires,380V±25% | ||||||
Frequency | 50Hz±0.05% | |||||||
Harmonic wave distortion | Pure sine wave,Distortion rate <3%(linear load), <5%(Non-linear load) | |||||||
Unbalance volt | Balanced loading ≤1% ,Unbalanced loading≤3% | |||||||
Phase shift angle | Balanced loading≤1°,,Unbalanced loading≤3° | |||||||
Dynamic transient range | Output0~50%~100%≤3%,Recovering time≤10ms | |||||||
Overloading capability | 125%≥10 Min,150%≥20s | |||||||
Peak value factors | 5:01 | |||||||
Efficiency | ≥91% | |||||||
Swithing time | Pure on-line interactive with 0ms swithcing off | |||||||
Battery | Battery type | Free maintenance sealed lead-acid battery | ||||||
Battery volt(V) | 192V | |||||||
Charging method | PWM constant current constant voltage, Intelligent battery management system | |||||||
System information | system performance --MTBF | 300K hours | ||||||
Operating Environmental | Temp:-10~50ºC Relative humidity 0-93% No Operating altitude ≤3000m | |||||||
Supporting interface | Novell Netware Microsoft Windows9x Windows2000 Windows NT Linux | |||||||
Other features | Anti-moisture,Isolated invert transformer,Lightning surge absorption,Bypass manual switch | |||||||
Noise level | ≤53dB | |||||||
Unit size | 550×600×1135 | |||||||
(W×D×H)(mm) |