Biobase Double Channel Coagulometer Medical Blood Coagulation Analyzer

Price $580.00 Compare
Min Order 1 Piece
Shipping From Shandong, China
Popularity 292 people viewed
Quantity
+-
 

Biobase Biodustry (Shandong) Co., Ltd.

VIP   Audited Supplier 14 years
Profile Certified by SGS/BV
BK-CA02
Biological Diagnostics
Coagulation Analyzer
All
Semi-Auto Coagulation Analyzer
Bk-Ca02
2
4.3''
5
2
LED 470nm
Plasma
10000 Results Storage
20-40UL
Seconds,Ratio, %, G/L
37
Lower 85%
PT, Aptt, Fib Lower 5%
Lower 5%
BIOBASE
Standard Export Packing
290*260*135mm
China
Product Description
 
BIOBASE Double Channel Coagulometer Medical Blood Coagulation Analyzer
 
Product Description
Advantage:
 

.Parameters: PT, APTT, TT, FIB, etc.

.Principle: Clotting, optical method.

.Precise electronic pipette.

.Languages: English, French, Spanish, Portuguese, etc.

.Automatic start reagent addition.

.Thermal Printer, auto & manual print.

.LIS system availiable.

 

At present, the detection methods of thrombus/hemostatic components mainly include coagulation method, substrate chromogenic method, immunoassay, and latex agglutination method. It can be noted in the table that the most commonly used prothrombin time (PT), activated partial thromboplastin time (APTT), fibrinogen (FIB), thrombin time (TT), endogenous Coagulation factors, exogenous coagulation factors, high molecular weight heparin, low molecular weight heparin, protein C, protein S, etc. can be measured by coagulation method. Therefore, at present, semi-automatic blood coagulation instruments are basically mainly based on coagulation method, and in automatic blood coagulation instruments, there must also be coagulation method measurement.

Product Parameters

Model

BK-CA02

BK-CA04

Test Principle

Optical Colorimetry

Test Items

PT, APTT, TT, FIB

Test Channel

2 (can test different projects at the same time)

4 (can test different projects at the same time)

Wavelength

470nm

Detection Time

Normal sample detection time is 20 to 40 seconds, and can be set arbitrarily from 20 to 99 seconds

Sample Incubation Position

12

24

Reagent Incubation Position

5

6

Detection Position Temperature

37.0±1.0°C

Incubation Position Temperature

37.0±1.0°C

Incubation Time

1-999s

Reaction Time

1-99s

Reagent Dosage

Minimum dosage 20μl

Sample Volume

20μl~40μl

Display

5-inch high-definition color touch screen

Storage

20,000 results storage, automatically save measurement data when power off

Communication Interface

RS232 serial interface, support LIS system

Printer

Built-in thermal printer

Power Supply

AC100~240V, 50/60Hz

Consumption

70VA

Ambient Temperature

10ºC~30ºC

Relative Humidity

80%

Atmospheric Pressure

86kPa~106kPa

External Size (W* D*H)

360*210*120mm

390*250*135mm

Net Weight

3.5kg

4.96kg

Package Size (W* D*H)

376*246*316mm

445*305*265mm

Gross Weight

5Kg

7kg

Packing and Shipping

 

Company Profile

After Sales Service

Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA