XYD-RO-001
ISO9001
99.5%
Industrial, Commercial, Household
0.5t/H-20t/H
500L/Hour
200 Kg
1 Year
Reverse Osmosis Water Treatment Equipment
1400*680*1626mm
Household Purifier/ Commercial Purifier
C-Steel+PVC
Support 25-250 Peoples Use
Membrane, Pump
3kw-4.5kw
Provided
New YUDA
Wooden Box
RO Filtration
Guangxi, China
8421219090
Product Description
Reverse Osmosis Water Treatment Equipment

Product Model:RO 0.25/0.5/1/2/3/5/10T | ||||
Rated flow | 250L/h500L/h1000L/h2000L/h3000L/h5000L/h10000L/h | |||
Rated power | 1.1kw1.5kw2.1kw3.0kw8.5kw17.0kw | |||
Power supply | 220V/380V 50Hz | |||
Filtration level | Five-stage filtration(sand filter+carbon filter+scale inhebition+precision+reverse osmosis | |||
Applicable water quality | Municipal tap water | |||
Working pressure | 0.6-1.0MPa | |||
Inlet and outlet water diameter | based on actual device pervails | |||
Main host size | depends on different models |

Reverse Osmosis Water Treatment Equipment
- Muiti-stage filtration system (sand filter + carbon filter + precision + RO)
-Microcomputer intelligent control, real-time display of water quality status
- The equipment occupies a small area, reliable operation, and high quality water produced
-Pure physical filtration, high desalination rate
- Full 304 stainless steel frame, stainless steel canister, 304 stainless steel pipe
-Microcomputer intelligent control, real-time display of water quality status
- The equipment occupies a small area, reliable operation, and high quality water produced
-Pure physical filtration, high desalination rate
- Full 304 stainless steel frame, stainless steel canister, 304 stainless steel pipe





Introduction to System Functions
2.3. 1 Pre-treatment system
Pre-treatment is mainly to remove suspended solids, colloids, organic matter, etc. in the raw water to meet the feed water requirements of the reverse osmosis system, to ensure the normal operation of reverse osmosis. To ensure the normal operation of reverse osmosis. The pretreatment system includes multi-media filter, security filter and ancillary facilities.
2.3.1.1 Raw water pump
Reverse osmosis requires constant inlet flow rate and pressure to avoid fluctuations. At the same time, provide high flow of inlet water during the filter positive rinsing.
2.3.1.2 Multi-media filter
In order to intercept suspended solids, colloids and organic matter carried in the water for various reasons, and to adapt to the deterioration of water quality caused by seasonal changes in the raw water or unstable operation of the front-end process equipment, etc., a multi-media filter is installed after the raw water pump.
2.3.1.3 Dosing unit
The dosing unit can independently prepare and automatically mixing chemical agents. Its main function is to use programmatic methods to control the addition and mixing of chemical agents, in order to achieve the optimal mixing ratio and performance of the chemical agents.
2.3.1.4 Security filter
The security filter under high salt water conditions has a shell made of stainless steel material, and a tubular filter element such as PP melt blown, wire fired, folded, titanium filter element, and activated carbon filter element is used as the filtering element inside. Different filtering elements are selected according to different filtering media and design processes to meet the requirements of effluent water quality. Used for solid-liquid separation of various suspensions, with high environmental requirements and high filtration accuracy for pharmaceutical liquid filtration. It has a wide range of applications and is suitable for industrial fields such as medicine, food, chemical industry, environmental protection, and water treatment.
2.3.2 Single-stage reverse osmosis membrane modules
After pre-treatment, the raw water enters the reverse osmosis membrane modules. Under pressure, most of the water molecules and other trace ions pass through the reverse osmosis membrane and become the produced water after collection, which will be collected through the water production pipeline; Most of the salts, colloids, and organic matter in the water cannot pass through the reverse osmosis membrane and are trapped in concentrated water, which is discharged through a concentrated water pipeline.
2.4 System Control
This processing system adopts automatic control and can read the relevant process parameters of RO system through the touch screen, such as conductivity, pressure, etc.
Applications:
1.Different quality drinking water supply for the whole floor of enterprises and institutions
2.Drinking water supply for the entire floor of catering buildings such as teahouses, restaurants, restaurants, etc.
3.Quality drinking water supply for the entire floor of medical institutions such as large hospitals and clinics
4.School dormitories, teaching buildings, canteens and other campuses provide quality drinking water
5.Drinking water supply in public places such as railway stations and airports
6.Purified water supply for chemical plants, pharmaceutical plants, paint plants, etc.
7.Different quality drinking water supply for the entire floor of hotels, residential areas, etc.
8.Sea water desalination, water plant pure water production water.
2.Drinking water supply for the entire floor of catering buildings such as teahouses, restaurants, restaurants, etc.
3.Quality drinking water supply for the entire floor of medical institutions such as large hospitals and clinics
4.School dormitories, teaching buildings, canteens and other campuses provide quality drinking water
5.Drinking water supply in public places such as railway stations and airports
6.Purified water supply for chemical plants, pharmaceutical plants, paint plants, etc.
7.Different quality drinking water supply for the entire floor of hotels, residential areas, etc.
8.Sea water desalination, water plant pure water production water.