AC9004T45G
Three Phase Transducer, High Frequency Converter Transducer
Triple
Vector Control Transducer
PWM Control
Voltage
Low Voltage Variable-Frequency Drive
AC-DC-AC Variable-Frequency Drive
Voltage Variable-Frequency Drive
Simple Type, Elevator Special, Textile Special, Constant Torque Universal Type
Anchuan
45kw
380V
1 Year
Energy Conservation
ISO9001,Ce,CCC
Metal,Plastic
T/T/LC/D/P.
Within 15 Working Day
Box/Wooden Case
Approval
AnChuan
Client Requirement
600*385*265
China
8504409990
Product Description
Product Description
High Powered AC 380V 50-60Hz Three Phase 45kw Frequency Inverter with Ce Approval
The AC900 series inverter is a general high-performance current vector inverter designed to control and regulate the speed of a three-phase asynchronous/induction motor. AC900 adopts high-performance vector control technology, low speed and high torque output, with good dynamic characteristics and superior overload capability.

AC9004T45GB technical data:
AC drive model | Power capacity(kVA) | Input current A | Output current A | Adaptable Motor | |
AC9004T45GB | 69 | 92 | 91 | 45KW,60HP |
AC9004T45GB dimensions of appearance and mounting hole :
Model | Mounting Hole | Overall Dimension(mm) | Mounting hole Diameter(mm) | Weight(kg) | ||||
A | B | H | H1 | W | D | |||
AC9004T45GB | 260 | 580 | 549 | 600 | 385 | 265 | Φ10 | 32 |

AC drive | Power capacity(kVA) | Input current A | Output current A | Adaptable Motor KW. HP | |
Three-phase:380V,50/60HZ | |||||
AC900-4T0.75G | 1.5 | 3.4 | 2.1 | 0.75 | 1 |
AC900-4T1.5G | 3.0 | 5.0 | 3.8 | 1.5 | 2 |
AC900-4T2.2G | 4.0 | 5.8 | 5.1 | 2.2 | 3 |
AC900-4T3.0G | 5.0 | 8.0 | 7.0 | 3.0 | 4 |
AC900-4T4.0G | 5.9 | 10.5 | 9.0 | 4.0 | 5 |
AC900-4T5.5G | 8.9 | 14.6 | 13.0 | 5.5 | 7.5 |
AC900-4T7.5G | 11.0 | 20.5 | 17.0 | 7.5 | 10 |
AC900-4T11G | 17.0 | 26.0 | 25.0 | 11.0 | 15 |
AC900-4T15G | 21.0 | 35.0 | 32.0 | 15.0 | 20 |
AC900-4T18.5G | 24.0 | 38.5 | 37.0 | 18.5 | 25 |
AC900-4T22G | 30.0 | 46.5 | 45.0 | 22 | 30 |
AC900-4T30G | 40.0 | 62.0 | 60.0 | 30 | 40 |
AC900-4T37G | 57.0 | 76.0 | 75.0 | 37 | 50 |
AC900-4T45G | 69.0 | 92.0 | 91.0 | 45 | 60 |
AC900-4T55G | 85.0 | 113.0 | 112.0 | 55 | 70 |
AC900-4T75G | 114.0 | 157.0 | 150.0 | 75 | 100 |
AC900-4T90G | 134 | 180 | 176 | 90 | 125 |
AC900-4T110G | 160 | 214 | 210 | 110 | 150 |
AC900-4T132G | 192 | 256 | 253 | 132 | 175 |
AC900-4T160G | 231 | 307 | 304 | 160 | 250 |
AC900-4T200G | 250 | 385 | 377 | 200 | 300 |
AC900-4T220G | 280 | 430 | 426 | 220 | 300 |
AC900-4T250G | 355 | 468 | 465 | 250 | 400 |
AC900-4T280G | 396 | 525 | 520 | 280 | 370 |
AC900-4T315G | 445 | 590 | 585 | 315 | 500 |
AC900-4T355G | 500 | 665 | 650 | 355 | 420 |
AC900-4T400G | 565 | 785 | 725 | 400 | 530 |
Type | Terminal | Name | Function Description |
Power Supply | +10V-GND | External +10 V power supply | Provide +10 V power supply to external unit. Generally, it provides power supply to external potentiometer with resistance range of 1-5kΩ. Maximum output current:10mA |
+24V-COM | External +24 V power supply | Provide +24 V power supply to external unit. Generally, it provides power supply to DI/DO terminals and external sensors. Maximum output current:200mA | |
Analog Input | AI1-GND | Analog input 1 | Input voltage range: 0-10 VDC Impedance: 22kΩ |
AI2-GND | Analog input 2 | Input range: 0-10 VDC/0-20mA, decided by jumper J1 on the control board Impedance: 22kΩ (voltage input),500 Ω (current input) | |
Digital input | DI1- COM | Digital input 1 | Optical coupling isolation Impedance: 2.4kΩ Voltage range for level input: 9-30V |
DI2- COM | Digital input 2 | ||
DI3- COM | Digital input 3 | ||
DI4- COM | Digital input 4 | ||
DI5- COM | High-speed pulse input | Besides features of DI1-DI4, it can be used for high-speed pulse input. Maximum input frequency: 100 kHz | |
Analog output | AO1-GND | Analog output 1 | Voltage or current output is decided by jumper J2. Output voltage range: 0-10V Output current range: 0-20mA |
Digital output | DO1-COM | Digital output 1 | Optical coupling isolation, dual polarity open collector output Output voltage range: 0-24V Output current range: 0-50mA |
FM- COM | High-speed pulse output | It is limited by P5-00 (FM terminal output mode selection). As high-speed pulse output, the maximum frequency hits 100 kHz. As open-collector output, its specification is the same as that of DO1 | |
Relay Output | T/A-T/B | NC terminal | Contact driving capacity: 250VAC, 3A, COS ø=0.4 30VDC, 1A Applying to Overvoltage Category II circuit |
T/A-T/C | NO terminal | ||
Auxiliary interface | J3 | 485 communication | Jumper selection to decide whether to connect 330Ω matched resistor to make 485 communication |
J5 | External operation panel interface | Connect to external operation panel. |
It is used in dive automation production,involving wire drawing machine, film winding, coating machine, CNC machine tools, weaving machines, jacquard machines, fans, pumps, chemical fiber, textile, synchronous interaction, injection molding machines, lifting, elevator, machine tools, rolling mills, tube wire processing, lifting, lifting equipment, mill.

Packing and shipping:

Certificate

FAQ
Q:what's your delivery time?
A:3-5 working days for small order, 10-15 working days for big order.
Q:what's your warranty term?
A:we offer 24 months warranty time.
Q:Could you sell spare parts?
A if you are using our product.we can sell spare parts to you.but we couldn't sell the half-finished products.
Q:Can you make the inverter and soft starter control board(switchgear)?
A: YES,we have a lot of experience in design frequency inverter and soft starter cabinet according to your request,these items be produced by ourselves from our factory.
Q:How does your factory control the quality?
A:Quality is the priority, we always attach importance to quality control from the beginning to the end of production,every product will be fully assembled and carefully tested before packing and shipping.
Q:how can i trust you?
A our company has been audited and approved ISO9001,CE,CCC,Assessment report will be sent to you by Email.And we will take all the responsibility once problem during warranty time.
Contact us: