Nano Particle Size and Zeta Potential Analyzer

Price $36500.00 Compare
Min Order 1 Piece
Shipping From Shandong, China
Popularity 475 people viewed
Quantity
+-
 

Jinan Cyeeyo Instruments Co., Ltd.

VIP   Audited Supplier 5 years
Profile Certified by SGS/BV
CY-901
Balancing Machine
Dry Dispersion
1 Year
1-10000nm (Reference to Sample)
0.1mg/Ml--100mg/Ml
200ms/Cm (Reference to Sample)
Photomultiplier Tube
CYEEYO
Carton
75cm*65cm*70cm
Shan Dong
9027500090
Product Description
                                   

                                              Nano particle size and zeta potential analyzer

Overview:
CY-901 Nano Particle Size and Potential Analyzer is a new high-end dynamic light scattering particle size analyzer product launched by CYEEYO Particle Instrument Co., Ltd. which has dual testing capabilities of zeta potential and nano-particle size.
CY-901 uses electrophoretic light scattering technology to measure zeta potential and obtain isoelectric point. Compared with other instruments of the same type at home and abroad, it has significant advantages, and can be used in various experiments in conjunction with the laser particle size distribution analyzer.
Application:
CY-901 Nano Particle Size and Potential Analyzer has both zeta potential and nano particle size analysis and testing functions. It is suitable for particle size and surface potential measurement of a variety of different nanoemulsions, suspension colloids, etc. It can be widely used in fine chemical industry nanomaterials, R&D and production quality control of surfactants, oligomers, etc. It is also a product development and quality control testing instrument for inks, pharmaceutical preparations and other industries.

Main specification: 
Model No.CY-901
Executive standard GB/T 19627-2005/ISO 13321:1996 ;GB/T 29022-2012/ISO 22412:2008
Measure range1-10000nm (reference to sample)-500mV - +500mV
Concentration range0.1mg/ml--100mg/ml (reference to sample)
Electrophoretic mobility range> ±20μm.cm/V.s
Highest conductivity200mS/cm (reference to sample)
Accuracy error<1% (National standard sample D50 value)<10% (Standard sample)
Repeatability error<1% (National standard sample D50 value)<10%(Standard sample)
Laser SourceSemiconductor laser λ= 635nm,P=1-40mw (adjustable)
DetectorPhotomultiplier tube
Scattering angle90o18o
Sample cell volume10mm*10mm*40mm,   1--4mL10mm*10mm*60mm,   1mL
Temperate range5-45ºC
Temperature control accuracy0.1ºC
Test speed<5 Min
 Digital correlatorModelHA1024HA1024
Auto-correlation channels892892
Baseline channel4-
Physical channels5000 -
Unit delay time1µs-10ms(adjustable)1µs-10ms(adjustable)
Outer dimension560mm*450mm*300mm
N.W.20Kg

Main Features:
 
Test principleUsing the principle of electrophoretic light scattering and photon correlation spectroscopy, the size of particle Zeta potential was determined according to the electrophoretic movement speed of particles in liquid. The population velocity of the electrophoretic motion of the particles, and the amount of Doppler shift of the scattered light caused by the laser irradiation of these particles, varies. Photon correlation spectroscopy analyzes the size of particle Zeta potential according to the frequency shift.  
Ultra-high-speed data acquisitionThe core component of the instrument is through the HA1024 digital correlator, which can complete the collection of electrophoretic scattered light intensity and the calculation of the auto-correlation function in real time, so as to effectively reflect the information of the electrophoretic movement speed of the particles and lay the foundation for the accuracy of the Zeta potential test results.  
High sensitivity signal-to-noise ratioUsing professional-grade high-performance photomultiplier tubes, it has extremely high sensitivity and signal-to-noise ratio to photon signals.
High-precision constant temperature controlUsing semiconductor temperature control technology, the temperature control accuracy is as high as 0.1 °C, so that the sample is always in a constant temperature state during the whole test process, avoiding the test deviation caused by the change of liquid viscosity and Brownian motion caused by temperature changes, and ensuring the accuracy and stability of the test results.
 
Stable optical path systemThe optical path system constructed by the optical frequency shifting device and the optical fiber coupling technology makes the detection system not only small in size, but also has strong anti-interference ability, thus ensuring the stability of the test.
 




 