Dry Method Distribution Laser Diffraction Particle Size Analysis Analyzer Analyze

Price $13000.00 Compare
Min Order 1 Piece
Shipping From Shandong, China
Popularity 242 people viewed
Quantity
+-
 

Jinan Cyeeyo Instruments Co., Ltd.

VIP   Audited Supplier 5 years
Profile Certified by SGS/BV
CY-2012
Balancing Machine
Dry Dispersion
1 Year
ISO13320-1:1999, GB/T19077.1-2008, Q/Jwn001-2009
Mie Scattering Principle
<1% (National Standard Sample D50 )
High Performance He-Ne Laser (λ= 632.8nm
D10, D50, D90, D100, S/V Referent Parameters
<500mm
<900kg
>1000kn
0.5
Electronic Load
Dynamic Load
Needle
Computer Control
0-100kg
AC220V
CYEEYO
Carton
75cm*65cm*70cm
Shan Dong
9027500090
Product Description
            dry method Laser Distribution Particle Analyzer Tester
Product Description

 

Technique parameter

1,Measurement range:0.1-800 u m

2,Error:< ± 1% ( national standard materials D50)

3,repetitiveness deviation:< ± 1% ( national standard materials D50)

4,Electrical requirement:AC 220 ± 10 V, 50 Hz, 200w

5,Dimensions:950 X 330 X 300 mm

6,Weight:40 kg

Working Principle

   The Laser particle size analyzer accords to the international standards ISO-13320 and the Full range Mie Scattering Theory.  The data of particles are calculated from the changes of scattering luminous intensity of different particles in different angles in consideration of the refractive index of the particles and dispersion medium.

The data of particles are calculated in two ways:  unconstrained fitting inversion and constrained fitting inversion.

   The constrained fitting inversion is a relatively simple way. The particle size distribution is inverted in the assumed rule of the particles. But the deviation exists between the assumption and reality, and the tested results through the constrained fitting inversion can not really reflect the true size distribution of the particles.

   In unconstrained fitting inversion way, no particles are assumed before the test, and the size distribution of the dust clusters is precisely calculated directly from the luminous intensity. In this way, the instrument requires high performance, reasonable sensor design and size grading. The particle size distribution are precisely calculated with Rise Laser particle size analyzer which uses the optimized  non-uniform cross 3D  fan shaped sensor array and the reasonable size.

Technical characteristics

  Basis of the stable test: The stability of the tested data is ensured by the stable optical signals from the system. The Rise Laser particle size analyzer uses He-Ne gas laser light source of 0.6328 micron wavelength. It works to offer stable laser source signals, and serves more than 25000 hours.

   

 

Specifications

 

Dispersion method

Specifications

Dimensions

Weight(Net)

CY-2002

Wet

1,measurement range:0.1-800μm

2,Error:1%(national standard materials D50)

3,Repetitiveness deviation: 1%(national standard                       materials D50)

1000×330×320mm

38kg

CY-2006

Wet

1,Measurement range:0.05-1200μm

2,Error:1%(national standard materials D50)

3,Repetitiveness deviation: 1%(national standard materials D50)

CY-2008

Wet

1,Measurement range:0.02-2000μm

2,Error:1%(national standard materials D50)

3,Repetitiveness deviation: 1%(national standard materials D50)

CY-2009

Wet

1,Measurement range:0.02-2600μm

2,Error:1%(national standard materials D50)

3,Repetitiveness deviation: 1%(national standard materials D50)

 

 

CY-2012

Dry

       1,Measurement range:0.1-800μm

        2,Error:1%(national standard materials D50)

3,Repetitiveness deviation: 1%(national standard materials D50)

Main system: 1000×330×320mm

Dry sampling system:350×330×300mm

40kg

CY-2016

Dry

1,Measurement range:0.1-1200μm

       2,Error:1%(national standard materials D50)

3,Repetitiveness deviation: 1%(national standard materials D50)

CY-2018

Dry

1,Measurement range:0.1-2000μm

        2,Error:1%(national standard materials D50)

3,Repetitiveness deviation: 1%(national standard materials D50)

CY-2019

Dry

1,Measurement range:0.1-2600μm

        2,Error:1%(national standard materials D50)

3,Repetitiveness deviation: 1%(national standard materials D50)

CY-2022

Wet/

Dry

1,Measurement range:0.1-800μm/

2,Error:1%(national standard materials D50)

3,Repetitiveness deviation: 1%(national standard materials D50)

Main system: 1000×330×320mm

Dry sampling system:350×330×300mm

Wet sampling system:350×330×300mm

 

50kg

CY-2026

Wet/

Dry

1,Measurement range:0.05-1200μm(wet)

0.1-1200μm(dry)

2,Error:1%(national standard materials D50)

3,Repetitiveness deviation: 1%(national standard materials D50)

CY-2028

Wet/

Dry

1,Measurement range:0.02-2000μm(wet)

0.1-2000μm(dry)

2,Error:1%(national standard materials D50)

3,Repetitiveness deviation: 1%(national standard materials D50)

CY-2030

Wet/

Dry

2,Measurement range:0.02-2600μm(wet)

0.1-2600μm(dry)

2,Error:1%(national standard materials D50)

3,Repetitiveness deviation: 1%(national standard materials D50)

 

 

Packaging & Shipping

Our Advantages

FAQ

 

Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA