Industrial Genset 1800kw 2500kVA Containerized Yuchai Diesel Generator for Construction Backup

Price $200000.00 Compare
Min Order 1 SET
Shipping From Fujian, China
Popularity 339 people viewed
Quantity
+-
 

Mecca Power Co., Limited

VIP   Audited Supplier 7 years
Profile Certified by SGS/BV
MC
Responsible
12 Months or 1200 Operation Hours
Self-Starting Diesel Generator
Fixed
Four Stroke
Water Cooling
AC Three Phase
Low Speed
Land Use
Common Units, Standby Unit, Emergency Crew
Automation Type
Static Exciter
Chinese Yuchai
Stamford / Leroy Somer /Mecc Alte
UK Deepsea, Smartgen, Optional
Three Phase Generator Price
Silent Sound Proof/Weather Proof/Anti-Rusted Proof
50Hz/60Hz, 1500rpm 1800rpm
110-480V, 3.3kv-13.8kv Medium High Voltage
Mining/Construction/Data Center/Oil Gas
Commercial/Power Plant/Factory/Industrial
Spare Parts Documents
Mech/Elec/ECU/Ecm/Adec/Hpcr
Industrial Power Generator Set
CE, ISO, OEM Authorization etc.
Power Genset Unit
Electrical Diesel Generating Set
Mecca
Both Standard Marine Packing or Compact Packing.
As below Spec. with details
China
85021
Product Description
Mecca Power, with self-owned factory assets, independent R&D team, complete infrastructure equipment, provides a professional solution for the design, production and application support of intelligent generator sets with a broad and diverse range of gen-set power products that can operate independently, paralleled, on-site or remotely controlled.

As a prestigious OEM, we maintain a sound relationship with our main material suppliers, such as Cummins, Perkins, Deutz, MTU, Doosan, FPT,Mitsubishi,Stamford, Leroy Somer, Mecc Alte, Deepsea, ComAp, etc. Strongly focused on innovation and technical service, Mecca Power has been successfully used in hundreds of projects, widely applied in buildings, constructions, Telecom, data centers, mining,power plant, etc., covering over 90 countries in Asia, Africa, Oceania, Europe, Middle East and America.


Generator Introduction

MECCA-2500KVA 40HQ Containerized Yuchai Generator

This cutting-edge generator is ready to deliver unmatched performance and reliability for all your energy needs. Perfect for large-scale operations, this unit ensures continuous power with efficiency and durability.

Specification
Powered by YUCHAI                                                                                                   50HZ  220-440V  31-4510KVA 
ModelLTPPRPEngine GOV.
KVA / KW KVA/KW ModelOrigin
MC31YC31 25 29 23YCV2.5N35-G20CNE
MC41YC41 33 38 30YCV2.5T45-G20CNE
MC52YC53 42 48 38YCV2.5T55-G20CNE
MC55YC55 44 50 40YCD4.2N60-G20CNE
MC83YC83 66 75 60YCD4.2T90-G20CNE
MC96YC96 77 88 70YCA4.8T100-G20CNE
MC106YC106 85 96 77YCA4.8T110-G20CNE
MC138YC138 110 125 100YCA4.8TAA140-G20CNE
MC165YC165 132 150 120YCA4.8TAA180-G20CNE
MC165YC165 132 150 120YCB6.9TAA180-G20CNE
MC190YC190 152 173 138YCB6.9TAA205-G20CNE
MC226YC226 181 206 165YCA7.3TAA245-G20CNE
MC261YC261 209 238 190YCQ7.5260-G30CNE
MC261YC261 209 238 190YCMK10TAA285-G20CNE
MC323YC323 259 294 235YCMK10TAA350-G20CNE
MC386YC386 309 351 281YCMK10TAA420-G20CNE
MC459YC459 367 418 334YCMJ12TAA500-G20CNE
MC503YC503 402 456 365YCMJ12540-G30CNECU
MC551YC551 441 501 401YCT16TAA600-G20CNE
MC606YC606 485 551 441YCT16TAA660-G20CNE
MC606YC606 485 551 441YCT16660-G31CNECU
MC715YC715 572 650 520YCTD20780-G31CNECU
MC770YC770 616 701 561YCTD20840-G31CNECU
MC831YC831 665 756 605YCTD20900-G31CNECU
MC919YC919 735 835 668YCTD201000-G30CNECU
MC984YC984 787 894 715YCTH281070-G31CNECU
MC1121YC1121 897 1019 815YCTH281220-G31CNECU
MC1210YC1210 968 1100 880YCTH281320-G31CNECU
MC1210YC1210 968 1100 880YCC401320-G31CNECU
MC1398YC1398 11181270 1016YCC401520-G31CNECU
MC1375YC1375 11001250 1000YCTD40TA1500-G30CNECU
MC1538YC1538 12301400 1120YCTD40TA1680-G30CNECU
MC1678YC1678 13421525 1220YCTD40TA1830-G30CNECU
MC1850YC1850 14801681 1345YCTD40TA2000-G30CNECU
MC2090YC2090 16721900 1520YCTD52TA2270-G30CNECU
MC2313YC2313 18502100 1680YCTD52TA2510-G30CNECU
MC2481YC2481 19852256 1805YCTD52TA2700-G30CNECU
MC2481YC2481 19852256 1805YCC80TA2700-G31CNECU
MC2758YC2758 22062506 2005YCC80TA3000-G30CNECU
MC2758YC2758 22062506 2005YCC105TA3000-G31CNECU
MC3033YC3033 24262756 2205YCC105TA3300-G31CNECU
MC3308YC3308 26463006 2405YCC105TA3600-G31CNECU
MC3675YC3675 29403341 2673YCC105TA4000-G31CNECU
MC3859YC3859 30873508 2806YCC105TA4200-G30CNECU
MC4139YC4139 33113763 3010YCC105TA4500-G30CNECU
MC4510YC4510 36084100 3280YCC105TA4900-G30CNECU
Powered by YUCHAI                                                                                            60HZ  110-480V  31-2481KVA 
ModelLTPPRPEngineGOV.
KVA / KW KVA/KW ModelOrigin
MC31YC31 25 29 23YCV2.5N35-G21CNE
MC41YC41 33 38 30YCV2.5T45-G21CNE
MC53YC53 42 48 38YCV2.5T55-G21CNE
MC60YC60 48 55 44YCD4.2N65-G21CNE
MC76YC76 61 69 55YCD4.2T80-G21CNE
MC91YC91 73 83 66YCD4.2T100-G21CNE
MC121YC121 97 110 88YCB6.9T130-G21CNE
MC148YC148 118 134 107YCB6.9T160-G21CNE
MC193YC193 154 175 140YCB6.9TAA210-G21CNE
MC226YC226 181 206 165YCA7.3TAA245-G21CNE
MC262YC262 210 238 190YCMK10TAA285-G21CNE
MC330YC330 264 300 240YCMK10TAA360-G21CNE
MC386YC386 309 351 281YCMK10TAA420-G21CNE
MC475YC475 380 433 346YCMJ12TAA515-G21CNE
MC503YC503 402 456 365YCMJ12540-G33CNECU
MC551YC551 441 501 401YCT16TAA600-G21CNE
MC606YC606 485 551 441YCT16TAA660-G21CNE
MC715YC715 572 650 520YCTD20780-G33CNECU
MC770YC770 616 701 561YCTD20840-G33CNECU
MC864YC864 691 785 628YCTD20940-G32CNECU
MC935YC935 748 850 680YCTD201020-G32CNECU
MC984YC984 787 894 715YCTH281070-G33CNECU
MC1121YC1121 897 1019 815YCTH281220-G33CNECU
MC1238YC1238 990 1125 900YCTH281350-G33CNECU
MC1238YC1238 990 1125 900YCTD40TA1350-G32CNECU
MC1375YC1375 1100 1250 1000YCTD40TA1500-G32CNECU
MC1540YC1540 1232 1400 1120YCTD40TA1680-G32CNECU
MC1705YC1705 1364 1550 1240YCTD40TA1860-G32CNECU
MC1900YC1900 1520 1725 1380YCTD40TA2070-G32CNECU
MC2090YC2090 1672 1900 1520YCTD52TA2270-G32CNECU
MC2313YC2313 1850 2100 1680YCTD52TA2510-G32CNECU
MC2481YC2481 1985 2256 1805YCTD52TA2700-G32CNECU

MORE SPEC. CONTACT US...

Genset Workshop



FAQ

1.Q: What is your MOQ of this item?
A:1 Set

2.Q: What are your payment terms?
A:30% TT as deposit,70% TT before Shipment or 100% LC at sight

3.Q:What's the warranty time of diesel generators?
A:Global Warranty: 12months after delivery or 1000 running hours, whichever come first.

4.Q:Can you accept the customized products?
A:Yes, of course.We accept your specific order if you can provide us your special requirements or special samples

5.Q:What's the delivery time ?
A:20 to 35 days after receiving your payment in advance.

6.Q:Do you offer OEM service?
A: Yes

7.Q:What is the power range do you have?
A:Mecca Power assemble genset from 2 to 4000kva

8.Q:What's your special compare to other manufacturer?
A:We can delivery genset 1000units/month as engine and alternator OEM and Strategic partners. Especially for big quantity and big power projects, we support not only by solutions and tender documents, but also by fast delivery time and good price.



-----------------------------------------------------------------------------------------------MAINTENANCE---------------------------------------------------------------------------------------------

General Troubleshooting          

This section lists the generating set for some common fault, the reasons for the failure and determines the           
method of fault. General operators can determine their own fault and note, maintenance it according to the           
brochure. But please contact the repairing agents when meeting a special note or not listed failure of operation.           
Please remember the following suggestions before repairing:           
- Make sure that study the failure carefully before any operation.           
- Repair with the easiest way and most commonly used method.           
- Find the exact causes of failure and completely solve the fault.     
   

1. Generator Sets          
Description of this section is for reference only. If the following failure occurs please contact the repairing agents.           
(Some models of control panel installed only parts of the following warning indicator light)
IconIndicator LightReasonFault Analysis
Low oil pressure
alarm
Low oil pressure
alarm
When oil pressure does not
reduce normally, the light is on.
-General because of a lack of oil or lubrication
system failure caused by (refueling or replacing
the oil filter)
-When occurs this fault should automatically
shutdown generator sets immediately.
High water
temperature
alarm
High water
temperature
alarm
When the water temperature
has risen to a level higher than
or equal to the sensor setting,
the light is on.
-General because of a lack of water or oil
shortage, or overload.
-When occurs this fault should automatically
shutdown generator sets immediately.
Low fuel level
alarm
Low fuel level
alarm
When a fuel level has been
detected by the sensor fitted to
the daily tank, the light is on.
-General because of a lack of water or oil
shortage, or overload.
-When occurs this fault should automatically
shutdown generator sets immediately.
Battery charger
fault alarm
Battery charger
fault alarm
If the charging system has fault,
when engine running, the light is
off.
-Battery charging system fault caused.
-The light is on at the initial start, when the
charger reaches a certain speed, the light is off.
-This failure will not lead to automatic shutdown
generating units.
Crank failure
alarm
Crank failure
alarm
When the generator set failed
three times (or six times) in a
row starting, the light is on.
-Oil supply system or re-start the system failure
caused.
Overload or
breaker tripping
alarm
Overload or
breaker tripping
alarm
When overloading or Short
circuit, the light is on. Tripping
circuit breakers cause generator
set load out.
-In this fault, it need to load or unload some parts
to eliminate short-circuit, and then re-close the
circuit breaker.

Introduction of Maintenance grade(Interval) for the generator set 
A Level Maintenance Interval (Daily Maintenance)
1. Check Daily Report of Genset .
2. Check fuel level and coolant level. 
3. Check alternator for cracks or other damage, and the condition of the belts must be checked, flab or 
other damage.
4. Check the Air filter. The air filter should be replaced when necessary .
5. Release fuel tank and fuel filter's water and sediment.
6. Check the water cooling filter.
7. Check starting battery and electrolyte, add electrolyte when necessary. 
8. Check the starter, check noisy defect.
9. Use air syringe cleaner to clean the water tank, coolant system and cooled fin net.
B Level Maintenance Interval (Less than 400 hours)
1. Repeatedly check A Level Daily Maintenance steps.
2. After operating 100 to 250 hours, replace the fuel filter. All the fuel filters should not be cleaned, it 
should be replaced. 100 to 250 hours is just flexible time, actually it must be according to the practice 
and real fact. 
3. After operating 200 to 250 hours, replace the oil & oil filter. All the lube oil must fit up to the CF 
Grade of American Petroleum Institute.
4. After operating 300 to 400 hours, replace the air filter. The air filter can be cleaned with air syringe, or 
it can be replaced. The replacement must be according to the environment and real fact.
5. Replace the cooling system and add coolant concentration.
6. Clean the crankshaft and inlet, outlet air- filter net. 
C Level Maintenance Interval (2000-3000 hours), Please do as follows:
1. Repeatedly check A and B Level Daily Maintenance steps.
2. Remove the tap of valve, clean and wash oil dirt and sludge.
3. Fasten snails from each part (including running parts and fixed parts)
4. Clean and wash the crankcase, oil sludge, steel scraps and sediment with engine.
5. Check wearing of the engine turbo, clean and wash accumulation of carbon, adjust it when necessary.
6. Check and adjust valve clearance.
7. Check PT pump, quality of injection, adjust injection process, adjust it when necessary.
8. Check and adjust the tension of fan belt and water pump belt, adjust and replace it when necessary; 
clean and wash water tank radiator fins, then check the using capability of thermostat.
Current Repair (D Level Maintenance)(3000-4000 hours)
1. Check valve, valve seat and other wearing, repair or change it when necessary.
2. Check P pump, quality of injection, repair and adjust it when necessary.
3. Check and adjust connecting rod and fastening twisting torque.
4. Check and adjust valve clearance.
5. Check the trip of injector.
6. Check and adjust tension of fan and generating belt.
7. Clean and wash accumulation of carbon in inlet pipes.
8. Clean and wash the core of air cooler.
9. Clean and wash the whole oil lubrication system.
10. Clean and wash room of rocker arm, oil sludge in the sump and Metal scrap-iron.
Medium Repair (6000-8000 hours)
1. Including the items of minor repair.
2. Disassemble generator(except crankshaft)
3. Check the easy worn spare parts in pitman shaft system, gas distribution system, lubrication system, 
cooling system of cylinder, Piston, Intake and exhaust valve, replace them when necessary.
4. Check fuel supplying system, adjust oil pump and injector.
5. Repair and test the alternator, clean oil-sediment and lubricate the bearing of alternator.
Overhaul (9000-15000hours)
1. Including the items of intermediate repair.
2. Disassemble all the parts in the generator.
3. Replace cylinder, piston, piston loop, big and small bearing bushes, trusting pad of crankshaft, intake 
and exhaust valve, a whole set of tools for generator repair 
4. Adjust oil pump, injector and replace pump core, injector
5. Replace a whole set of repair tools for turbo charger and a repair set for water pump.
6. Adjust the parts of connecting rod, crankshaft and generator body,repair or replace them when necessary