1000kw 1250kVA Container Type Mtu Diesel Generator Set with 18V2000g26f Engine Generators for Rental/Powerhouse

Price $200000.00 Compare
Min Order 1 SET
Shipping From Fujian, China
Popularity 321 people viewed
Quantity
+-
 

Mecca Power Co., Limited

VIP   Audited Supplier 7 years
Profile Certified by SGS/BV
MC
Responsible
12 Months/1000 Hours Maintenance
Self-Starting Diesel Generator
Fixed
Four Stroke
Water Cooling
AC Three Phase
Low Speed
Land Use
Common Units, Standby Unit, Emergency Crew
Automation Type
Static Exciter
Mtu/Baudouin/Cummins/Perkins/Mitsubishi/Sme
Stamford/Leroy Somer/Marathon/Mecca, Optional
Deepsea/Comap/Datakom/Smartgen, Optional
Customized
Silent Sound Proof/Containerized/Open
50Hz/60Hz, 1500rpm 1800rpm
220-440V, 110-480V
3.3kv-13.8kv Generator
Prime Power/Standby Power/Continues Power
Data Center/Building/Power Plant/Construction
Tool Kit, General Introduction Manual
Global Service
CE, ISO, OEM Authorization etc.
Diesel Generator Sets
Mtu 2500kVA Generator
Mecca
Both Standard Marine Packing or Compact Packing.
As below Spec. with details
China
850211
Product Description
Mecca Power, with self-owned factory assets, independent R&D team, complete infrastructure equipment, provides a professional solution for the design, production and application support of intelligent generator sets with a broad and diverse range of gen-set power products that can operate independently, paralleled, on-site or remotely controlled.

As a prestigious OEM, we maintain a sound relationship with our main material suppliers, such as Cummins, Perkins, Deutz, MTU, Doosan, Mitsubishi,FPT,VOLVO,Stamford, Leroy Somer, Mecc Alte, Deepsea, ComAp, etc.

Strongly focused on innovation and technical service, Mecca Power has been successfully used in hundreds of projects, widely applied in buildings, constructions, Telecom, data centers, Mining, Power Plant,Oil Gas,etc., covering over 90 countries in Asia, Africa, Oceania, Europe, Middle East and America.

Product Description

Specification
Powered by  MTU                                                                                                                                                   50HZ  220-440 V 500-3600KVA 
ModelLTPPRPEngineFuel Cons.Cyl.Disp.Gov.
KVA / KW KVA/KW ModelOriginL/H(100%)L
MC880M880704 800640 12V2000G65CN184.012V23.9ADEC
MC1000M1000800 900720 16V2000G25CN210.016V31.8ADEC
MC1100M1100880 1000800 16V2000G65CN230.816V31.8ADEC
MC1250M12501000 1125900 18V2000G65CN264.516V31.8ADEC
MC1375M13751100 12501000 18V2000G26FCN261.118V35.8ADEC
MC1815M18151452 1650132012V4000G23FCN338.112V57.2ADEC
MC2021M20211617 1837.5147012V4000G63FCN373.112V57.2ADEC
MC2300M23001840 2087.5167016V4000G23FCN428.116V76.3ADEC
MC2475M24751980 2250180016V4000G63FCN465.516V76.3ADEC
MC2750M27502200 2500200020V4000G23FCN521.220V95.4ADEC
MC3080M30802464 2800224020V4000G63FCN567.520V95.4ADEC
MC3300M33002640 3000240020V4000G63LFCN610.520V95.4ADEC
MC500M500400 450360 10V1600G10FDE101.310V17.5ADEC
MC550M550440 500400 10V1600G20FDE110.910V17.5ADEC
MC660M660528 600480 12V1600G10FDE131.712V21ADEC
MC700M700560 644515 12V2000G25DE140.012V23.9ADEC
MC725M725580 660528 12V1600G20FDE144.912V21ADEC
MC1512M15121210 1375110012V4000G14RFDE307.612V57.2ADEC
MC1815M18151452 1650132012V4000G14FDE351.512V57.2ADEC
MC2020M20201616 1837.5147012V4000G24FDE398.212V57.2ADEC
MC2300M23001840 2087.5167016V4000G14FDE452.116V76.3ADEC
MC2500M25002000 2250180016V4000G24FDE491.616V76.3ADEC
MC2750M27502200 2500200020V4000G14FDE561.820V95.4ADEC
MC3080M30802464 2800224020V4000G24FDE611.620V95.4ADEC
MC3300M33002640 3000240020V4000G34FDE651.220V95.4ADEC
MC3600M36002880 3250260020V4000G44FDE653.020V95.4ADEC
Alternator Specifications
Alternator ModelSTAMFORD TAL/PI/UCI/HCI/LVI Series
Output power500kW-3600kW
Voltage controlAVR
Number of phase3
Power factor (Cos Phi)0.8
Insulation ClassH
Number of Wires 6
Protection23
Altitude ≤ 1000 m
Number of Pole 4
Exciter typeAREP
Voltage regulation±0.5%          
Totale Harmonic distortionat no load < 4 % - on load < 4 %
Bearing  Single
CouplingDirect
Alternator Data
♦ Operate either 50Hz or 60Hz.♦Stator grease insulation covered
♦ Standard enclosure IP23, but IP44, IP55 for option♦Rotator and excitation high polymer
♦ Insulation class H. ♦ Resist the corruption oil and acid
♦ Shunt excitataion systems.♦Rotator balance is in accordance with BS5625 
♦ AREP or PMG system for options. standard 12.5
♦ Automatic voltage regulator♦High-quality lubrication sealed long-time bearing
♦ Single bearing alternator♦Rotator silicon steel close tight
Standard Accessories
*Auto Control Panel*Starting Motor
*Main Ciruit Breaker*Exhaust silencer
*Fuel tank*Starting battery
*Base Frame*Float battery charger
*Filter *Flange
View more products click here...
Genset Workshop

FAQ

1.Q: What is your MOQ of this item?
A:1 Set

2.Q: What are your payment terms?
A:30% TT as deposit,70% TT before Shipment or 100% LC at sight

3.Q:What's the warranty time of diesel generators?
A:Global Warranty: 12months after delivery or 1000 running hours, whichever come first.

4.Q:Can you accept the customized products?
A:Yes, of course.We accept your specific order if you can provide us your special requirements or special samples

5.Q:What's the delivery time ?
A:20 to 35 days after receiving your payment in advance.

6.Q:Do you offer OEM service?
A: Yes

7.Q:What is the power range do you have?
A:Mecca Power assemble genset from 2 to 4000kva

8.Q:What's your special compare to other manufacturer?
A:We can delivery genset 1000units/month as engine and alternator OEM and Strategic partners. Especially for big quantity and big power projects, we support not only by solutions and tender documents, but also by fast delivery time and good price.



-----------------------------------------------------------------------------------------------MAITAINENCE---------------------------------------------------------------------------------------------

General Troubleshooting          

This section lists the generating set for some common fault, the reasons for the failure and determines the           
method of fault. General operators can determine their own fault and note, maintenance it according to the           
brochure. But please contact the repairing agents when meeting a special note or not listed failure of operation.           
Please remember the following suggestions before repairing:           
- Make sure that study the failure carefully before any operation.           
- Repair with the easiest way and most commonly used method.           
- Find the exact causes of failure and completely solve the fault.     
   

1. Generator Sets          
Description of this section is for reference only. If the following failure occurs please contact the repairing agents.           
(Some models of control panel installed only parts of the following warning indicator light)
IconIndicator LightReasonFault Analysis
Low oil pressure
alarm
Low oil pressure
alarm
When oil pressure does not
reduce normally, the light is on.
-General because of a lack of oil or lubrication
system failure caused by (refueling or replacing
the oil filter)
-When occurs this fault should automatically
shutdown generator sets immediately.
High water
temperature
alarm
High water
temperature
alarm
When the water temperature
has risen to a level higher than
or equal to the sensor setting,
the light is on.
-General because of a lack of water or oil
shortage, or overload.
-When occurs this fault should automatically
shutdown generator sets immediately.
Low fuel level
alarm
Low fuel level
alarm
When a fuel level has been
detected by the sensor fitted to
the daily tank, the light is on.
-General because of a lack of water or oil
shortage, or overload.
-When occurs this fault should automatically
shutdown generator sets immediately.
Battery charger
fault alarm
Battery charger
fault alarm
If the charging system has fault,
when engine running, the light is
off.
-Battery charging system fault caused.
-The light is on at the initial start, when the
charger reaches a certain speed, the light is off.
-This failure will not lead to automatic shutdown
generating units.
Crank failure
alarm
Crank failure
alarm
When the generator set failed
three times (or six times) in a
row starting, the light is on.
-Oil supply system or re-start the system failure
caused.
Overload or
breaker tripping
alarm
Overload or
breaker tripping
alarm
When overloading or Short
circuit, the light is on. Tripping
circuit breakers cause generator
set load out.
-In this fault, it need to load or unload some parts
to eliminate short-circuit, and then re-close the
circuit breaker.

Introduction of Maintenance grade(Interval) for the generator set 
A Level Maintenance Interval (Daily Maintenance)
1. Check Daily Report of Genset .
2. Check fuel level and coolant level. 
3. Check alternator for cracks or other damage, and the condition of the belts must be checked, flab or 
other damage.
4. Check the Air filter. The air filter should be replaced when necessary .
5. Release fuel tank and fuel filter's water and sediment.
6. Check the water cooling filter.
7. Check starting battery and electrolyte, add electrolyte when necessary. 
8. Check the starter, check noisy defect.
9. Use air syringe cleaner to clean the water tank, coolant system and cooled fin net.
B Level Maintenance Interval (Less than 400 hours)
1. Repeatedly check A Level Daily Maintenance steps.
2. After operating 100 to 250 hours, replace the fuel filter. All the fuel filters should not be cleaned, it 
should be replaced. 100 to 250 hours is just flexible time, actually it must be according to the practice 
and real fact. 
3. After operating 200 to 250 hours, replace the oil & oil filter. All the lube oil must fit up to the CF 
Grade of American Petroleum Institute.
4. After operating 300 to 400 hours, replace the air filter. The air filter can be cleaned with air syringe, or 
it can be replaced. The replacement must be according to the environment and real fact.
5. Replace the cooling system and add coolant concentration.
6. Clean the crankshaft and inlet, outlet air- filter net. 
C Level Maintenance Interval (2000-3000 hours), Please do as follows:
1. Repeatedly check A and B Level Daily Maintenance steps.
2. Remove the tap of valve, clean and wash oil dirt and sludge.
3. Fasten snails from each part (including running parts and fixed parts)
4. Clean and wash the crankcase, oil sludge, steel scraps and sediment with engine.
5. Check wearing of the engine turbo, clean and wash accumulation of carbon, adjust it when necessary.
6. Check and adjust valve clearance.
7. Check PT pump, quality of injection, adjust injection process, adjust it when necessary.
8. Check and adjust the tension of fan belt and water pump belt, adjust and replace it when necessary; 
clean and wash water tank radiator fins, then check the using capability of thermostat.
Current Repair (D Level Maintenance)(3000-4000 hours)
1. Check valve, valve seat and other wearing, repair or change it when necessary.
2. Check P pump, quality of injection, repair and adjust it when necessary.
3. Check and adjust connecting rod and fastening twisting torque.
4. Check and adjust valve clearance.
5. Check the trip of injector.
6. Check and adjust tension of fan and generating belt.
7. Clean and wash accumulation of carbon in inlet pipes.
8. Clean and wash the core of air cooler.
9. Clean and wash the whole oil lubrication system.
10. Clean and wash room of rocker arm, oil sludge in the sump and Metal scrap-iron.
Medium Repair (6000-8000 hours)
1. Including the items of minor repair.
2. Disassemble generator(except crankshaft)
3. Check the easy worn spare parts in pitman shaft system, gas distribution system, lubrication system, 
cooling system of cylinder, Piston, Intake and exhaust valve, replace them when necessary.
4. Check fuel supplying system, adjust oil pump and injector.
5. Repair and test the alternator, clean oil-sediment and lubricate the bearing of alternator.
Overhaul (9000-15000hours)
1. Including the items of intermediate repair.
2. Disassemble all the parts in the generator.
3. Replace cylinder, piston, piston loop, big and small bearing bushes, trusting pad of crankshaft, intake 
and exhaust valve, a whole set of tools for generator repair 
4. Adjust oil pump, injector and replace pump core, injector
5. Replace a whole set of repair tools for turbo charger and a repair set for water pump.
6. Adjust the parts of connecting rod, crankshaft and generator body,repair or replace them when necessary