1kv Teck 90 Multi-Conductor W/ Ground Aluminum Interlocked Armor Teck 90 Cable

Price $0.80 Compare
Min Order 1000 Meters
Shipping From Hebei, China
Popularity 248 people viewed
Quantity
+-
 

Hebei Huatong Wires & Cables Group Co., Ltd.

VIP   Audited Supplier 1 year
Profile Certified by SGS/BV
teck 90 cable
Construction, Underground, Industrial, Power Station
Low and Medium Voltage Cable
DC & AC
PVC
PVC
Round Wire
Bare Copper Wire
ISO, CCC, CE
PVC Cables
Rneda
RW90
2 3 4 5
Aluminum Alloy
600V 1000V 5kv
C-S-a C22 No. 131
Teck 90, Teck 90 Hl
The Us, Canada, Australia Ect
Power Cable
cUL
Copper or Aluminum
with or Without
RNEDA
Steel-Wooden Drum, Steel Drum
14AWG TO 1000MCM
China
8544492100
Product Description

Hebei huatong wires&cables Group Co.,ltd.

Largest cable manufacture in north China

19 years export experience

With UL,TUV,KEMA,CE,BV,PSB,SABS,GL,NK,KR,ABS ..products certifications

ISO9001,ISO14001,OHSAS18001 system certifications

With authorities testing report

CNAS approval laboratory 


 

TECK 90 CU 1000V NON-SHIELDED XLPE POWER CABLE

1000V, Non-Shielded, XLPE Insulation, FT4, -40°C, HL (Hazardous Locations), 90°C


Construction:

  1. Conductor:Class B stranded compressed copper in accordance with ASTM B3 and ASTM B8
  2. Insulation:XLPE (Cross Linked Polyethylene), Minimum Average Thickness: 4/0 = 0.08 inches (2.03 mm), 250 kcmil to 1000 kcmil = 0.090 inches (2.3 mm), 90°C
  3. Concentric Bonding Conductors:Class B, concentric bare copper wire serve
  4. Binder:Polypropylene Separator
  5. Inner Jacket:Black PVC, Minumum average thickness - 4/0 = 0.050" (1.27mm), 250 kcmil to 1000 kcmil = 0.060" (1.5 mm)
  6. Armor:Aluminum Interlocked Armour (AIA)
  7. Overall Jacket:Black PVC (optional colours available), Minimum Thickness: 4/0 to 400 kcmil = 0.050 inches (1.3 mm), 500 kcmil to 1000 kcmil = 0.060 inches (1.5 mm)

Applications and Features:

Single Conductor 1kV Teck 90 is a C-S-A approved armoured cable for Industrial and Commercial applications. FT4, -40C, HL, AG14 and 90°C rated for use in harsh Canadian environments. Rated for installation in cable trays, duct banks, direct burial, troughs, hazardous locations, continuous rigid cable supports, and concrete encaseable. CSA AG14 Acid Gas compliance.
  • -40°C - CSA Cold Bend and Impact Temperature
  • -25°C - Min. Installation Temperature
  • 90°C - Max. Continuous Operating Temperature
  • 140°C for Emergency Overload Temperature

Specifications:

  • ASTM B3 Standard Specification for Soft or Annealed Copper Wire
  • ASTM B8 Concentric-Lay-Stranded Copper Conductors
  • CSA C22.2 No. 131 Type TECK 90 Cable
  • CSA C22.2 No. 174 Cables in Hazardous Locations
  • CSA C22.2 No. 2556 & No. 0.3 Wire and Cable Test Methods
  • CSA LTGG [-40°C] - as per C68.10 - for Cold Bend and Impact rating
  • CSA HL - for Hazardous Locations rating
  • CSA SUN RES - for Sunlight Resistant rating
  • CSA AG14 - Acid Gas Compliance
  • ICEA S-96-659 (NEMA WC 71) 2001-5000 V Nonshielded Cables
  • IEEE 1202 FT4 Flame Test (70,000) BTU/hr Vertical Tray Test
  • FT1 Flame Test (1,706 BTU/Hr nominal - Vertical Wire Flame Test)

Sample Print Legend:

HT CABLES 3/C XX KCMIL CU TECK 90 XLPE -40{D}C FT4 AG14 SUN RES 90{D}C 1000V 



Message Type