1mm U Shape Glow Wire Loop for Glow Wire Test

Price $45.00 Compare
Min Order 1 Piece
Shipping From Guangdong, China
Popularity 296 people viewed
Quantity
+-
 

Shenzhen Bonad Instrument Co., Ltd.

VIP   Audited Supplier 9 years
Profile Certified by SGS/BV
iec60695
Good
One Year
Flammability Tester
Digital
Manual Control
Digital
Manual Control
Good
One Year
Flammability Tester
4.0 mm +/-0.04mm (Before Bending )
1mm/0.5mm
Chromium
1PCS
3-7days
Glow Wire Loop
for Glow Wire Test Apparatus
bnd
Safety Carton Box
iec60695
China
Product Description
1mm U Shape Glow Wire Loop for Glow Wire Test



Thermo resistance loop/glow wire loop, spare part set of Glow Wire Apparatus Acc IEC60695-2-10. Thermo resistance loop is a wire loop that is defined at a temperature and is pressed against a stan­dardized test platelet made of plastic
(or other materials) for a prescribed period of time under precise test condi­tions. The test examines whether the test specimen ignites, whether the flames propagate and whether burning material drips.

 
 
Specification:
1,Glow-wire material: Nickel/Chromium (>77%Ni/20±1%Cr)
2, Diameter: 4,0 mm ± 0,07 mm (before bending)
3, Dimension A: (after bending) see 5.1
 
Characteristics of Resistance:

 
MaterialNickel/Chromium(80/20) Alloy
Diameter of wire4mm Tolerance 0.04mm
Length80mm
Width between terminals36mm
Thermocouple fit0.55hole
ReferenceIEC60695-2-10 Figure 1
 
 
Appliance:
The tip of the glow-wire is then brought smoothly into contact with the test specimen for a duration of 30 s ± 1 s. An approximate rate of approach and withdrawal of 10 mm/s to 25 mm/s has been found to be satisfactory. However, the rate of approach shall be reduced to near zero upon contact to avoid impact forces exceeding 1,05 N. In those cases where the material melts away from the glow-wire, the glow-wire shall not be kept in contact with the test specimen. Following the application time, the glow-wire and the test specimen are slowly separated, avoiding any further heating of the test specimen and any movement of air which might affect the result of the test. The penetration of the tip of the glow-wire into and through the test specimen shall be limited to 7 mm ± 0,5 mm.
 
When forming the glow-wire , care shall be taken to avoid fine cracking at the tip.
 
 NOTE:
 Annealing is a suitable process for prevention of fine cracking at the tip.


 