JB-QB-LD128EN (M)
Fire Alarm Host
Cccf, CNAS, Lpcb, CE, CCS, ILAC-MRA
≥110dB
Canbus
Bus System
Electrionic Equipmentl
GQ
Standard Export Packing
GB
China
Product Description
Fire alarm controller (linkage type)




This linkage type fire alarm controller mainly to be used in middle and big size fire fighting project. It is the fire fighting master.
1. The capacity of this controller: 2 loops, the maximum number of the addressable codes are 512. One manual control panel (8 loops output, one of which is the output with the special purpose for the audio and video alarm).
2. Can match series micro-printer.
3. Can be interconnected with other building equipments through LD6900 series communication module (CANBus, RS232, RS485, Ethernet, telephone line, GPRS).
4. 128*64 LCD displays main information and content. The lamp indicating key state, convenient for operation.
5. Have the recording function (like black box), it can keep 1000 pieces fire alarm records, 1000 pieces gas extinguishing records and 1000 pieces of other notesrecords..
6. Take a record of the smoke/temperature output curve and data, addressing in simple method. Threshold value modified easily.
7. Peripheral equipments can be controlled directly through bus, and can also be controlled by the multilane manual panel.
8. With the function of loop short circuit protection and power supply short circuit protection.
9. Acting as supervision and alarm, it can monitor the alarm information of the on-scene leakage current, and it also can control the leakage current break automatically.
Main Technical Specifications:





This linkage type fire alarm controller mainly to be used in middle and big size fire fighting project. It is the fire fighting master.
1. The capacity of this controller: 2 loops, the maximum number of the addressable codes are 512. One manual control panel (8 loops output, one of which is the output with the special purpose for the audio and video alarm).
2. Can match series micro-printer.
3. Can be interconnected with other building equipments through LD6900 series communication module (CANBus, RS232, RS485, Ethernet, telephone line, GPRS).
4. 128*64 LCD displays main information and content. The lamp indicating key state, convenient for operation.
5. Have the recording function (like black box), it can keep 1000 pieces fire alarm records, 1000 pieces gas extinguishing records and 1000 pieces of other notesrecords..
6. Take a record of the smoke/temperature output curve and data, addressing in simple method. Threshold value modified easily.
7. Peripheral equipments can be controlled directly through bus, and can also be controlled by the multilane manual panel.
8. With the function of loop short circuit protection and power supply short circuit protection.
9. Acting as supervision and alarm, it can monitor the alarm information of the on-scene leakage current, and it also can control the leakage current break automatically.
Main Technical Specifications:
Content | Technical Data |
Primary power supply voltage | AC 220V (187V~242V) 50Hz |
Loop output voltage | DC 15V~20V |
Linkage output | 24V/4A |
Quantity of loops: | 2 loops |
Quantity of direct output joint records | 8 loops (include 1 loop of special output for audio and video alarm)active output. |
Maximum number of the bus equipment | 512 (addressable codes of each loop: 256) |
Maximum loop output current | 200 mA |
Maximum short circuit protection current | 400 mA |
Working ambient temperature | 0ºC~45ºC |
Storage temperature | Not lower than -40ºC |
Installation type | hanging |
Spare battery | 12V/14Ah (two piece) |
Weight | 11.2 Kg |