DRGX2108
20 feet (20,000-26,000 liters)
ISO Tank
Vacuum Insulation
Stainless Steel
Standard Tank Container
Globe Valve
8bar
36000kg
7100±3% Kg
6.058m * 2.438m * 2.591m
20′
20FT
Doer
Road, Sea, Railway or Their Intermodal Transportat
6.058M * 2.438M * 2.591M
China
8609001100
Product Description

Design code | ASME Boiler and Pressure Vessel Code Section VIII Division 1 -2023, App.44 | |
"International Maritime Dangerous Goods Code" (IMDG CODE), | ||
"Specification for insulated cargo tank for non-flammable cryogenic liquids" (CGA 341-2017), | ||
"Technical requirements and test methods for tank containers for liquids, gases, and pressurized dry bulk cargo" (ISO 1496-3:2019) | ||
Approval and Inspection Org. | LR | |
Type of Product | UN T75 ISO tank container | |
Container Model | 1CC | |
Rating Mass | 36000 kg | |
Maximum Allowable Filling Mass | 8505 kg | |
Tare Mass | 7100±3% kg | |
Allowable Stacking Weight | 213360 kg | |
Working Pressure | 8Bar | |
Length | 20′ | |
Frame Size | 20ft | |
Max. Allowable Working Pressure (MPa.) | Liquid container | 0.8 |
Outer jacket | -0.1 (Vacuum) | |
Min. Working Temperature | Liquid container | -162 °C |
Outer jacket | 20°C | |
Design Pressure (MPa.) | Liquid container | 0.95 |
Outer jacket | -0.1 | |
Design Temperature | Liquid container | -196 °C |
Outer jacket | 50 °C | |
The Main material | Liquid container | SA-240M 304 |
Outer jacket | SA-516M 485 | |
Frame | Q345E | |
Overall Size(Frame) /L*W*H/mm | 6058*2438*2591 | |
Media for this tank container | LNG | |
Painting | Primer + intermediate coat + topcoat (3 layers) | |
Color | Customized | |
Total Volume(L) | 21000 | |
Effective volume(L) | 18900 | |
Filling rate for this tank container | 90% | |
Static evaporation rate | ≤0.35% /d | |
Design service life | 20 years | |
Mode of transportation | Road, Sea, Railway or their intermodal transportation | |
Type of insulation | High vacuum multilayer insulation |
Technical Requirements
1. This frame tank container should carry out all kinds of the test according to the ISO 1496-3:2019. ISO 1496-3:2019.
2. Insulation materials shall meet the requirements of GB/T 31480 "High vacuum multilayer insulation materials for cryogenic vessels".GB/T 31480.
3. The accessories for this tank container shall meet the corresponding standards of product quality certification, which delivery from the factory in a complete set together with the tank body;
4. In order to meet the pressurization requirements of the ISO tank container, it is equipped with pressure build-up vaporizer to maintain the working pressure inside the tank.
5. The finished paint film on the outer surface of the ISO tank container is dense, firm and reliable, with a paint film thickness greater than 200mm, ensuring no fading for at least 3 years.
6. All supports of the connections between the tank and the frame should be thin welding, and welding firm and reliable, the weld seam surface shall not have cracks, undercut, stomatal, crater and splash.
7. The tank needs to be replaced with nitrogen before leaving the factory. Fill the interior of the liquid container with 0.03~ 0.05Mpa pressure nitrogen gas for protection. ,0.03~0.05Mpa.
8. All markings are in full compliance with applicable regulations and are affixed to be as smooth and flat as possible. Includes the required regulatory symbols, the unique identification numbers and logos of the tank owner.
9. Easy to use, it can be used as a mobile tank to transport liquids, and can also be used as a fixed tank to store liquids. This ISO tank container are widely used: in industry, it provides a stable oxygen source for oxidation and combustion processes in steel, chemical and other industries; in the medical field, it guarantees the supply of medical oxygen to hospitals, emergency centers, etc.
1. This frame tank container should carry out all kinds of the test according to the ISO 1496-3:2019. ISO 1496-3:2019.
2. Insulation materials shall meet the requirements of GB/T 31480 "High vacuum multilayer insulation materials for cryogenic vessels".GB/T 31480.
3. The accessories for this tank container shall meet the corresponding standards of product quality certification, which delivery from the factory in a complete set together with the tank body;
4. In order to meet the pressurization requirements of the ISO tank container, it is equipped with pressure build-up vaporizer to maintain the working pressure inside the tank.
5. The finished paint film on the outer surface of the ISO tank container is dense, firm and reliable, with a paint film thickness greater than 200mm, ensuring no fading for at least 3 years.
6. All supports of the connections between the tank and the frame should be thin welding, and welding firm and reliable, the weld seam surface shall not have cracks, undercut, stomatal, crater and splash.
7. The tank needs to be replaced with nitrogen before leaving the factory. Fill the interior of the liquid container with 0.03~ 0.05Mpa pressure nitrogen gas for protection. ,0.03~0.05Mpa.
8. All markings are in full compliance with applicable regulations and are affixed to be as smooth and flat as possible. Includes the required regulatory symbols, the unique identification numbers and logos of the tank owner.
9. Easy to use, it can be used as a mobile tank to transport liquids, and can also be used as a fixed tank to store liquids. This ISO tank container are widely used: in industry, it provides a stable oxygen source for oxidation and combustion processes in steel, chemical and other industries; in the medical field, it guarantees the supply of medical oxygen to hospitals, emergency centers, etc.