DSP-20ADZ
Air-Cooled
Air-Cooled,Direct Cooling
Integral
380V/50HZ
2
Ultra Low
for Manufacture
Precision Machine Tool
RoHS, UR, ISO, CE, CCC
New
More Than 10years
12 Months
1890*1250*1640
850
for Manufacture
DARREN
Standard Wooden Package
ISO9001, CE, SGS
Shanghai, China
8418692090
Product Description
As industrial chiller,this air cooled water chiller of box-type has the following feathers:
1. Cooling capacity:55.3kw
2. Normal conditions: Chilled waterinlet is 7 degrees, outlet temperature is 12 degrees. Ambient dry bulb temperature is 35 degrees.
3. Operating range: Chilled water inlet temperature 9~20 degrees.
4. Input power: 3P-380V-50Hz, Allowable fluctuate voltage: ± 10%, allowable voltage difference in phase: ± 2%.
5. Accept orders for special requirements.
6. Scroll hermetic compressor international brand-free maintenance.
7. Electrical elements and refrigeration components are used from world-renowned brand.
8. Industrial and durable design, with stainless steel water tank and high-lift pumps.
9. Wide range of variable chilled water temperature to meet the industrial requirements throughout whole year.
10. Designed as an independent refrigeration circuit, each compressor corresponding to one refrigeration circuit.
11. Friendly choose to use environmentally R407C or R134A refrigerant.





CHILLER, WATER CHILLER, AIR COOLED CHILLER
1. Cooling capacity:55.3kw
2. Normal conditions: Chilled waterinlet is 7 degrees, outlet temperature is 12 degrees. Ambient dry bulb temperature is 35 degrees.
3. Operating range: Chilled water inlet temperature 9~20 degrees.
4. Input power: 3P-380V-50Hz, Allowable fluctuate voltage: ± 10%, allowable voltage difference in phase: ± 2%.
5. Accept orders for special requirements.
6. Scroll hermetic compressor international brand-free maintenance.
7. Electrical elements and refrigeration components are used from world-renowned brand.
8. Industrial and durable design, with stainless steel water tank and high-lift pumps.
9. Wide range of variable chilled water temperature to meet the industrial requirements throughout whole year.
10. Designed as an independent refrigeration circuit, each compressor corresponding to one refrigeration circuit.
11. Friendly choose to use environmentally R407C or R134A refrigerant.





CHILLER, WATER CHILLER, AIR COOLED CHILLER
Type | DSP- | |||||||||||
03ASZ | 05ASZ | 08ASZ | 10ASZ | 12ASZ | 15ASZ | 20ASZ | 20ADZ | 25ADZ | 30ADZ | 40ADZ | ||
Refrigerant capacity | kW | 8.8 | 14.4 | 25.5 | 29.0 | 32.7 | 41.1 | 55.3 | 58.0 | 65.4 | 82.2 | 110.6 |
103kcal/h | 7.6 | 12.4 | 21.9 | 24.9 | 28.1 | 35.3 | 47.5 | 49.8 | 56.2 | 70.6 | 95 | |
RT | 2.5 | 4.1 | 7.3 | 8.2 | 9.3 | 11.7 | 15.7 | 16.5 | 18.6 | 23.4 | 31.5 | |
Compressor | Quantity (SET ) | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 2 | 2 | 2 | 2 |
Refrigeration input power (kW) | 2.6 | 4.3 | 7.0 | 7.9 | 8.9 | 12.4 | 16.6 | 15.7 | 17.9 | 24.9 | 33.3 | |
Operating current (A) | 4.5 | 8.0 | 12.3 | 13.8 | 16.0 | 22.7 | 28.8 | 27.6 | 32.0 | 45.4 | 57.7 | |
Condensation axial fan | Refrigeration input power (kW) | 0.19 | 0.30 | 0.60 | 0.90 | 0.90 | 0.90 | 1.35 | 1.35 | 1.80 | 1.80 | 2.70 |
Operating current (A) | 0.46 | 0.65 | 1.30 | 2.06 | 2.06 | 1.95 | 3.09 | 3.09 | 3.90 | 3.90 | 6.18 | |
Input power | kW | 3.1 | 5.1 | 8.3 | 9.5 | 11.3 | 14.8 | 19.5 | 18.6 | 21.2 | 28.9 | 38.2 |
Operating current | A | 5.8 | 9.9 | 15.2 | 17.5 | 21.3 | 28 | 35.2 | 34 | 39.2 | 54.2 | 68.7 |
Condenser | Type | Imported efficiency copper pipe and aluminum foil wing heat exchanger | ||||||||||
Evaporator | Type | Pipe dry high efficiency heat exchanger | ||||||||||
Cooling water flow (L/min) | 25 | 41 | 73 | 83 | 94 | 118 | 159 | 166 | 187 | 236 | 317 | |
Interface size | 25 | 25 | 40 | 40 | 40 | 50 | 50 | 50 | 65 | 65 | 65 | |
Chilled water pump | Type | High efficiency,low noise centrifugal water pump | ||||||||||
Input power (kW) | 0.37 | 0.55 | 0.75 | 0.75 | 1.5 | 1.5 | 1.5 | 1.5 | 1.5 | 2.2 | 2.2 | |
Head (mH20) | 16 | 21 | 22 | 19 | 17 | 25 | 24 | 24 | 23 | 22 | 21 | |
Safety devices | High &low voltage protection,current overload protection,antifreezing protection,electronical delay protection | |||||||||||
Nominal tank volume | L | 90 | 90 | 100 | 115 | 145 | 250 | 270 | 270 | 320 | 360 | 400 |
Overall size | Length (mm) | 850 | 850 | 1200 | 1350 | 1400 | 1600 | 1950 | 1950 | 2100 | 2200 | 2450 |
Width (mm) | 750 | 750 | 850 | 850 | 850 | 1000 | 1250 | 1250 | 1250 | 1250 | 1350 | |
Height (mm) | 1350 | 1350 | 1550 | 1550 | 1550 | 1600 | 1600 | 1600 | 1600 | 1850 | 2050 | |
weight | kg | 150 | 200 | 285 | 350 | 450 | 600 | 830 | 830 | 1050 | 1250 | 1350 |