DEM-NX
1 Year
1 Year
Digital
Direct Connected
Watt-Hour Meter, Meter for Industry and Home Use, Standard Electric Energy Meter, Prepayment Meter, Reactive Energy Meter, Multi-rate Watt-hour Meters, Maximum Demand Meter
Three-phase Three-wire
Electronic Meter
Terminal
Continuous Wave
Energy Meter
RoHS, ISO, CE
Customized
-20 ~+50
0-999999
Single Phase
Analog and Digital
177*133*118mm
2.0
220V
Blue Jay
Carton
10*10cm
Zhejiang, China
Product Description
19D-NX Modbus energy meter is Blue Jay's next-generation din-rail meter power meter. Using a 3M width expand model can build a max 40x3P4W or 120x1P2W energy metering system. A flexible selection of different modules can build the most suitable on-site integrated metering device. The 19D-NX din rail dc power meter uses CTs connect, and provides max 0.5 class metering accuracy. The default is RS485 Modbus-RTU port so it can be called an energy meter with RS485. Furthermore, the customized expand module of the 240v electric meter can provide extra IoT modules valid for different projects.
* 4M / 3M width size modular design
* 6'' dot matrix LCD screen
* Programmable digital inputs/outputs
* Precision metering & sub-billing
* Universal series power supply (85-265VAC/DC)
* Core unit provide 15W(12Vdc) drive capacity
* Core unit provide 15W(12Vdc) drive capacity
* Expand unit can separate use as metering node
* RS-485 Modbus/RTU Communications
* Optional Ethernet expand module
* Optional IoT expand module
* RS-485 Modbus/RTU Communications
* Optional Ethernet expand module
* Optional IoT expand module
Current measurement on inputs (TRMS) of the modbus energy meter | ||
Rating of CT secondary | 100mA, 50mA, 2.5mA | |
Measurement range | 0~11kA | |
Input consumption | <0.1kA | |
Accuracy | 0.5% (IEC61557-12) | |
Impedance | <10mΩ | |
Overload capacity | 1.2 times of rating, continuous | |
10 times of rating, 10s | ||
Voltage measurement (TRMS) of this 240v electric meter | ||
Measurement range | 18…300VAC | |
PT secondary | 100VAC/ 400VAC | |
Input consumption | <0.1VA | |
Accuracy | 0.5% (IEC61557-12) | |
Impedance | >1MΩ | |
Overload capacity | 1.2 times of rating, continuous | |
2 times of rating, 1s | ||
Frequency measurement | ||
Measurement range | 45…65Hz | |
Accuracy | ±0.02Hz | |
Energy accuracy | ||
Active energy | Class 1.0 (IEC 62053-22) | |
Reactive energy | Class 2.0 (IEC 62053-23) | |
Auxiliary power supply | ||
Rating | 12VDC | |
Consumption | <0.9W | |
Communication | ||
Link | RS485 (2/3 wires half duplex) | |
Protocol | Modbus RTU mode | |
MODBUS speed | 4800/9600 bauds | |
Safety | ||
Isolation withstand voltage | AC 1KV/ 1min |