Lead mode:                               5 -lead(R, L, F, N, C) (3/12 lead ECG for optional)
Lead selection:                         I, II, III, avR, avL, avF, V
Waveform:                       3 and 7 channel selectable
Gain selection:                       0.5mm/mv,1mm/mv,2mm/mv
Sweep speed:                        6.25mm/s;12.5mm/s;25mm/s;50mm/s
Heart rate range:                     Adult: 15~300bpm;
Neonate/pediatric: 15~350bpm
Accuracy:                                 +1bpm or +1%, which is greater
Resolution:                       1bpm
Filter:                                           surgery mode: 1~20Hz
Monitor model: 0.5~40Hz
Diagnostic mode: 0.05~130Hz
Scaling signal:                         1mv, +3%
Protection:                      withstand 4000VAC/50 voltage isolation against electrosurgical interference and defibrillation
Alarm range:                           15~350bpm
S-T segment detection:                
Measurement range:    2.0mV~+2.0mV                        
 Alarm Range:         -2.0mV~ +2.0mV
Accuracy:             -0.8mV ~+0.8Mv
Error:               +0.02Mv
 
Arrhythmia analysis:       YES 



Parameter Specification
 
ECG
Lead mode:                               5 -lead(R, L, F, N, C) (3/12 lead ECG for optional)
Lead selection:                         I, II, III, avR, avL, avF, V
Waveform:                       3 and 7 channel selectable
Gain selection:                       0.5mm/mv,1mm/mv,2mm/mv
Sweep speed:                        6.25mm/s;12.5mm/s;25mm/s;50mm/s
Heart rate range:                     Adult: 15~300bpm;
Neonate/pediatric: 15~350bpm
Accuracy:                                 +1bpm or +1%, which is greater
Resolution:                       1bpm
Filter:                                           surgery mode: 1~20Hz
Monitor model: 0.5~40Hz
Diagnostic mode: 0.05~130Hz
Scaling signal:                         1mv, +3%
Protection:                      withstand 4000VAC/50 voltage isolation against electrosurgical interference and defibrillation
Alarm range:                           15~350bpm
S-T segment detection:                
Measurement range:    2.0mV~+2.0mV                        
 Alarm Range:         -2.0mV~ +2.0mV
Accuracy:             -0.8mV ~+0.8Mv
Error:               +0.02Mv
 
Arrhythmia analysis:       YES
SPO2
Measurement range:       0~100%
Wave speed:              12.5mm/s;25mm/s
Resolution:               1%
Accuracy:                +2% (70-100%); 0-69% unspecified
Alarm range              0~100%
Lower perfusion situation
 
Pulse Rate(PR)
Range:                20~300bpm
Resolution:            1bpm
Error:                +1bpm or +2%, whichever is greater
 
NIBP
Method:                  Digital Automatic oscillometric
Operation mode :           Manual/Automatic
Auto measurement time:     Adjustable (1~720min)
                        (1,2,3,4,5,10,15,30,60,90,120,240,480,720min)
Measurement Unit:         mmHg/Kpa selectable
Measurement types:        Systolic, Diastolic, Mean 
Measurement Range:
Range of Systolic pressure:   Adult: 40~270mmHg
Pediatric: 40~220mmHg
Neonate: 40~135mmHg
Range of mean pressure:    Adult: 20~235mmHg
Pediatric: 20~165mmHg
Neonate: 20~110mmHg
Range of diastolic pressure:   Adult: 10~215mmHg
Pediatric: 10~150mmHg
Neonate: 10~100mmHg
Over-pressure protection:    Double safety protection
Resolution:                1 mmHg
Alarm:                    Systolic, Diastolic, and Mean
 
RESPIRATION
Method:                    RA-LL impedance
Measurement range:          Adult: 7~120rpm;
Neonate/Pediatric: 7~150rpm
Apnea alarm:                YES, 10~40s
Resolution:                  1rpm
Accuracy:                   +2rpm
 
TEMPERATURE
Compatible probe:            YSI or CYF
Measurement range:          5~50ºC
Resolution:                  0.1ºC
Accuracy:                   +0.1ºC