MCCB Dam1-160 3p Approved Moulded Case Circuit Breaker with Kema Asta Certification

Price $14.50 Compare
Min Order 1000 Pieces
Shipping From Shanghai, China
Popularity 216 people viewed
Quantity
+-
 

Shanghai DaDa Electric Co., Ltd.

VIP   Audited Supplier 5 years
Profile Certified by SGS/BV
DAM1-160
Low Voltage Circuit Breakers
Manual Type
Normal Type Circuit Breaker
Arc Chamber
Fixed
MCCB
3
Circuit Breaker
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection
ISO9001-2000, CE, CB, CCC, Kema, Asta, Semko, RoHS
BMC Unflaming Material
BMC Unflaming Material
with Terminal Box
Left Side
1000V
400/415V
CDADA, OEM, ODM
Carton
16, 20, 25, 32, 40, 50, 70, 80, 100, 125, 160A
Shanghai, China
8536200000
Product Description

Introduction

The DAM1 series circuit breakers are intended for conducting current in normal mode and switching it off at short circuits, overload, inadmissible bucking as well as operational actuation and tripping of electric circuit parts. They are designed for use in electric units having the operative voltage limited to 400V per rated current from 12,5 to 1600A. 

They correspond to the requirements of EN 60947-1, EN 60947-2 


Thermal-Magnetic Circuit Breakers:

Thermal protection function:(For protection under over load conditions) 
Bimetal,  which provides thermal protection, consists of combination of two metals with different extension coefficients under heat. When bimetal is heated, it bends towards the metal with less extension. In this way, a notch that assists opening of the breaker mechanism is released to disable the breaker. Bending speed of bimetal is in direct proportion with size of the current passing through the breaker. Because, increase of current means increase of heat. In this way, over current protection function of the breaker is fulfilled by bimetal at load currents higher than the rated current 
Magnetic protection function (For protection under short circuit conditions) Another function of the breaker is to protect the connected circuit against short circuits. Short circuit may occur as a result of contact of phases with each other or contact of phase-ground. Since a very high current shall pass through the cables in case of short circuit, system energy should be broken in a shorter time due to thermal protection. Breaker should perform instant opening to protect load it is connected to. The part fulfilling this function is a mechanical opening mechanism that operates with magnetization caused by the magnetic area formed by the short circuit current
 
Thermal-Magnetic fixed type Circuit Breakers 
ModelDAM1-160
Breaking Capacity CodeBNS
Rated Current of Frame size- Inm                                                                   (A)160A
Rated Current-In(40,50 or 55ºC)                                                                     (A)10- 12,5-16-20 - 25 - 32 - 40  - 50 - 63 - 80 - 100 -125 - 160(150)A
Rated İnsulation Voltage -Ui(a.c.) 50-60Hz                                                   (V)750V
Rated operation Voltage  -Ue(a.c.) 50-60Hz                                                   (V)400/415V
Number of Pole3P / 4P
Rated ultimate short Circuit breaking Capacity  kA  Icu AC400V/50Hz O-CO         (KA)253550
Rated service short Circuit breaking Capacity  kA  Ics AC400V/50Hz O-CO-CO    (KA)12.526.2537.5
Rated short-circuit breaking capacity Icm(peak)/cos ф AC400V/50HZ O-CO        (KA)41/0.373.5/0.25110/0.25
Rated impulse withstand Voltage -Uimp                                                                           (V)8000
Dielectric Propery (V)3000
lonization distance                                                                                                             (mm)30/0
EnduranceTotal Cycles8000
Electrical Life1000
Mechanical Life7000
Over Current tripThermal and Magnetic release fix type
Category (EN 60947-2/IEC 60947-2)Main circuitA/0
Auxiliary circuitAC-15
Under Voltage Release 
Shunt Release
Auxiliary Contact
Alarm Contact
Auxiliary Contact and Alarm Contact
Handle Operation Mechanism
Electrical Operastion Mechanism 
DIN clips
Terminal cover  
Phase seperator  
Extention Handle  -
 W (mm)3P90
4P120
L (mm)3P120
4P120
H (mm)3P70
4P70
WeightFixed version 3P/4P1.2/1.6
Plug-in version 3P/4P1.4/1.8
Draw out version 3P/4P-
















Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA