Dam3-1000 800A 1000A 3p MCCB Moulded Case Circuit Breaker Electronic Tama Adjustable CB Approved Factory Price

Price $153.00 Compare
Min Order 1000 Pieces
Shipping From Shanghai, China
Popularity 221 people viewed
Quantity
+-
 

Shanghai DaDa Electric Co., Ltd.

VIP   Audited Supplier 5 years
Profile Certified by SGS/BV
DAM3-1000
Low Voltage Circuit Breakers
Manual Type
Normal Type Circuit Breaker
Arc Chamber
Fixed
MCCB
3
Circuit Breaker
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection
ISO9001-2000, CE, CB, CCC, RoHS
BMC Unflaming Material
Min:0.7-Max:1in
Min:5-Max:10in
CDADA, OEM, ODM
Carton
800, 1000A
Shanghai, China
8536200000
Product Description

Overview


The rated current of DAM3-1000 molded case circuit breaker can up to 1000A, it's generally used in the power distribution circuit to distribute power and protect circuit and power equipment from overloaded, short circuit, under voltage failure damage, in which alternating current 50-60Hz, rated direct-current 1000A.

Compared to the DAM1 series, the DAM3 series are designed for smaller volume, higher breaking capacity, offering better energy savings.

Electrical parameters of DAM3-1000 molded case circuit breaker
Rated current of frame size Inm [A] 1000
Rated current[A]630 800 1000
Number of poles3 / 4
Rated operating voltage(AC)50-60HZ [V]400/690
DC[V]250/1000
Rated impulse withstand voltage Uimp[KV]8
Rated insulation voltage Ui [V]750
Test voltage at industrial frequency for 1 min [V]3000
Rated ultimate short-circuit breaking capacity Icu [KA]NSH
(AC)50-60HZ 220/230V [KA]5580105
(AC)50-60HZ 400/415V [KA]365570
(AC)50-60HZ 690V [KA]152025
(DC)250V-2 Poles in series355065
(DC)500V-2 Poles in series182230
(DC)750V-4 Poles in series304255
(DC)1000V-4 Poles in series253545
Rated service short-circuit breaking capacity, Ics [KA]   
(AC)50-60HZ 220/230V [%Icu]60%60%60%
(AC)50-60HZ 400/415V [%Icu]60%60%60%
(AC)50-60HZ 690V [%Icu]60%60%60%
Category of utilisation(EN 60947-2)A
Isolation conditionBitmap
Reference standardIEC/EN 60947-2/GB 14048.2
InterchangeabilityBitmap
VersionsFixedBitmap
Plug-inBitmap
Draw-outBitmap

Physical parameters of DAM3-1000 molded case circuit breaker
EnduranceTotal cycles5000
Electrical endurance1000
Mechanical endurance4000



Basic dimensjons-fixed version
3/4 Poies W[mm]210/280
3/4 Poies H[mm]108.5
H1[mm]167
3/4 Poies L[mm]268

Introduction
The DAM3-1000 molded case circuit breaker automatically cuts off the current when the current exceeds the release setting. The molded case refers to the plastic insulator used as the frame of the device to insulate the conductor and the metal grounding component.














Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA