Factory Magnetic Moulded Case Circuit Breaker Fixed Type Thermal Overload Cm1

Price Negotiable Compare
Min Order 1000 Pieces
Shipping From Shanghai, China
Popularity 422 people viewed
Quantity
+-
 

Shanghai DaDa Electric Co., Ltd.

VIP   Audited Supplier 5 years
Profile Certified by SGS/BV
CM1-125
Low Voltage Circuit Breakers
Manual Type
Normal Type Circuit Breaker
Arc Chamber
Fixed
MCCB
3
Circuit Breaker
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection
CDADA, OEM, ODM
Carton
12.5, 16, 20, 25, 32, 40, 50, 70, 80, 100A
Shanghai, China
85362000
Product Description
 


The DAM2 series Moulded Case Circuit Breaker represents the pinnacle of advanced circuit breaker technology, designed meticulously by Shanghai DaDa Electric Co., Ltd. Boasting a compact size, exceptional breaking capacity, minimal arc-over distance, and robust shakeproof features, these circuit breakers are the perfect solution for both land-based and marine applications.

Application

The DAM2 (CM1) series, with a rated insulation voltage of 800V, is engineered for AC 50Hz/60Hz distribution networks, supporting a working voltage of 690V and a current of up to 1250A. These breakers safeguard against overloads, short circuits, under-voltage, and other faults, ensuring the protection of circuits and power equipment. Suitable for both infrequent circuit conversions and motor starts, the DAM2 series can be installed vertically or horizontally and serves as an isolation unit. It adheres to the IEC60947-2 standard for low-voltage switchgear and control equipment.

Normal operating conditions

1. Ambient air temperature: -5ºC to +40ºC, with a maximum 24-hour average below +35ºC.
2. Altitude: Installation sites must not exceed an altitude of 2000m.
3. Atmospheric conditions: Maximum relative humidity of 50% at +40ºC, higher humidity permissible at lower temperatures. Average monthly relative humidity can reach 90% at +25ºC, accounting for temperature-induced condensation.
4. Pollution Degree: 3.
 

Selection of instructions

Circuit breakers are classified into four types based on their poles:
Type A: N-pole without over-current release components, always connected, and does not engage with the other three poles to switch on or off.
Type B: N-pole without over-current release components, engages with the other three poles (N-pole turns on before and off after the others).
Type C: N-pole equipped with over-current release components, engages with the other three poles (N-pole turns on before and off after the others).

Classification according to rated current of over-current release:
DAM2-63 MCCB offers nine options: 6, 10, 16, 20, 25, 32, 40, 50, and 63 A. MCCB has nine: 6,10,16,20,25,32,40,50,63 A;
DAM2-100 MCCB offers nine options: 16, 20, 25, 32, 40, 50, 63, 80, and 100 A. MCCB has nine: 16,20,25,32,40,50,63,80,100 A;
DAM2-250 MCCB offers seven options: 100, 125, 140, 160, 180, 200, 225, and 250 A. MCCB has seven: 100,125,140,160,180,200,225 ,250A;
DAM2-400 MCCB offers five options: 225, 250, 315, 350, and 400 A. MCCB has five: 225,250,315,350,400 A;
DAM2-630 MCCB offers three options: 400, 500, and 630 A. MCCB has three: 400,500,630 A;
DAM2-800 MCCB offers three options: 630, 700, and 800 A. MCCB has three: 630,700,800A;
DAM2-1250 MCCB offers three options: 800, 1000, and 1250 A.
Remark: The 6A variant features solely an electromagnetic (instantaneous) type, hence, it is not recommended.
According to the wiring method: front board wiring, back board wiring, and insertion type.
Over-current release patterns: thermodynamic-electromagnetic (dual) type and electromagnetic (instantaneous) type.
Outfit options: available with or without outfit.
Outfit includes both internal and external accessories. Internal accessories comprise shunt release, under-voltage release, auxiliary contact, and alarm contact. External accessories feature turning handle operation mechanisms and power-driven operation mechanisms, among others.
Breaking capacity classifications: L-standard breaking type, M-second high breaking type, H-high breaking type.

Technical parameters:

1. Instantaneous action characteristic setting: For distribution circuit breakers, it is 10In±20%; for DAM2-1250, it is 7In±20%. For motor protection circuit breakers, it is 12In±20%.
2. The rated values of the circuit breakers are detailed in Table 2.
3. At an ambient temperature of +40ºC, over-current release action characteristics for distribution and motor protection circuit breakers are detailed in Tables 3 and 4, respectively.

Rated values of the circuit breakers:

ModelPoleRated current (A)Rated
operating
voltage (V)
Rated
insulation
voltage (V)
Rated ultimate short - circuit breaking capacity (Icu)Flashover
distance(mm)
Test voltage (V)Icu (kA)Ics (kA)
DAM2L-63310,16,20,25,
32,40,50,63
400500400×1.1025180
DAM2M-633,45035
DAM2L-1003,416,20,25,32,40,
50,63,80,100
4008003022≤50
DAM2M-1002,3,45035
DAM2H-10038550
DAM2L-1003,4690105
DAM2M-1002,3,42010
DAM2L-2253,4100,125,140,
160,180,200,225
4008003525
TXCM1-2252,3,45035
DAM2H-22538550
DAM2L-2253,4690105
DAM2M-2252,3,42010
DAM2L-4003225,250,315,
350,400
4008005035≤100
DAM2M-4003,46542
DAM2H-400310065
DAM2L-4003690158
DAM2M-4003,42010
DAM2L-6303400,500,6304008005035
DAM2M-6303,46542
DAM2H-630310065
DAM2L-63036910158
DAM2M-6303,42010
DAM2M-8003630,700,8004008007550
DAM2H-800310065
DAM2M-800346903015
DAM2-12503800,1000,12504008008542
DAM2-125036902512.5
 

Note: For 2-pole and 4-pole circuit breakers, categorized as L, M, H, the breaking index aligns with M-type.

Characteristics of inverse time breaking action for power distribution circuit breakers' over-current release when all poles are energized simultaneously.

No.Test currentI/InSet timeInitial state
1Conventional non-tripping current1.052h(In>63A),1h(In≤63A)Cold
2Conventional non-tripping current1.302h(In>63A),1h(In≤63A)Immediately after Test 1
 

Instantaneous action characteristic setting for distribution circuit breakers is 10In±20%, and for motor protection circuit breakers, it is 12In±20%.

Characteristics of inverse time breaking action for motor protection circuit breakers' over-current release when all poles are powered simultaneously.

No.I/InSet timeInitial stateRemark
11.0>2hCold 
21.2≤2hImmediately after Test 1 
31.5≤4minCold10≤n≤225
≤8min225 < in ≤ 630
47.24s≤T≤10sCold10≤In≤225
6s≤T≤20s225 < in ≤ 630
 

Accessories:

1. Internal accessories of circuit breakers:

1.1 Shunt release:
Rated control supply voltage for shunt release: AC50Hz, 230V, 400V; DC110V, 220V, 24V. Ensures reliable circuit breaker operation within 70%~110% of rated voltage.

For a DC24V rated control supply voltage, the maximum length of copper wire must adhere to specified requirements:

Rated control
supply voltage Uc(DC24V)/Conductor area
1.5mm²2.5mm²
100%Uc
85%Uc
150m
100m
250m
160m
 

If these specifications are not met, consider designing the shunt release control circuit according to the provided diagram.

1.2 Under-voltage release:

When power supply voltage drops to 70%~35% of under-voltage release rated voltage, the circuit breaker reliably disconnects.
If the voltage falls below 35% of the rated voltage, the under-voltage release prevents the circuit breaker from closing.
When the supply voltage exceeds 85% of the under-voltage release rated voltage, it ensures the circuit breaker remains closed.
Under-voltage releases are rated at AC50Hz, 230V and 400V.
400V.
Special Note: Circuit breakers with under-voltage release can only operate normally when supplied with the rated voltage.
normally.

1.3 Pre-paid meter dedicated release:

The rated operating voltage (Ue) of the pre-paid meter dedicated release is AC230/50Hz, ensuring reliable performance within a broad range of (65% ~ 110%) Ue. Upon the Ctrl being cut off, the circuit breaker will gracefully delay by 0.5s ~ 2s before opening.

Wiring Diagram: Pre-paid Meter Dedicated Release

1.4 Rated Values of Auxiliary Contacts and Alarm Contacts: Refer to Table 5

ClassificationConventional thermal current (Ith)Rated current when

 

AC 400V Ie(AC-15)

Rated current when

 

DC 220V Ie(DC-13)

Auxiliary contact30.40.15
Alarm contact30.30.15
 

a. Auxiliary Contact: Detailed Specifications

b. Alarm Contact: Detailed Specifications
Alarm contacts remain inactive during normal circuit breaker operations, switching between normal open and closed states only in cases of free or fault tripping.

2. External Accessories for Circuit Breakers

2.1 Motor Operating Mechanism: Rated values and corresponding codes are outlined in Table 6.

Category/ModelDAM2-63. 125. 250DAM2-400. 630. 800. 1250
Structure typeElectromagnetMotor
AC voltage codeAC50Hz,230V,400AC50Hz,230V,400
DC voltage codeDC110V,220VDC110V,220V
 

NOTE: Post-tripping of a circuit breaker with an electric operating mechanism requires the mechanism to reset the breaker before it can close again.

Principle Diagram: Opening and closing operation of DAM2-63,100,225 Electric Operating Mechanism (AC)

Principle Diagram: Opening and closing operation of DAM2-400,630,800,1250 Electric Operating Mechanism (AC)

2.2 Installation Dimensions: Manual Operating Mechanism as shown in Table 10
Handle Mounting Hole Diagram: DAM2-63~800

Total Height: Electric/Manual Operating Mechanism of Circuit Breaker (mm) as shown in Table 12

ModelTotal height of electric
operating mechanism H
Installation dimensions

 

of manual operating mechanism H

DAM2L-6315549
DAM2M/H-6316449
DAM2L-10015251
DAM2M/H-10017051
DAM2L-22518254
DAM2M/H-22519954
DAM2L/M/H-40025588
DAM2M/H-63026289
DAM2M/H-80026196
DAM2H-1250290103
 

Fast Selection Guide: DAM2 Series Molded Case Circuit Breaker

Corresponding
letters
Function nameFunction corresponding to the model
aModel featuresDAM2 Molded Case

 

Circuit Breaker

bFrame rated current code63A,100A,225A,

 

400A,630A,800A,

1250A

cBreaking capacity characteristic
code
L-standard breaking type;

 

M-second high breaking type;

H-high breaking type

dOperation mode codeNo code for handle operation;

 

P for electric operation;

Z for turning handle operation

ePole2-two poles;

 

3-three poles;

4-four poles

fRelease name2 Electromagnetic release;

 

3 Double release

gAccessory00 Without accessory
08 Alarm contact
10 Shunt release
20 Auxiliary contact
30 Undervoltage release
40 Shunt release, Auxiliary contact
50 Shunt release, Undervoltage release
60 Two sets of auxiliary contacts
70 Auxiliary contact, Undervoltage release
18 Shunt release, Alarm contact
28 Auxiliary contact, Alarm contact
38 Undervoltage release, Alarm contact
48 Shunt release, Auxiliary contact, Alarm contact
58 Shunt release, Undervoltage release, Alarm contact
68 Two sets of auxiliary contacts, Alarm contact
78 Auxiliary contact, Undervoltage release, Alarm contact
10Y Pre-paid meter dedicated release
40Y Pre-paid meter dedicated release, Auxiliary contact
50Y Pre-paid meter dedicated release, Auxiliary contact, Undervoltage release
18Y Pre-paid meter dedicated release, Alarm contact
48Y Pre-paid meter dedicated release, Auxiliary contact, Alarm contact
58Y Pre-paid meter dedicated release, Undervoltage release, Alarm contact
hApplicationNo code for distribution;

 

2 for motor protection

iConventional productsNo code;

 

T for transparent cover products

jAmperage10,16,20,25,32,63,80,100,125,160,180,200
,225,250,315,350,400,500,630,700,800,1000
,1250
 

Example: DAM2L-100 / 33102 63A defines a DAM2-type molded case circuit breaker with a frame rated at 100A, standard breaking capacity, handle operation, 3 poles, double release, shunt release, motor protection, and a rated current of 63A.
Selection, installation, and use must adhere to the product manual or pertinent national standards.
Note: For N-pole type 4P circuit breakers, A-type and B-type exist. Absence of specification defaults to B-type.

Working Principle: Core Functionality
The primary contact of the molded case circuit breaker can be managed manually or electrically. Once closed, the free release mechanism secures the main contact in the closed position.
The overcurrent trip coil and thermal trip element are serially connected to the main circuit.
The undervoltage
release
coil is parallelly connected to the power supply.