YLC-600
98% Kill Total Coliforms
Stainless Steel Ss304, Ss316
PP (Propene Polymer)
9000-12000 Hours
Flange or Thread
0.3--1000 Ton/Hour
One Set
(0.6 MPa)6kg/Cm2
Running Water
Beasun
YLD
Plywood Case Into Container
CE, SGS, ISO
Jiangyin, Jiangsu
8421219990
Product Description
Product Description
Ultraviolet sterilizers use ultraviolet (UV) light to disinfect system water, destroying any waterborne pathogens. Unlike chlorine or bromine, UV sterilization leaves no toxic residuals in the water which may be harmful to the animals.
The sterilizer assembly consists of ultraviolet sterilizing lamp, quartz sleeve, and housing.
Product features
UV light will kill any DNA based micro organism when give enough UV dosage.
UV break micro organism's DNA in a cumulative basis.
Continuous disinfection in cooling water. If micro organism is not effectively deactivated on the first disinfection cycle and in the next cycle it get UV treated.
For 90% kill algae 30000 μWs/cm2 is required for one cycle .
UV spectrum between 185-400nm has a strong germicidal effect, with peak effectiveness at 265nm.
UV works instantaneously against all water-borne microorganisms, including bacteria, viruses, molds, spores and protozoa - including those resistant to chlorine.
UV systems are also very easy to use and can be effectively monitored and integrated with online process control systems.
UV disinfection systems are very compact, modular and easy to
install into existing water treatment systems.
UV does not cause the formation of chemical disinfection by-
products, many of which can have undesired effects of their own.
UV sterilizer is eco-friendly and cost effective.

How Does UV Sterilisation Work?
The optimum solution to remove ecoli , cryptosporidium , coliforms and all bacteria from your water is to install a Nature's Water Ltd. Ultraviolet Water Sterilizer. This will then allow you to have 100% bacteria free water in your premises - NO MORE VIRUSES OR BACTERIA! We can call and install the system for you. Click here for more information. If required we can call to you and assess your premises for location and workings of the system first-hand, Click here for a free call-out. If you would like a full water analysis from the laboratory to ensure that Coliform Bacteria is the only issue click here to arrange a water test.

What Contaminants Do UV Sterilizers Remove?
There are no micro-organisms known to be resistant to UV, unlike chlorination. UV is known to be highly effective against bacteria, viruses, algae, molds and yeasts, and disease causing oocysts like cryptosporidium and giardia. In practice, bacteria and viruses are the cause of most major waterborne pathogenic diseases. Of these enteric viruses, hepatitis virus and Legionella pneumophila have been shown to survive for considerable periods in the presence of chlorine, but are readily eliminated by UV treatment. For most microorganisms, the removal efficiency of UV for microbiological contaminants such as bacteria and virus generally exceeds 99.99%.
CONVENTIONAL METHODS OF WATER TREATING | |||
CHLORINE | OZONE | ULTRA VIOLET | |
Capital cost | Lowest | High | Low |
Ease of installation | Good | Poor | Excellent |
Ease of Maintenance | Good | Poor | Excellent |
Cost of Maintenance | Medium | High | Lowest |
Operating Cost | Low | High | Low |
Frequency Of Maintenance | Frequent | Continuous | V. Infrequent |
Control System | Poor | Good | Excellent |
Virucidal Effect | Good | Poor | Good |
Toxic Chemical | Yes | Yes | No |
Residual Effect Problem with | Yes | Yes | No |
Hazards | High | Yes | Low to none |
Contact Time | 30 - 60 minutes | High | 1 - 5seconds |
Disinfection Performance | Leaves some pathogens | Kills all microbes | Kills all microbes |
Effect on Water | Organochlorine compounds, Taste & pH changes | Unknown | None |
The Ultra violet dose required for destruction is about the same for each virus, while higher dose of chlorine & ozone needed. |
Technical parameters:
model | capacity | Power | inlet-outlet | reactor | panel | Anchor | G weight |
m³/hour | watt | mm | L×W×H | cm | screw | Kg | |
YLCn-005 | 0.3 | 16 | 1/2″ | 30×6×11 | without | without | 5 |
YLCn-008 | 1 | 25 | 1/2″ | 47×6.3×11 | without | without | 10 |
YLCn-050 | 2 | 40 | 1″ | 100×9×20 | Φ8.9×25 (d×L) | 69×4×Φ1 | 25 |
YLCn-150 | 6 | 80 | 1+1/4″ | 100×11×23 | 69×4×Φ1 | 30 | |
YLCn-200 | 8 | 120 | 1+1/2″ | 100×15.9×30 | Φ8.9×45 (d×L) | 69×7×Φ1 | 35 |
YLCn-300 | 12 | 160 | 2″ | 100×15.9×32 | 69×7×Φ1 | 40 | |
YLC-050 | 2 | 40 | DN25/1″ | 100×8.9×30 | 25×30×12 (W×H×D) | 60×4×Φ1 | 45 |
YLC-150 | 6 | 80 | DN32/11/4″ | 100×10.8×30 | 60×4×Φ1 | 50 | |
YLC-200 | 8 | 120 | DN40/11/2″ | 100×15.9×40 | 60×7×Φ1 | 60 | |
YLC-300 | 12 | 160 | DN50/2″ | 100×15.9×40 | 60×7×Φ1 | 70 | |
YLC-360 | 15 | 200 | DN65/21/2″ | 100×15.9×40 | 60×7×Φ1 | 120 | |
YLC-500 | 20 | 240 | DN65/21/2″ | 100×21.9×50 | 60×11×Φ1.2 | 130 | |
YLC-600 | 25 | 280 | DN80/3″ | 100×21.9×50 | 60×11×Φ1.2 | 140 | |
YLC-700 | 30 | 320 | DN100/4″ | 100×21.9×50 | 60×11×Φ1.2 | 150 | |
YLC-1000 | 40 | 360 | DN100/4″ | 100×21.9×50 | 60×11×Φ1.2 | 160 | |
YLC-1200 | 50 | 400 | DN125/5″ | 100×21.9×50 | 60×11×Φ1.2 | 180 | |
YLC-1500 | 60 | 420 | DN150/6″ | 170×27.3×57 | 120×16×Φ1.4 | 210 | |
YLC-2000 | 80 | 560 | DN150/6″ | 170×27.3×57 | 120×16×Φ1.4 | 220 | |
YLC-2500 | 100 | 700 | DN150/6″ | 170×27.3×57 | 60×128×30 (W×H×D) | 120×16×Φ1.4 | 275 |
YLC-3000 | 125 | 840 | DN150/6″ | 170×27.3×57 | 120×16×Φ1.4 | 300 | |
YLC-4000 | 150 | 1120 | DN200/8″ | 173×32.5×65 | 120×20×Φ1.6 | 325 | |
YLC-5000 | 200 | 1400 | DN200/8″ | 173×37.7×72 | 120×22×Φ1.6 | 350 | |
YLC-7000 | 300 | 2100 | DN250/10″ | 175×42.6×80 | 120×24×Φ2.0 | 400 | |
YLC-10K | 400 | 2520 | DN250/10″ | 176×52.9×95 | 60×150×40 (W×H×D) | 120×22×Φ2.2 | 475 |
YLC-15K | 600 | 3080 | DN300/12″ | 176×78×110 | 120×32×Φ2.4 | 600 | |
YLC-20K | 800 | 3920 | DN350/14″ | Designated | Designated | Designated | Designated |
YLC-25K | 1000 | 4760 | DN350/14″ | Designated | Designated | Designated | Designated |
Application
1. Food processing industry, including juices, milk, drinks, beer, practical oil and canned food.
2. Electronic industry.
3. Hospitals, various laboratory and high levels of pathogenic body water disinfection.
4. Households building, residential, office buildings, hotels, restaurants, water factories.
5. Purification and disinfection of shellfish, fish cleaning and disinfection
6. Military camp, field water supply system
7. Urban wastewater disinfection.
8. Swimming pool, other recreational water disinfection
9. Thermal power, nuclear power plant industrial, central air conditioning system cooling water.
10 . Biological, chemical and pharmaceutical, cosmetics for the production of cooling water.
11. Sea water, fresh water breeding, aquaculture water
12. Agricultural water disinfection