Veinasa-WSS01
Contact Customer Service
1 Year
Anemometer
Non-contact
Wire
Without Noctilucence
Waterproof
0~30m/S
≤0.3m/S
±(0.3+0.03V)M/S
0.1m/S
<1 Second
<1 Second
2m 3-Wire System (Analog Signal); 2m 4-Wire System
Veinasa
Covered with Carton Packing
5~24VDC, RS485 output, range: 0-30m/s
China
Product Description

Veinasa-WSS01 Promotion ABS Small Rs485 Output Tower Crane Digital Mechanical Anemometer Wind Speed Sensor
It's a wind speed sensor made of a polycarbonate composite; It has good anti-corrosion and anti-erosion characteristics. It can ensure the long-term use of the sensor without rust. At the same time, the internal smooth bearing system ensures the accuracy of information collection. The wind speed sensor integrates photoelectric conversion mechanism, industrial microcomputer processor, standard current generator, current driver and so on.
Wind speed sensor Features:
(1) Small size, light weight, high measurement accuracy.
(2) Fast response speed and good interchangeability.
(3) Truly achieve low cost, low price and high performance.
(4) Flange installation mode, can achieve the bottom line, side line, simple and convenient.
(5) The power supply has a wide range of adaptability, good linearity of data information, and long signal transmission distance.
(6) 2-in-1, reliable data.
Wind speed sensor Features:
(1) Small size, light weight, high measurement accuracy.
(2) Fast response speed and good interchangeability.
(3) Truly achieve low cost, low price and high performance.
(4) Flange installation mode, can achieve the bottom line, side line, simple and convenient.
(5) The power supply has a wide range of adaptability, good linearity of data information, and long signal transmission distance.
(6) 2-in-1, reliable data.
Measuring Range | 0~30m/s; 0~50m/s; 0~60m/s; (Other ranges can also be customized) |
Start Wind Speed | ≤0.3m/s |
Accuracy | ±(0.3+0.03V)m/s |
Resolution | 0.1m/s |
Output signal | A: Voltage signal (Choose one of 0~2V, 0~5V, 0~10V) |
B: 4~20mA (Current loop) | |
C: Pulse signal (pulse high potential 3.3V) | |
D: RS485 (Standard Modbus-RTU protocol, device default address: 01) | |
E: SDI-12 (American Hydrological Organization Serial Data Communication Interface Protocol) | |
Supply voltage | 5~24V DC (When the output signal is 0~2V, RS485, Pulse signal, SDI-12) |
12~24V DC (When the output signal is 0~5V, 0~10V, 4~20mA) | |
Stability Time | <1 second |
Response Time | <1 second |
Working Environment | Temperature: -30~70°C; Humidity: <100%RH |
Storage Environment | Temperature: -30~70°C; Humidity: <100%RH |
Cable Specification | 2m 3-wire system (analog signal); 2m 4-wire system (RS485) (optional cable length) |