MIS Acetabular Grater Head (Minimally Invasive Surgery)
1. General Description
The MIS Acetabular Grater Head is a specially designed surgical tool for minimally invasive hip surgeries (MIS), offering enhanced accessibility and efficiency compared to standard acetabular reamers. Its unique design, which features two missing quadrants, provides reduced bulk and improved maneuverability in smaller surgical incisions, making it ideal for MIS procedures. Manufactured from medical-grade stainless steel (420B), it combines high strength, biocompatibility, and durability, with a surface hardness of approximately 45 HRC. Compatible with Crossbar, Hexagonal, and Bridgeback interfaces, this grater head integrates seamlessly with major global surgical systems, including Stryker, Synthes, and Zimmer.
2. Features
- Optimized for MIS: The two missing quadrants reduce bulk, enhancing maneuverability in minimally invasive procedures.
- Material: Constructed from 420B stainless steel, offering superior durability, corrosion resistance, and biocompatibility.
- Interface Options: Available in Crossbar, Hexagonal, and Bridgeback designs, ensuring compatibility with leading global brands.
- Handle Interface: Standard connection is the Hudson interface, with additional options for Stryker, Synthes, and Zimmer handles.
- Precision Sizing: Available in 1mm increments (36mm to 66mm) for accurate acetabular preparation and implant fitting.
- Polished Perforated Design: Reduces weight, improves debris removal, and ensures smooth performance during reaming.
- Sterility: Delivered non-sterile, requiring sterilization before use.
3. Intended Use
The MIS acetabular grater head is designed for orthopedic surgeries, particularly for minimally invasive approaches to primary and revision total hip arthroplasty, where precise acetabular preparation is required.
4. Indications
- Primary Total Hip Arthroplasty: For patients with advanced hip joint degeneration caused by osteoarthritis or rheumatoid arthritis.
- Hip Fractures and Trauma: Cases requiring acetabular preparation and reconstruction.
- Revision Hip Surgeries: To reshape or replace the acetabular cavity during implant revisions.
- Developmental Dysplasia of the Hip (DDH): Corrective acetabular preparation for joint reconstruction.
5. Contraindications
- Active Infection: Localized or systemic infections at or near the surgical site.
- Severe Bone Loss: Patients with inadequate bone quality or structure for implant support.
- Material Sensitivity: Allergic reactions to stainless steel 420B or its components.
- Non-Surgical Alternatives: When non-invasive treatment options are more suitable for the patient's condition.
6. Product Parameters Table
Product Name | MIS Acetabular Grater Head |
---|---|
Material | Medical-Grade Stainless Steel 420B |
Hardness | ~45 HRC |
Size Range | 36mm - 66mm |
Increment | 1mm |
Interface Options | Crossbar, Hexagonal, Bridgeback |
Compatible Brands | Stryker, Synthes, Zimmer |
Handle Interface | Hudson (other options available) |
Surface Design | Polished, perforated for efficiency |
Sterility | Supplied non-sterile |
7. Advantages for MIS Procedures
- Enhanced Access: The reduced bulk design allows easy access and precise control in smaller surgical incisions, making it ideal for minimally invasive techniques.
- Improved Efficiency: The lightweight and perforated design reduces surgical fatigue and improves debris clearance during reaming.
- Compatibility: Seamlessly integrates with major global surgical systems, ensuring ease of use and reliable performance in various clinical setups.
- Precision: Available in 1mm increments to ensure an exact fit for prosthetic acetabular cups, reducing implant failure risks.
This MIS acetabular grater head represents the next generation of precision surgical tools for hip arthroplasty, combining innovative design with compatibility and reliability. It is an essential instrument for surgeons seeking high performance in minimally invasive hip surgeries while maintaining accuracy and safety.