3, 4, 5, 6, 7, 8 holes
Non-Customized
ISO, CE
New
Correct Deformities, Fracture Fixation
Clavicle
Internal Fixation
Available with 3, 4, 5, 6, 7, 8 Holes
67 mm, 81 mm, 95 mm, 109 mm, 122 mm, 135 mm
Clavicle
Medical-Grade Titanium (Ta3g) for Biocompatibility
Compatible with Ao/Asif System
for Clavicle Shaft Surgery
Pre-Contoured for Anterior Clavicle Shaft
Ha 2.7, Ha 3.5 Locking Screws
High Resistance to Bending and Torsion
1203
Polished Surface for Reduced Tissue Irritation
for Fixation of Fractures in Clavicle Shaft
Non-Sterile, Requires Sterilization Before Use
Single-Use Implant
Non-Contourable Design for Optimal Stability
BEST MEDICAL
1 PC/Package
Medical grade Titanium
China
9021100000
Product Description
Features:
- Anatomically contoured design for optimal fit on clavicle bones.
- Includes multiple holes (3 to 8) for flexible screw placement.
- Compatible with locking screws of sizes 2.7/3.5mm, HA3.5, and HB4.0.
- Made from high-strength, biocompatible material suitable for fracture fixation.
- Available in left and right versions for proper anatomical fit.
Intended Use:
This clavicle anterior upper locking plate II is intended for surgical fixation of clavicle fractures, specifically for the anterior upper region of the clavicle. It is designed to provide rigid stabilization to allow proper bone healing.
Indications:
- Displaced clavicle fractures, especially those in the midshaft and lateral third.
- Comminuted fractures of the clavicle that require rigid fixation.
- Non-union fractures of the clavicle.
- Complex fractures in the anterior upper clavicle requiring anatomical contouring.
Contraindications:
- Active infection at the surgical site.
- Insufficient bone quality to support screw fixation.
- Patients with known allergies to the implant materials.
- Fractures where non-operative treatment is recommended.
Product Parameters:
Parameter | Details |
Product Name | Clavicle Anterior Upper Locking Plate II (L/R) |
Material | High-strength, biocompatible titanium alloy or stainless steel |
Surface Treatment | Polished or anodized for enhanced corrosion resistance |
Plate Type | Anatomically contoured locking plate for clavicle fractures |
Available Versions | Left (L) and Right (R) |
Holes Configuration | 3, 4, 5, 6, 7, 8 holes |
Length (mm) | 67 mm, 81 mm, 95 mm, 109 mm, 122 mm, 135 mm |
Screw Compatibility | HA 3.5mm, HB 4.0mm, Locking screws 2.7/3.5 mm |
Indications | Clavicle fractures (midshaft, lateral third), non-union fractures, osteotomies |
Contraindications | Active infection, poor bone quality, known allergies to implant materials |
Sterilization Method | Provided in unsterile packaging, requires sterilization prior to surgery |
Screw Angle | Variable angle locking capability for enhanced fixation |
Fixation Type | Rigid fixation with locking screw mechanism |
Intended Surgical Approach | Open reduction and internal fixation (ORIF) of clavicle fractures |
Packaging | Unsterile packaging, requires sterilization before use |
CE Certification | Certified for use in multiple international markets (CE compliant) |
Shelf Life | 5 years when stored in appropriate conditions |
Radiolucency | Compatible with imaging modalities like X-ray, CT |
Customization | Available in varying lengths and configurations for patient-specific needs |
Usage Environment | Operating room, under sterile conditions |