Ulna & Radius Anatomical Locking Bone Plate

Price $60.00 Compare
Min Order 1 Piece
Shipping From Jiangsu, China
Popularity 348 people viewed
Quantity
+-
 

Best Medical Device Co., Ltd.

VIP   Audited Supplier 1 year
Profile Certified by SGS/BV
6, 8, 10, 12, 14 holes
Non-Customized
ISO, CE
New
Correct Deformities, Fracture Fixation
Ulnar & Radius Shaft
Internal Fixation
2302
6, 8, 10, 12, 14 Holes
98 mm, 126 mm, 152 mm, 180 mm, 206 mm
Ha 3.5mm, Hb 4.0mm, Locking Screws 3.5mm
Ulnar & Radius Shaft Fractures
Medical-Grade Titanium (Ta3g) for Biocompatibility
Compatible with Ao/Asif System
for Ulnar & Radius Shaft Fractures
for Ulnar & Radius Shaft Stabilization
High Resistance to Bending and Torsion
Polished Surface for Reduced Tissue Irritation
Ulnar & Radius Shaft Requiring Stabilization
Non-Sterile, Requires Sterilization Before Use
Single-Use Implant
Active Infection at The Surgical Site
BEST MEDICAL
1 PC/Package
Medical grade Titanium
China
9021100000
Product Description
Product Description

Material: Titanium, not stainless steel

 
Features:
  1. High-Strength Titanium Construction:
    The plate is made from biocompatible titanium, which offers superior strength and corrosion resistance. Titanium ensures durability and lightweight characteristics, making it suitable for long-term implantation in orthopedic surgeries.
  2. Polished Surface to Minimize Tissue Irritation:
    The surface of the plate is polished to reduce friction with surrounding tissues. This minimizes irritation, promotes faster healing, and increases patient comfort post-surgery.
  3. Anatomically Contoured Design for Optimal Fit:
    The plate is anatomically designed to conform to the natural curvature of the ulna and radius bones, providing a precise fit. This design ensures better alignment and stability, reducing the need for intraoperative adjustments.
  4. Locking Screw Mechanism for Secure Fixation:
    The locking mechanism allows screws to securely lock into the plate, providing rigid fixation. This ensures that the bone fragments remain properly aligned during the healing process, reducing the likelihood of complications or the need for additional surgeries.
  5. Multiple Hole Configurations and Lengths for Versatility:
    The plate is available in multiple hole configurations, ranging from 6 to 14 holes, and varying lengths from 98 mm to 206 mm. This versatility allows the plate to be tailored to a wide variety of fracture types and patient anatomies.
  6. Compatibility with Different Screw Types:
    The plate is compatible with HA 3.5 mm and HB 4.0 mm locking screws, providing surgeons with flexibility in fixation techniques, ensuring stable fixation across a range of fractures.
  7. Non-Sterile Packaging:
    Supplied in non-sterile packaging, the plate requires sterilization prior to use. This ensures adherence to surgical and hospital sterilization standards, preventing infection during surgery.
  8. Radiolucency for Imaging Compatibility:
    Titanium's radiolucent properties ensure that it does not interfere with imaging modalities such as X-rays and CT scans. This feature allows for clear post-operative monitoring and accurate diagnosis without obstruction.
 
Indications

Intended Use:

The Ulna & Radius Anatomical Locking Plate is intended for the fixation and stabilization of fractures in the ulna and radius, particularly for anatomical fractures where a precise fit is required. The plate is designed to provide secure fixation for both simple and complex fractures, facilitating early mobilization and bone healing.
 
Indications:
  • Ulna fractures
  • Radius fractures
  • Anatomical fractures of the ulna and radius
  • Osteosynthesis of the ulna and radius
  • Open and closed fractures in the forearm
  • Post-traumatic deformities
  • Malunion and non-union fractures in the ulna and radius
 
Contraindications

Contraindications:

  • Active infection at the site of implantation
  • Severe osteoporosis or compromised bone quality
  • Allergies to titanium or any other implant material
  • Extensive soft tissue damage that may hinder stable fixation
 
Product Parameters

Product Parameters Table

ParameterDetails
Product NameUlna & Radius Anatomical Locking Bone Plate
MaterialHigh-strength, biocompatible titanium
Surface TreatmentPolished for reduced tissue irritation and enhanced corrosion resistance
Plate TypeAnatomically contoured locking plate for ulna and radius fractures
Available VersionsMultiple versions based on hole configuration
Holes Configuration6, 8, 10, 12, 14 holes
Length (mm)98 mm, 126 mm, 152 mm, 180 mm, 206 mm
Screw CompatibilityHA 3.5 mm, HB 4.0 mm, Locking screws 3.5 mm
IndicationsAnatomical fractures of the ulna and radius, Open and closed fractures
ContraindicationsActive infection, poor bone quality, allergies to titanium materials
Sterilization MethodSupplied in non-sterile packaging, requires sterilization before surgery
Fixation TypeRigid fixation using locking screws
Intended Surgical ApproachOpen reduction and internal fixation (ORIF) for ulna and radius fractures
PackagingUnsterile packaging, requires sterilization before use
CE CertificationCertified for use in multiple international markets (CE compliant)
Shelf Life5 years when stored in appropriate conditions
RadiolucencyRadiolucent for use with imaging modalities like X-ray and CT
CustomizationAvailable in different lengths and configurations for patient-specific needs
Usage EnvironmentOperating room, under sterile conditions
 
Inside Our Company

Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA