6, 8, 10, 12, 14 holes
Non-Customized
ISO, CE
New
Correct Deformities, Fracture Fixation
Ulnar & Radius Shaft
Internal Fixation
2302
6, 8, 10, 12, 14 Holes
98 mm, 126 mm, 152 mm, 180 mm, 206 mm
Ha 3.5mm, Hb 4.0mm, Locking Screws 3.5mm
Ulnar & Radius Shaft Fractures
Medical-Grade Titanium (Ta3g) for Biocompatibility
Compatible with Ao/Asif System
for Ulnar & Radius Shaft Fractures
for Ulnar & Radius Shaft Stabilization
High Resistance to Bending and Torsion
Polished Surface for Reduced Tissue Irritation
Ulnar & Radius Shaft Requiring Stabilization
Non-Sterile, Requires Sterilization Before Use
Single-Use Implant
Active Infection at The Surgical Site
BEST MEDICAL
1 PC/Package
Medical grade Titanium
China
9021100000
Product Description
Material: Titanium, not stainless steel
- High-Strength Titanium Construction:
The plate is made from biocompatible titanium, which offers superior strength and corrosion resistance. Titanium ensures durability and lightweight characteristics, making it suitable for long-term implantation in orthopedic surgeries. - Polished Surface to Minimize Tissue Irritation:
The surface of the plate is polished to reduce friction with surrounding tissues. This minimizes irritation, promotes faster healing, and increases patient comfort post-surgery. - Anatomically Contoured Design for Optimal Fit:
The plate is anatomically designed to conform to the natural curvature of the ulna and radius bones, providing a precise fit. This design ensures better alignment and stability, reducing the need for intraoperative adjustments. - Locking Screw Mechanism for Secure Fixation:
The locking mechanism allows screws to securely lock into the plate, providing rigid fixation. This ensures that the bone fragments remain properly aligned during the healing process, reducing the likelihood of complications or the need for additional surgeries. - Multiple Hole Configurations and Lengths for Versatility:
The plate is available in multiple hole configurations, ranging from 6 to 14 holes, and varying lengths from 98 mm to 206 mm. This versatility allows the plate to be tailored to a wide variety of fracture types and patient anatomies. - Compatibility with Different Screw Types:
The plate is compatible with HA 3.5 mm and HB 4.0 mm locking screws, providing surgeons with flexibility in fixation techniques, ensuring stable fixation across a range of fractures. - Non-Sterile Packaging:
Supplied in non-sterile packaging, the plate requires sterilization prior to use. This ensures adherence to surgical and hospital sterilization standards, preventing infection during surgery. - Radiolucency for Imaging Compatibility:
Titanium's radiolucent properties ensure that it does not interfere with imaging modalities such as X-rays and CT scans. This feature allows for clear post-operative monitoring and accurate diagnosis without obstruction.
Intended Use:
The Ulna & Radius Anatomical Locking Plate is intended for the fixation and stabilization of fractures in the ulna and radius, particularly for anatomical fractures where a precise fit is required. The plate is designed to provide secure fixation for both simple and complex fractures, facilitating early mobilization and bone healing.- Ulna fractures
- Radius fractures
- Anatomical fractures of the ulna and radius
- Osteosynthesis of the ulna and radius
- Open and closed fractures in the forearm
- Post-traumatic deformities
- Malunion and non-union fractures in the ulna and radius
Contraindications:
- Active infection at the site of implantation
- Severe osteoporosis or compromised bone quality
- Allergies to titanium or any other implant material
- Extensive soft tissue damage that may hinder stable fixation
Product Parameters Table
Parameter | Details |
Product Name | Ulna & Radius Anatomical Locking Bone Plate |
Material | High-strength, biocompatible titanium |
Surface Treatment | Polished for reduced tissue irritation and enhanced corrosion resistance |
Plate Type | Anatomically contoured locking plate for ulna and radius fractures |
Available Versions | Multiple versions based on hole configuration |
Holes Configuration | 6, 8, 10, 12, 14 holes |
Length (mm) | 98 mm, 126 mm, 152 mm, 180 mm, 206 mm |
Screw Compatibility | HA 3.5 mm, HB 4.0 mm, Locking screws 3.5 mm |
Indications | Anatomical fractures of the ulna and radius, Open and closed fractures |
Contraindications | Active infection, poor bone quality, allergies to titanium materials |
Sterilization Method | Supplied in non-sterile packaging, requires sterilization before surgery |
Fixation Type | Rigid fixation using locking screws |
Intended Surgical Approach | Open reduction and internal fixation (ORIF) for ulna and radius fractures |
Packaging | Unsterile packaging, requires sterilization before use |
CE Certification | Certified for use in multiple international markets (CE compliant) |
Shelf Life | 5 years when stored in appropriate conditions |
Radiolucency | Radiolucent for use with imaging modalities like X-ray and CT |
Customization | Available in different lengths and configurations for patient-specific needs |
Usage Environment | Operating room, under sterile conditions |