3, 4, 5, 7, 9, 11 holes
Non-Customized
ISO, CE
New
Correct Deformities, Fracture Fixation
Proximal Lateral Femur
Internal Fixation
3002
3, 4, 5, 7, 9, 11 Holes
140 mm, 163mm, 186mm, 232mm, 278mm, 324mm
Ha 4.5mm, Locking Screws 5.0mm
Comminuted Fractures of The Lateral Femur
Medical-Grade Titanium (Ta3g) for Biocompatibility
Compatible with Ao/Asif System
for Proximal Lateral Femoral Fractures
for Proximal Lateral Femoral Fractures
High Resistance to Bending and Torsion
Polished Surface for Reduced Tissue Irritation
Proximal Lateral Femur Fractures Requiring Surgery
Non-Sterile, Requires Sterilization Before Use
Single-Use Implant
Active Infection at The Surgical Site
BEST MEDICAL
1 PC/Package
Medical grade Titanium
China
9021100000
Product Description
Material: Medical-grade titanium
Features- Constructed from high-strength, biocompatible titanium for durability.
- Available in 3, 4, 5, 7, 9, and 11-hole configurations to accommodate various surgical needs.
- Designed for use with HA 4.5 mm and locking screws 5.0 mm.
- Anatomic contouring provides optimal fit for the lateral femur and reduces the need for bending during surgery.
- The polished surface reduces soft tissue irritation and improves corrosion resistance.
- Radiolucent properties allow for accurate imaging post-surgery.
Intended Use
The Proximal Lateral Femoral Locking Plate II is intended for the fixation of fractures, osteotomies, and nonunions of the proximal lateral femur, providing rigid stabilization during the healing process.Indications
- Proximal femoral fractures
- Comminuted fractures of the lateral femur
- Osteotomies of the femur
- Nonunions and malunions of the proximal femur
- Post-traumatic deformities requiring lateral femoral support
Contraindications
- Active infection or inflammation at the surgical site
- Severe osteoporosis or inadequate bone quality
- Known hypersensitivity to titanium or any other component of the plate
- Inadequate bone support for screw fixation
- Skeletally immature patients
Product Parameters Table
Parameter | Details |
Product Name | Proximal Lateral Femoral Locking Plate II (L/R) |
Material | Medical grade titanium |
Surface Treatment | Polished for corrosion resistance and minimal soft tissue irritation |
Plate Type | Locking plate for proximal lateral femoral fractures |
Available Versions | Left and right versions available |
Holes Configuration | 3, 4, 5, 7, 9, 11 holes |
Length (mm) | 140 mm, 163 mm, 186 mm, 232 mm, 278 mm, 324 mm |
Screw Compatibility | HA 4.5 mm, Locking screws 5.0 mm |
Indications | Proximal femoral fractures, osteotomies, nonunions |
Contraindications | Active infection, poor bone quality, titanium allergies |
Sterilization Method | Supplied unsterile, requires sterilization prior to use |
Fixation Type | Rigid fixation using locking screws |
Intended Surgical Approach | Open reduction and internal fixation (ORIF) for proximal femoral fractures |
Packaging | Non-sterile packaging, requires sterilization before use |
CE Certification | Certified for use in multiple international markets (CE compliant) |
Shelf Life | 5 years when stored under appropriate conditions |
Radiolucency | Radiolucent for use with imaging modalities like X-ray and CT |
Customization | Available in different lengths and configurations for patient-specific needs |
Usage Environment | Designed for sterile operating room conditions |