3, 4, 5 holes
Non-Customized
ISO, CE
New
Correct Deformities, Fracture Fixation
Proximal Lateral Femoral
Internal Fixation
3101
3, 4, 5 Holes
139mm, 157mm, 175mm
Ha 4.5mm, Hb 6.5mm Half-Thread Screws, 5.0/7.0mm
Comminuted Fractures of The Lateral Femur
Medical-Grade Titanium (Ta3g) for Biocompatibility
Compatible with Ao/Asif System
for Proximal Lateral Femoral Fractures
for Proximal Lateral Femoral Fractures
High Resistance to Bending and Torsion
Polished Surface for Reduced Tissue Irritation
Proximal Lateral Femur Fractures Requiring Surgery
Non-Sterile, Requires Sterilization Before Use
Single-Use Implant
Active Infection at The Surgical Site
BEST MEDICAL
1 PC/Package
Medical grade Titanium
China
9021100000
Product Description
Material: Titanium
Features- Manufactured from high-strength medical-grade titanium for durability and biocompatibility.
- Designed with 3, 4, and 5-hole configurations for flexible screw placement and optimized fracture fixation.
- Compatible with HA 4.5 mm and HB 6.5 mm half-thread, locking screws 5.0 mm and 7.0 mm.
- Anatomically contoured to fit the lateral aspect of the proximal femur, reducing the need for intraoperative bending.
- Polished surface for reduced soft tissue irritation and enhanced corrosion resistance.
- Radiolucent properties ensure accurate imaging post-surgery.
Intended Use
The Proximal Lateral Femoral Locking Plate (5.0/7.0) is intended for the fixation of fractures, osteotomies, and nonunions of the proximal lateral femur, providing rigid stabilization during the healing process.Indications
- Proximal femoral fractures
- Comminuted fractures of the lateral femur
- Osteotomies of the proximal femur
- Nonunions and malunions of the femur
- Post-traumatic deformities requiring lateral femoral support
Contraindications
- Active infection or inflammation at the surgical site
- Severe osteoporosis or inadequate bone quality
- Known allergies to titanium or implant materials
- Inadequate bone support for screw fixation
- Skeletally immature patients
Product Parameters Table
Parameter | Details |
Product Name | Proximal Lateral Femoral Locking Plate (5.0/7.0) |
Material | Medical-grade titanium |
Surface Treatment | Polished for corrosion resistance and minimal soft tissue irritation |
Plate Type | Locking plate for proximal lateral femoral fractures |
Available Versions | Left and right configurations available |
Holes Configuration | 3, 4, 5 holes |
Length (mm) | 139 mm, 157 mm, 175 mm |
Screw Compatibility | HA 4.5mm, HB 6.5mm half-thread screws, Locking screws 5.0/7.0mm |
Indications | Proximal femoral fractures, osteotomies, nonunions |
Contraindications | Active infection, poor bone quality, titanium allergies |
Sterilization Method | Supplied unsterile, requires sterilization prior to use |
Fixation Type | Rigid fixation using locking and half-thread cannulated screws |
Intended Surgical Approach | Open reduction and internal fixation (ORIF) for proximal femoral fractures |
Packaging | Non-sterile packaging, requires sterilization before use |
CE Certification | Certified for use in multiple international markets (CE compliant) |
Shelf Life | 5 years when stored under appropriate conditions |
Radiolucency | Radiolucent for use with imaging modalities like X-ray and CT |
Customization | Available in different lengths and configurations for patient-specific needs |
Usage Environment | Designed for sterile operating room conditions |