4, 5, 6, 7, 8, 9, 10 holes
Non-Customized
ISO, CE
New
Correct Deformities, Fracture Fixation
Proximal Lateral Femoral
Internal Fixation
3102
4, 5, 6, 7, 8, 9, 10 Holes
97mm, 117mm, 137mm, 157mm, 177mm, 197mm, 217mm
Ha 4.5mm, Hb 6.5mm Half-Thread Screws, 5.0/7.0mm
Proximal Femoral Intertrochanteric Fracture
Medical-Grade Titanium (Ta3g) for Biocompatibility
Compatible with Ao/Asif System
for Proximal Femoral Intertrochanteric Fracture
for Proximal Femoral Intertrochanteric Fracture
High Resistance to Bending and Torsion
Polished Surface for Reduced Tissue Irritation
Proximal Lateral Femur Fractures Requiring Surgery
Non-Sterile, Requires Sterilization Before Use
Single-Use Implant
Active Infection at The Surgical Site
BEST MEDICAL
1 PC/Package
Medical grade Titanium
China
9021100000
Product Description
Material: Titanium
Features- Manufactured from high-grade titanium for superior strength and biocompatibility.
- 135° design specifically for dynamic hip screw (DHS) fixation of proximal femoral fractures.
- Compatible with HA 4.5 mm screws, lag screw, and locking screws 5.0 mm.
- Multiple holes (from 4 to 10 holes) for variable screw placement and secure fixation.
- Polished surface for reduced soft tissue irritation and improved corrosion resistance.
- Pre-contoured to fit the femur, reducing the need for intraoperative adjustments.
Intended Use
The DHS Locking Plate (135°) is intended for fixation of fractures, nonunions, and malunions of the proximal femur. It is used in conjunction with dynamic hip screws for compressive fixation of the femoral head and neck.Indications
- Proximal femoral fractures
- Intertrochanteric fractures
- Subtrochanteric fractures
- Nonunion and malunion of femoral fractures
- Femoral neck and head fractures requiring dynamic compression
Contraindications
- Active infection or inflammation at the surgical site
- Severe osteoporosis or inadequate bone quality
- Known allergies to titanium or implant materials
- Inadequate bone support for screw fixation
- Skeletally immature patients
Product Parameters Table
Parameter | Details |
Product Name | DHS Locking Plate (135°) |
Material | Medical-grade titanium |
Surface Treatment | Polished for corrosion resistance and minimal soft tissue irritation |
Plate Type | Locking plate for dynamic hip screw (DHS) fixation at a 135° angle |
Available Versions | Left and right configurations available |
Holes Configuration | 4, 5, 6, 7, 8, 9, 10 holes |
Length (mm) | 97mm, 117mm, 137mm, 157mm, 177mm, 197mm, 217mm |
Screw Compatibility | HA 4.5 mm screws, Lag screw, Locking screws 5.0 mm |
Indications | Proximal femoral fractures, intertrochanteric fractures, subtrochanteric fractures |
Contraindications | Active infection, poor bone quality, titanium allergies |
Sterilization Method | Supplied unsterile, requires sterilization prior to use |
Fixation Type | Rigid fixation using lag and locking screws |
Intended Surgical Approach | Open reduction and internal fixation (ORIF) for proximal femoral fractures |
Packaging | Non-sterile packaging, requires sterilization before use |
CE Certification | Certified for use in multiple international markets (CE compliant) |
Shelf Life | 5 years when stored under appropriate conditions |
Radiolucency | Radiolucent for use with imaging modalities like X-ray and CT |
Customization | Available in different lengths and configurations for patient-specific needs |
Usage Environment | Designed for sterile operating room conditions |
Parameter | Details |
Product Name | Proximal Lateral Femoral Locking Plate (5.0/7.0) |
Material | Medical-grade titanium |
Surface Treatment | Polished for corrosion resistance and minimal soft tissue irritation |
Plate Type | Locking plate for proximal lateral femoral fractures |
Available Versions | Left and right configurations available |
Holes Configuration | 3, 4, 5 holes |
Length (mm) | 139 mm, 157 mm, 175 mm |
Screw Compatibility | HA 4.5mm, HB 6.5mm half-thread screws, Locking screws 5.0/7.0mm |
Indications | Proximal femoral fractures, osteotomies, nonunions |
Contraindications | Active infection, poor bone quality, titanium allergies |
Sterilization Method | Supplied unsterile, requires sterilization prior to use |
Fixation Type | Rigid fixation using locking and half-thread cannulated screws |
Intended Surgical Approach | Open reduction and internal fixation (ORIF) for proximal femoral fractures |
Packaging | Non-sterile packaging, requires sterilization before use |
CE Certification | Certified for use in multiple international markets (CE compliant) |
Shelf Life | 5 years when stored under appropriate conditions |
Radiolucency | Radiolucent for use with imaging modalities like X-ray and CT |
Customization | Available in different lengths and configurations for patient-specific needs |
Usage Environment | Designed for sterile operating room conditions |