3kVA/50kV AC Hipot Test Set Withstand Voltage Tester (dry type transformer) GDYD-53D

Price $2000.00 Compare
Min Order 1 Set
Shipping From Hubei, China
Popularity 441 people viewed
Quantity
+-
 

HV Hipot Electric Co., Ltd.

VIP   Audited Supplier 14 years
Profile Certified by SGS/BV
GDYD-53D
Power, Electronic, Instrument
Single
Core-type Transformer
Dry-type Transformer
Separated Winding Transformer
ISO9001-2000, ISO9001
Test and Measurement Instruments
Power Frequency
OD
HV HIPOT
0-50kv
0-3kVA
0-60mA
AC220V±10%, 50Hz ± 2%
3kVA/50kV AC Hipot Test Set Withstand Voltage Test
HV Hipot
Wooden Case
ISO, SGS
China
9030332000
Product Description
3kVA/50kV AC Hipot Test Set Withstand Voltage Tester




General 


AC Hipot testing is the effective and direct way to test insulation strength for electric equipment, apparatus or machines. It checks dangerous flaws which assure electric equipment continuous working. Typical applications include testing of transformers, switchgear, cables, capacitors, aerial motors platforms, hot sticks bucket bricks, vacuum bottles and other related equipment like vacuum interrupters, blankets, ropes, gloves, hydraulics hose, instruments transformers generators.



Features

1. Digital display panel mounted controls & indicators with easy to read legend. 
2. Monitoring high voltage side voltage,low voltage side current and indicator of zero, power, working start,timing.
3. Over-current protection,zero-starting protection,sound and light alarm.
4. Continuously variable output from zero to full voltage.
5. Adjustable over current protection,with trip levels variable from 0 to 100%.
6. With new type time relay,time rang is more wider (1S ~ 99H).
7. Using the latest current relay, more accurate and reliable.
8. Light weight,small size,easy to move.
 


Technical Specifications
 
Input AC220V ± 10%
Frequency50Hz ± 1
Output0-50kV, AC RMS ;
Rating100%Rated-1minute, 50%-continuous
Capacity 3kVA 
HV SourceDry type testing transformer
Output controlManual control
Voltage accuracy≤ 1.5% (F.S)
Current Accuracy≤ 1.5% (F.S)
Timing range 1s -99h
MeteringDigital display, kV meter: AC 0-50kV, mA meter: AC 0-60mA 
Humidity85% RH
Temperature-20ºC~50ºC