Multifunctional 3 in 1 Automatic Portable Digital Cholesterol & Hdl &Triglycerides Blood Lipids Function Analysis Meter

Price $180.00 Compare
Min Order 1 Piece
Shipping From Zhejiang, China
Popularity 300 people viewed
Quantity
+-
 

Hangzhou Soy MedTech Co., Ltd.

VIP   Audited Supplier 4 years
Profile Certified by SGS/BV
LPM-101
For External Use
No
Customized
Human Health Analyzer
Middle-aged and Old
CE
Reflectance Photometer
Whole Blood(Capillary and Venous )
AAA Battery
Approximately 1,000 Tests
Mmol/L, Mg/Dl
5 Minutes After Displaying Results
2 Years
4 Years
1 Years
120 Seconds
90g
500 Records
Lysun
34.5*32.6*24cm
TC:2.59-12.93 ; HDL:0.39-2.59 ;TG:0.51-7.34 mmol/L
China
Product Description
Product Description

   Introduction

      The Blood Lipid Analysis System is intended for the quantitative determination of Total Cholesterol (TC), High Density Lipoprotein Cholesterol (HDL),Triglycerides(TG), and the calculated ratio of TC/HDL and Low Density Lipoprotein Cholesterol(LDL) in capillary blood, venous whole blood, plasma and serum.
      The Blood Lipid Analysis System provides results.The Blood Lipid meter can storeup to 500 results and records.The meter can be operated by charging battery.

 

Product Description
*Rechargeable
   
 Built-in 1200mAh Li-ionbattery and support long-endurance
*Bluetooth
   
Use Bluetooth to sync data with phone and bluetooth printer conveniently
*Rapid Test
     Test result in 120 seconds
*Mobile Application
     Easy management onphone APPs
*Micro Specimen
     35 uL of whole blood (capillary and venous ), plasma and serum
*Program Update
     Automatically update meter program to latest version

 

Main Features of Blood Lipids Monitoring System

· Tiny blood sample
· Fast measuring time
· Easy to read large LCD
 
To ensure accurate results:

• Read instructions carefully and complete any necessary training before use.
• Use the code chip that is included in each box of test strips.
• Only use the Blood Lipid Test strips with the Blood Lipid Meter.
• For in vitro diagnostic use only. Your Blood Lipid Analysis system is only to be
used outside the body for testing purposes.
• Keep out of reach of children.


Specification

MethodologyReflectance Photometer
Measurement RangeTC:2.59-12.93 mmol/L (100-500 mg/dL,1mmol/L=38.66mg/dL)
HDL:0.39-2.59 mmol/L(15-100mg/dL,1mmol/L=38.66mg/dL)
TG:0.51-7.34mmol/L(45-650 mg/dL, 1mmol/L=88.6 mg/dL)
Specimenwhole blood(capillary and venous ),plasma and serum
Power Source1200mAh built-in lithium battery
Battery EnduranceAfter cycle charge 300 times,electric quantity reduce 30%
Units of Measurementmmol/L, mg/dL
Memory500 records
Automatic Shut Off5 minutes after last use
 
Meter Size135*66*19mm(L*W*H)
weight90g
Meter Storage Conditions0-55°C;≤ 90% RH
System Operating Conditions10-35°C; s 90% RH ;height <seal-level 2000m
Test strip Storage Conditions2~30ºC;≤ 90% RH
Warranty Period2 years
Meter Shelf Life4 years
Test Strip Shelf Life1 years