AC 11KV 2000KW
11kv 2000kw High Voltage Load Bank for Genset Test
86~106kpa
6058*2350*2591mm
5%
3%
0.5 Class
No Need Transformer
RS-485, RS-232
Continuous
Forced Air Cooling
Triumph load
Wooden Case
ISO9001: 2008
Hebei, China
9030339000
Product Description
Application
Large generator system testing in ocean engineering, drilling facilities,ship construction etc field
Factory testing for generator, static voltage characteristic test, speed characteristic test;
Marine generator overload protection test,parallel operation test,reverse power and reverse current protection test
Assist shipyard in mooring test,sea trial test
Assist with the acceptance of the vessel generator test
Eliminate the carbon deposition of generator
As the generator loading system
Periodic running test for standby generator
UPS inspection and maintenance
Ship battery charging/discharging system testing
The acceptance of new system and testing of servicing equipment
Advantage:
The ability to test critical power systems at voltages of 1.2KV to 80kV using direct-connect, High Voltage Load Bank offers engineers flexibility, time savings, cost savings, space savings and simplicity. It mainly used to commission utility, oil & gas, and industrial power systems without the need for additional transformers and cabling.





Technical Parameters
Contact:
Bruce Pan
Hebei Kaixiang Electrical Technology Co., Ltd
No 33 Wangshan Road, Shijiazhuang City,
Hebei Province, China
Tel: 0086-311-85138355 Fax: 0086-311-85138330
Cell phone 0086-13739721527
kxload.en.made-in-china.com
Our service is beyond of products, but the feeling of customers
Large generator system testing in ocean engineering, drilling facilities,ship construction etc field
Factory testing for generator, static voltage characteristic test, speed characteristic test;
Marine generator overload protection test,parallel operation test,reverse power and reverse current protection test
Assist shipyard in mooring test,sea trial test
Assist with the acceptance of the vessel generator test
Eliminate the carbon deposition of generator
As the generator loading system
Periodic running test for standby generator
UPS inspection and maintenance
Ship battery charging/discharging system testing
The acceptance of new system and testing of servicing equipment
Advantage:
The ability to test critical power systems at voltages of 1.2KV to 80kV using direct-connect, High Voltage Load Bank offers engineers flexibility, time savings, cost savings, space savings and simplicity. It mainly used to commission utility, oil & gas, and industrial power systems without the need for additional transformers and cabling.





Technical Parameters
AC11kV-2000kW High Voltage Load Bank for Genset Test | |
Rating Voltage/Frequency | 11KV, 3phase, 50HZ/60HZ |
Rated Load Power | Resistive load: 2000kW |
Installed Capacity | Resistive load: 2000kW |
Load Step | Resistive load: 6 steps, 100kw,200kw,200kw, 500kw,500kw,500kw min step: 100kW |
PF(Power Factor) | 1 |
Load Tolerance (each step) | ±5% |
Load Tolerance(overall) | ±3% |
Display Precision | 0.5 class |
Control Power | 3 phase 4 wire 380V/50Hz |
Wire Connection | Load power supply input--Copper bar (star coupling) Control power supply input--Connector-bar |
Insulation | F |
Max Protection Grade | IP55 |
Duty Cycle | Continuous |
Cooling | Forced air cooling,Horizontal inlet air,Vertical cooling |
Aeration | About 160,000 cubic meters per hour |
Casing Structure | Container, with a ladder, air inlet and outlet with mesh enclosure and protection door |
Transportation | Hoisting, there are lifting lug in top of casing |
Casing Color | Grey(RAL7035)or as per customer's requirement |
Dimension | About 6058 mm×2350mm×2591mm(length*width*height) |
Weight | About 6000kg |
Operating Environment Parameter | |
Workplace | Outdoor |
Ambient Temperature | -10ºC~+50ºC |
Relative Humidity | ≤95% |
Altitude | ≤2500 meter |
Atmospheric Pressure | 86~106kPa |
Space Required | About 14.77 square meter |
Ground load-bearing requirements | About 406kg/square meter |
Aeration Distance | 3-5meters no obstacle from air inlet, more than 3meters no obstacle from air outlet |
Safe Working Distance | For the convenience of personnel to enter, there should no obstacles 3 meters in front of control room and no obstacles 2 meters in front of maintenance room |
Brands of Main Components | |
Contactor | Xiguang |
Fuse | Chuantai |
Alloy Resistance | Kaixiang(self-developed) |
Data Processing Software | Kaixiang(self-developed) |