KDVLF
Yes
1 Year
<500mm
<900kg
Universal Testing Machine
<1000KN
0.5
Electronic Load
Dynamic Load
Needle
Computer Control
0-100Kg
AC220V
Under
Capacitive Touch Screen, Automatic Storage,etc
Ultra Low Frequency High Voltage Generator
≤ 5%
≤ 3%
0.1Hz, 0.05Hz, 0.02Hz
OEM, ODM, Obm, Software Reengineering
≤ 10ms
30kv, 40kv, 50kv, 60kv, 80kv, 90kv, etc
3%
Overvoltage Protection, etc
Electronic
KDZD
Wooden Case
25*28*40cm
Hubei, China
9030332000
Product Description




Product parameters | |
Product Name | Ultra Low Frequency High Voltage Generator |
Rated voltage | 30kV, 40kV, 50kV, 60kV, 80kV, 90kV, etc |
Measurement accuracy | 3% |
Voltage waveform distortion | ≤ 5% |
Voltage positive and negative peak error | ≤ 3% |
Output frequency | 0.1Hz, 0.05Hz, 0.02Hz |
Product Features
★Current, voltage, and waveform data are directly obtained through high-voltage side sampling, so the data is true and accurate★Overvoltage protection: When the output exceeds the set voltage limit, the instrument will shut down for protection, with an action time of less than 20 milliseconds
★Overcurrent protection: designed as a dual protection of high and low voltage, the high voltage side can be precisely shut down for protection according to the set value; When the current on the low-voltage side exceeds the rated current, shutdown protection will be implemented
★The high-voltage output protection resistor is designed inside the boost, so there is no need to connect another protection resistor externally
★For products with a voltage of over 50kv, the series combination method can achieve multiple uses for one machine, making it extremely convenient to use
★Due to the use of high and low voltage closed-loop negative feedback control circuit, there is no capacitance rise effect in the output
★Measurement accuracy: 2%
★Voltage positive and negative peak error: ≤ 3%
★Voltage waveform distortion: ≤ 5%
★Output frequency: 0.1Hz, 0.05Hz, 0.02Hz
★Power supply: AC 50Hz, 220V ± 5% (generator: AC 50Hz, 220V ± 5%)
★Test time: Handover: 60 minutes
★Prevention: 5 minutes (can run for a long time)
Model no | Output Voltage/ Current (Peak) | Load Capacity | Control Unit | Booster(Tank) | Power | ||
Capacitance/ Freuency | Net Dim. (cm) | Net Wt (kg) | Net Dim. (cm) | Net Wt (kg) | |||
KDVLF-40 | 40kV/20mA | 0.1Hz-0.01Hz Auto Variable Capacity:≤10µF | 40×31×20 | 6 | 29x15×35 | 25 | 1200W |
KDVLF-50 | 50kV/20mA | 0.1Hz-0.01Hz Auto Variable Capacity:≤10µF | 40×31×20 | 6 | 29x15×35 | 25 | 1500W |
KDVLF-60 | 60kV/59mA | 0.1Hz-0.01Hz Auto Variable Capacity:≤5µF at 60kV; | 40×31×20 | 6 | 45×19×36 | 45 | 2000W |
KDVLF-80 | 80kV/59mA | 0.1Hz-0.01Hz Auto Variable Capacity:≤5µF at 80kV; Capacity:≤10µF for single booster (40/40kV) | 40×31×20 | 6 | 29x15×35 | 25 | 3000W |
36x19×45 | 45 | ||||||
KDVLF-90 | 90kV/59mA | 0.1Hz-0.01Hz Auto Variable Capacity:≤5µF at 90kV; Capacity:≤10µF for single booster (40/50kV) | 40×31×20 | 6 | 29x15×35 | 25 | 3500W |
36x19×45 | 45 |
Function comparison of VLF series models
Output (Peak) | Structure | Model no | AC Withstand Voltage Test | Tan Delta Test | PD Test | Capacity (μF) | Insulation Resistance Test (IR) |
30KV | 1*Controller 1*30KV Booster 1*Capacitor | KDVLF-30 | √ | X | X | X | X |
KDVLF-30A | √ | √ | X | √ | √ | ||
KDVLF-30B | √ | X | √ | √ | X | ||
KDVLF-30C | √ | √ | √ | √ | √ | ||
40KV | 1*Controller 1*40KV Booster 1*Capacitor | KDVLF-40 | √ | X | X | X | X |
KDVLF-40A | √ | √ | X | √ | √ | ||
KDVLF-40B | √ | X | √ | √ | X | ||
KDVLF-40C | √ | √ | √ | √ | √ | ||
50KV | 1*Controller 1*50KV Booster 1*Capacitor | KDVLF-50 | √ | X | X | X | X |
KDVLF-50A | √ | √ | X | √ | √ | ||
KDVLF-50B | √ | X | √ | √ | X | ||
KDVLF-50C | √ | √ | √ | √ | √ | ||
60KV | 1*Controller 1*60KV Booster 1*Capacitor | KDVLF-60 | √ | X | X | X | X |
KDVLF-60A | √ | √ | X | √ | √ | ||
KDVLF-60B | √ | X | √ | √ | X | ||
KDVLF-60C | √ | √ | √ | √ | √ | ||
70KV | 1*Controller 1*30KV Booster 1*40KV Booster 1*Capacitor | KDVLF-70 | √ | X | X | X | X |
KDVLF-70A | √ | X | √ | √ | X | ||
80KV | 1*Controller 1*30KV Booster 1*50KV Booster 1*Capacitor, or 1*Controller 2*40KV Booster 1*Capacitor | KDVLF-80 | √ | X | X | X | X |
KDVLF-80A | √ | √ | X | √ | √ | ||
KDVLF-80B | √ | X | √ | √ | X | ||
KDVLF-80C | √ | √ | √ | √ | √ | ||
90KV | 1*Controller 1*40KV Booster 1*50KV Booster 1*Capacitor | KDVLF-90 | √ | X | X | X | X |
KDVLF-90A | √ | √ | X | √ | √ | ||
KDVLF-90B | √ | X | √ | √ | X | ||
KDVLF-90C | √ | √ | √ | √ | √ | ||
Note: DC leakage current measurement for buyer's option (any type can add this function if required). |