JKR2-220KW
Three Phase Transducer, General Transducer, Single-phase Transducer, High Frequency Converter Transducer
Triple
V/F Control Transducer
PWM Control
Voltage
Low Voltage Variable-Frequency Drive
AC-AC Variable-Frequency Drive
Voltage Variable-Frequency Drive
Simple Type, Elevator Special, Textile Special, Constant Torque Universal Type
Aluminum Alloy
RS485/RS232 PLC
380V.440V
Squirrel-Cage Three-Phase Asynchronous Motor
It Is Recommended Not to Exceed 20 Times Per Hour.
Online /Bypass
7.5kw-680kw
22A ~1200A
DC/AC Fan
Voltage Control
Current Control
OEM
Wooden Package
RoHS package
Zhejiang Yueqing
8537101990
Product Description
300 hp motor soft starter, 220 kW three phase 240v, 415v, 480v, 690v AC motor starter, manufacturer direct sale.
Tips: Notice for soft starter
Model | GS2-220 (220v, 240v), GS3-220 (380v, 400v, 415v), GS4-220 (460v, 480v), GS6-220 (690v). | |
Capacity | 300 hp (220 kw) | |
Current | 440 amps at 380v/480v, 900 amps at 220v | |
Weight | 21 kgs | |
Dimension | 525*257*194 mm | |
Input | Voltage | Three-phase 240v, 400v, 480v, 690v AC |
Frequency | 50Hz/ 60Hz | |
Adaptive Motor | Squirrel-cage three-phase asynchronous motor | |
Starting Times | It is recommended not to exceed 20 times per hour. | |
485 Communication | DB9 interface, male plug, is RS485- | |
Control Mode |
| |
Start Mode |
| |
Stop Mode |
| |
Protective Function |
| |
Ambient | Place to be used | Indoor location with good ventilation free from corrosive gas and conductive dust. |
Altitude | Below 1000M. It has to increase the soft starter rate power when the altitude is more than 1000M. | |
Temperature | -30 +55 oC | |
Humidity | 90%RH without dew condensation. | |
Vibration | <0.5G | |
Structure | Enclosure | IP 20 |
Cooling | Natural wind cooling. |
- The installation and maintenance of the soft starter shall be carried out by qualified professional.
- Do not use high-voltage test equipment (such as megger) to test the insulation of soft starter.
- If the motor is required to run reversibly, an inverting contactor can be installed on the incoming line side. Be careful not to install it on the output side of soft starter.
- The coil-type motor rotor can be winded with appropriate starter resistance to improve the starting torque, the soft starter can also be used to start the coil-type motor. When the motor reaches the top speed and keeps stable, starting resistance shall be bypassed to reduce power loss.
- It is strictly forbidden to place the power factor compensation capacitor on the output side of the soft starter and the capacitor cannot be switched during start-up.