Product Description
Product details

Performance curve:
All performance curves are based on the measured values when a motor works under power of 380V, at a constant speed of 2900r/min.
The capability of flow and head conforms to ISO9001.
Measurement is done in 20oC air-free water of which viscosity is 1mm2/s.
The operation of pump shall refer to the performance range marked in thickened curve so as to avoid damages caused by over-load.
fault phenomenon | failure cause | elimination methods |
1.No power supply or one or two phase power supply is needed | Check all phases of power supply and restore power supply | |
2.Poor contact of ac contactor and burning of coil | Repair or replace contactors | |
can not start | 3. The power switch is not closed, malfunction or damaged | Close the switch and replace it if the power indicator does not turn on |
4. Thermal relay trip or damage | Check whether the motor is blocked, find out the reason and eliminate it.Manual reset is replaced if it cannot be started | |
Water level is too low | Put water in the sink | |
The motor burned | Repair or replace the motor | |
1.Line is loose | Check wiring and tighten connectors | |
2.Frequency converter malfunction | Check the fault content, check the cause according to the frequency converter manual, and restart after reset.Or disconnect the inverter power supply for a few seconds, the inverter fault reset before starting. | |
The manual is normal | 3The frequency converter is damaged | Repair or replace |
Automatic transmission failure | 4.Pressure switch damage | Repair or replace |
5The pressure transmitter is damaged | Repair or replace | |
6.Switch failure | Repair or replace | |
Pump non - suction pressure gauge pointer to beat violently | Insufficient water supply for perfusion, air leakage at the connection between pipeline and instrument | Check pipeline and bottom valve, refill water diversion. Tighten air leakage |
The pump consumes too much power | Too much flow, impeller wear | Check whether the pump shaft is bent, replace the impeller, close the outlet valve to reduce the flow |
Related products

Company Information

♦ ESTABLISHED IN THE SIXTIES
♦ ONE OF THE FIRST THROUGH THE ISO9001:2008 DOMESTIC,
INTERNATIONAL QUALITY SYSTEM CERTIFICATION
♦ SILVER MEDAL WAS AWARDED AT THE NATIONAL CONFERENCE ON THE
APPLICATION OF SPARK CUP TECHNOLOGY
♦ WIN THE NATIONAL AWARD FOR EXCELLENCE IN CIVILIZATION COMPETITION
♦ GET THE LC OF THE CHINESE GOVERNMENT
Certification

Transportation

FAQ