GPEV30-750-S1
3-Phase, 5 Wire(3pH+N+E)
295~437VAC
560VAC
60A
32kVA
0.98
750VDC
40A
30kw
-20~50ºC
Goldpower
Wooden
400 mm× 750 mm× 650mm
Shenzhen
8504401990
Product Description
Features
System Configuration
GPEV30-750-S1 charger consists of outdoor cabinet, HMI, power distribution unit, monitoring module and charging rectifier module.
Specifications




VR Factory tour:

Any inquiry,please feel free to contact us:
Tel: +86 136 0308 2585
- Goldpower 30KW mobile DC charging station designed with single gun, the maximum power is 30KW.
- Using high-performance ARM chip control, 5-inch true color LCD touch screen, easy to achieve man-machine information exchange
- With perfect protective function: input over/under voltage protection, output over current protection, output over voltage protection, output short circuit protection, over temperature protection, battery anti-reverse protection, insulation detection protection, emergency stop protection.
- The charging rectifier module adopts full bridge soft switch technology, the efficiency up to 95% or more.
- The charging rectifier module adopts active power factor compensation technology, the value up to 0.98.
- Perfect AC side lightning protection design, to adapt to thunderstorm areas.
- Ultra-low radiation, safe and reliable. Pressure level, insulation class and EMC of the charger comply to relative requirements as per NB/T 33001-2010,and part of function designed as per "Typical design of EVSE"
- The design of dustproof and waterproof up to level IP54 to meet indoor and outdoor requirements.To prevent rain directly onto the equipment, the roof needs to be installed outdoor.
System Configuration
GPEV30-750-S1 charger consists of outdoor cabinet, HMI, power distribution unit, monitoring module and charging rectifier module.
Optional Configuration | Rectifier module | Optional number | Distribution | Monitoring system | Remark |
configuration | GPR75020A | 2pcs | AC input: 3-phase 5wire,63A/4P air switch; Anti--thunder:3-phase C pole DC output: the gun mode output maximum output current is 40A(DC+,DC-) EV auxiliary power supply: 12V10A/24V5A optional(A+,A-) | Monitoring system | See the module specifications for more detailed information |
Specifications
Ambient | |||||
Parameter | Min. | Typ. | Max. | Unit | Remark |
Operating temp. range | -20 | 25 | 50 | °C | Certificated within this range |
Extreme operating temp. range | -40 | 25 | 55 | °C | -40°C ~-20°can be loaded with start, extended temperature:50 -55°C, The module outputs linearly at 4% / ° C |
Relative humidity | 5 | 95 | % | No condensation on the surface | |
Altitude | 0 | 2000 | m |
Input | |||||
Parameter | Min. | Typ. | Max. | Unit | Remark |
Input mode | 3-Phase, 5 Wire (3Ph+N+E) | Note: the charger rectifier module without midcourt line | |||
Nominal input voltage range | 323 | 380 | 437 | Vac | Nominal voltage, certified within this voltage range |
Input operating voltage range | 295 | 380 | 437 | Vac | The input voltage 315-265Vac is linearly reduced from 15KW to 5KW by 2% / V |
Max. input voltage | 560 | Vac | The module could not work but can't be damaged under this input voltage | ||
Max. input current | 60 | A | Low voltage full load ,each phase | ||
Max. input power | 32 | KVA | Input 323Vac,output full load. | ||
Soft start time | 5 | 15 | S | The nominal input voltage range rises to the set value of the output voltage. | |
Power factor | >0.98 | Rated input, full load output | |||
>0.97 | Rated input, half load output | ||||
Input current harmonic | THD<5% | Rated input, full load output | |||
THD<10% | Rated input, half load output | ||||
Grounding method | Protective ground to the power supply case |
Output | |||||
Parameter | Min. | Typ. | Max. | Unit | Remark |
Rated output voltage | 750 | Vdc | |||
Rated output voltage range | 300 | 750 | Vdc | Certificated within this output voltage range | |
Rated output current | 2 | 40 | A | ||
Rated output power | 30 | KW | |||
Stabilized voltage precision | -0.5 | +0.5 | % | ||
Ripple effective value | 1 | % | |||
Dynamic response time | 200 | us | |||
Dynamic response overshoot | -0.5 | +0.5 | % | ||
Efficiency | 95.8 | % | |||
Noise | 65 | dB(A) | |||
Current-sharing | -5 | 5 | % | Tested when the output current more than 50% | |
Cooling | Forced air cooling |
Others requirements | |||||
Parameter | Min. | Typ. | Max. | Unit | Remark |
Output current error | -1 | 1 | % | ||
Output voltage error | -0.5 | 0.5 | % | ||
DC meter error | 0.5 | Level | |||
Low voltage auxiliary power supply | 24±1% | Vdc | Optional output 5A | ||
12±1% | Vdc | Optional output 10A | |||
Input cable length | 7 | m | Optional length | ||
Charging cable length | 5 | m | Optional length(don't contain the length of gun) | ||
Charging gun interface | Comply to the latest national requirements of GB/T20234.3-2015 |
Mechanical | |
Dimension | (W×H×D)400 mm×750 mm×650mm |
Weight | ≤60Kg(including module) |




VR Factory tour:

Any inquiry,please feel free to contact us:
Tel: +86 136 0308 2585