SDS
Cardiac Stent
Metal
Medical
Disposable
ISO13485
Adult
Without Needle
Ethylene Oxide Steri
Nylon
142cm
Two Years
Both with Logo Printing and Without
Kossel
Cryovial & Carton
Diameter from 2.0mm to 5.0mm
Suzhou China
90183900
Product Description
Company Profile


Kossel Medtech has the strong technical team and complete production line to develop andproduce stents. These stents can be used in cardiovascular and cerebrovascular, peripheral vascular and non vascular (esophagus, airway and biliary). KosselMedtech can provide manufacturing and development services of these products to customer.
OEM/ODM services:


Stent
1.Cobalt chromium alloy material provides a persistent support force and better fatigue resistance
2.An extreme low profile makes it easier to cross the stenosis lesions and ensure an excellent crossability.
3.Mush structure and low shrinkage rate of stent ensure accurate release.
Delivery System
The advanced laser bonding technology ensures that the balloon has a minimum profile and a better crossing ability.
Tip laser forming technology enhances the performance of crossing the stenosis lesions.
Specification
Size Matrix of Coronary Stent System
ISO 9001 13485 Certificate

Production Line







Kossel Medtech has the strong technical team and complete production line to develop andproduce stents. These stents can be used in cardiovascular and cerebrovascular, peripheral vascular and non vascular (esophagus, airway and biliary). KosselMedtech can provide manufacturing and development services of these products to customer.
OEM/ODM services:

1.Laser cutting (316L/ L605/304T/ Nitinol/MP35N etc.)
2.Heat treatment
3.Electrochemical polishing
4.Stents griping

Stent
1.Cobalt chromium alloy material provides a persistent support force and better fatigue resistance
2.An extreme low profile makes it easier to cross the stenosis lesions and ensure an excellent crossability.
3.Mush structure and low shrinkage rate of stent ensure accurate release.
Delivery System
The advanced laser bonding technology ensures that the balloon has a minimum profile and a better crossing ability.
Tip laser forming technology enhances the performance of crossing the stenosis lesions.
Specification
Size Matrix of Coronary Stent System
L/mm D/mm | 8 | 12 | 13 | 15 | 16 | 18 | 20 | 21 | 23 | 24 | 28 | 29 | 33 | 38 | 40 |
2.0 | √ | √ | √ | √ | √ | √ | √ | √ | √ | √ | - | - | - | - | - |
2.25 | √ | √ | √ | √ | √ | √ | √ | √ | √ | √ | - | - | - | - | - |
2.5 | √ | √ | √ | √ | √ | √ | √ | √ | √ | √ | √ | √ | √ | √ | √ |
2.75 | √ | √ | √ | √ | √ | √ | √ | √ | √ | √ | √ | √ | √ | √ | √ |
3.0 | √ | √ | √ | √ | √ | √ | √ | √ | √ | √ | √ | √ | √ | √ | √ |
3.5 | √ | √ | √ | √ | √ | √ | √ | √ | √ | √ | √ | √ | √ | √ | √ |
4.0 | √ | √ | √ | √ | √ | √ | √ | √ | √ | √ | √ | √ | √ | √ | √ |
4.5 | √ | √ | √ | √ | √ | √ | √ | √ | √ | √ | √ | √ | √ | √ | √ |
5.0 | √ | √ | √ | √ | √ | √ | √ | √ | √ | √ | √ | √ | √ | √ | √ |
ISO 9001 13485 Certificate

Production Line




