TD1880 Advanced High Precision Multifunction Calibrator

Price $75000.00 Compare
Min Order 1 Piece
Shipping From Hunan, China
Popularity 378 people viewed
Quantity
+-
 

Tunkia Co., Ltd.

VIP   Audited Supplier 4 years
Profile Certified by SGS/BV
TD1880
24 Hours
365 Days
Portable
Digital
0.005%
Electronic Meter
AC
USB
1999999
AUTO/MAN RANGZ
Capacitance
LCD
TUNKIA
Aviation Packaging
Chn
9030899090
Product Description
TD1880 High-Precision Multi-Product Calibrator

Introduction
  1. TD1880, a wide-range, multi-value and high-precision calibrator, can accurately output ultra-precision AC/DC voltage, current, phase adjustment and power, and also has the functions of pulse output and simulating DC resistance, thermocouple (TC), thermal resistance (RTD) and capacitance. Applied to calibrate 6½ and below digits multimeters or other electrical measuring instruments.

Reference
  1. JJG 124-2005 Verification Regulation of Amperemeters, Voltmeters, Wattmeters and Ohmmeters.
  2. JJF 1587-2016 Calibration Specification for Multimeters
  3. JJF 1284-2011 Calibration Specification of Calibrators for Electrical Meters
  4. JJF 1638-2017 Calibration specification of multifunctional standard source

Features
  1. Electrical Parameters Output: Voltage is up to 1100 V, current is up to 20.5 A at a frequency 10 Hz ~ 500 kHz.
  2. Resistance Simulation: Continuously variable range, 1 Ω ~ 1100 MΩ, pulse output range: 1 Hz ~ 2 MHz.
  3. The output current has high stability (the typical value is better than 10 ppm/h) and high accuracy (the typical value is 50 ppm/a), and its measurement accuracy is higher than the international similar products.
  4. Value Adjustment Method: Fixed-point, rotary encoder, step and potentiometer (option).
  5. Output Switch: The output can be turned on/off arbitrarily by one-touch operation.
  6. TC and RTD simulation: Support for simulation of up to 8 types of TC and 6 types of RTD.  
  7. Strong load capacity of AC, can drive various types of analogue meters and digital meters, so the applicable range of measured instruments is very wide.
  8. The protection of voltage and current sources ensures high reliability under complex conditions.
  9. Excellent Human-Computer Interaction: Large LCD touch screen display, touch and button operation modes, easy for users to measure manually.
  10. Transmitter Measurement (Option): Measure the secondary DC signal of the transmitters.
  11. Proprietary Software (Option): Support the calibration of the checked meters by semi-automatic or full-automatic, data management and report export.

Specification
AC Voltage Output
RangeResolutionFrequency (Hz)Accuracy (k = 2, ppm*RD +μV)Max. Load
Current (mA)
90 Days
(23 ±5) °C
1 Year
(23 ±5) °C
30 mV100 nV10 ≤ F≤ 45 600 + 6800 + 650
45 < F < 40080 + 5100 + 5
400 < F < 10 k80 + 10100 + 10
10 k < F < 20 k160 + 10200 + 10
20 k < F < 50 k800 + 101000 + 10
50 k < F < 100 k2800 + 123500 + 12
100 k < F < 500 k6000 + 508000 + 50
100 mV1 μV10 ≤ F≤ 45 250 + 8300 + 850
45 < F < 40080 + 5100 + 5
400 < F < 10 k80 + 10100 + 10
10 k < F < 20 k80 + 10200 + 10
20 k < F < 50 k280 + 10350 + 10
50 k < F < 100 k640 + 10800 + 10
100 k < F < 500 k1600 + 702000 + 70
300 mV1 μV10 ≤ F≤ 45 250 + 8300 + 8100
45 < F < 10 k80 + 10100 + 10
10 k < F < 20 k80 + 10200 + 10
20 k < F < 50 k280 + 10350 + 10
50 k < F < 100 k640 + 10800 + 10
100 k < F < 500 k1600 + 702000 + 70

1 V
10 μV10 ≤ F≤ 45 250 + 50300 + 50100
45 < F < 40040 + 2050 + 20
400 < F < 10 k80 + 20100 + 20
10 k < F < 20 k160 + 20200 + 20
20 k < F < 50 k280 + 20350 + 20
50 k < F < 100 k640 + 20800 + 20
100 k < F < 500 k2000 + 6002400 + 600
3 V10 μV10 ≤ F≤ 45 250 + 50300 + 50100
45 < F < 40040 + 5050 + 50
400 < F < 2 k64 + 5080 + 50
2 k < F < 10 k80 + 50100 + 50
10 k < F < 20 k160 + 50200 + 50
20 k < F < 50 k280 + 50350 + 50
50 k < F < 100 k640 + 50800 + 50
100 k < F < 500 k2000 + 6002400 + 600
10 V100 μV10 ≤ F≤ 15 250 + 30000300 + 30000100
15 < F < 45250 + 650300 + 650
45 < F < 40040 + 15050 + 150
400 < F < 2 k64 + 15080 + 150
2 k < F < 10 k80 + 150100 + 150
10 k < F < 20 k160 + 150200 + 150
20 k < F < 50 k280 + 150350 + 150
30 V100 μV10 ≤ F≤ 15 250 + 80000300 + 30000250
15 < F < 45250 + 650300 + 650
45 < F < 40040 + 50050 + 500
400 < F < 2 k64 + 50080 + 500
2 k < F < 10 k80 + 500100 + 500
10 k < F < 20 k160 + 500200 + 500
20 k < F < 50 k280 + 500350 + 500
100 V1 mV15 < F < 45250 + 2000300 +2000250
45 < F < 40040 + 100050 +1000
400 < F < 2 k64 + 100080 + 1000
2 k < F < 10 k80 + 1000100 + 1000
10 k < F < 20 k160 + 1000200 + 1000
20 k < F < 50 k280 + 1000350 + 1000
300 V1 mV15 < F < 45250 + 6000300 + 6000100
45 < F < 40050 + 500050 + 5000
400 < F < 2 k80 + 500080 + 5000
2 k < F < 10 k80 + 5000100 + 5000
10 k < F < 20 k160 + 5000200 + 5000
20 k < F < 50 k280 + 5000350 + 5000
1000 V10 mV
 
45 ≤ F≤ 400 80 + 10000100 + 1000030
400 < F < 2 k96 + 10000120 + 10000
2 k < F < 10 k120 + 10000150 + 10000
  1. Output Range: 3 mV ~ 1100 V; Display: 7 digits;
  2. Distortion: <0.5 %;<1 % @ 10 mV…1 V ranges
  3. Protection: Short-circuit protection, overload protection.


AC Current Output
RangeResolutionFrequency (Hz)Accuracy (k = 2, ppm*RD +μV)Max. Load
Current (mA)
90 Days
(23 ±5) °C
1 Year
(23 ±5) °C
300 μA1 nA10 ≤ F≤ 20400 + 0.2500 + 0.230
20 < F < 45300 + 0.1350 + 0.1
45 < F < 400240 + 0.1300 + 0.1
400 < F < 2 k320 + 0.2400 + 0.2
2 k < F < 10 k400 + 0.5500 + 0.5
10 k < F < 20 k4000 + 0.65000 + 0.6
20 k < F < 50 k6400 + 0.78000 + 0.7
1 mA10 nA10 ≤ F≤ 20400 + 0.5500 + 0.530
20 < F < 45200 + 0.1250 + 0.1
45 < F < 400160 + 0.1200 + 0.1
400 < F < 2 k160 + 0.2200 + 0.2
2 k < F < 10 k240 + 0.5300 + 0.5
10 k < F < 20 k2400 + 0.63000 + 0.6
20 k < F < 50 k5600 + 0.77000 + 0.7
3 mA10 nA10 ≤ F≤ 20400 + 1.5500 + 1.530
20 < F < 45200 + 0.1250 + 0.1
45 < F < 400160 + 0.1200 + 0.1
400 < F < 2 k160 + 0.2200 + 0.2
2 k < F < 10 k240 + 0.5300 + 0.5
10 k < F < 20 k1600 + 0.62000 + 0.6
20 k < F < 50 k4800 + 0.76000 + 0.7
10 mA100 nA10 ≤ F≤ 20400 + 5500 + 530
20 < F < 45200 + 0.5250 + 0.5
45 < F < 40080 + 0.5100 + 0.5
400 < F < 2 k160 + 1200 + 1
2 k < F < 10 k400 + 2500 + 2
10 k < F < 20 k1600 + 32000 + 3
20 k < F < 50 k4800 + 46000 + 4
30 mA100 nA10 ≤ F≤ 20400 + 15500 + 1530
20 < F < 45200 + 2250 + 2
45 < F < 40080 + 2100 + 2
400 < F < 2 k160 + 3200 + 3
2 k < F < 10 k400 + 5500 + 5
10 k < F < 20 k1600 + 62000 + 6
20 k < F < 50 k4800 + 76000 + 7
100 mA1 μA10 ≤ F≤ 20400 + 50500 + 5030
20 < F < 45200 + 5250 + 5
45 < F < 40040 + 550 + 5
400 < F < 2 k80 + 10100 + 10
2 k < F < 10 k160 + 20200 + 20
10 k < F < 20 k800 + 301000 + 30
20 k < F < 30 k2400 + 403000 + 40
30 k < F < 50 k5000 + 406000 + 40
1 A10 μA10 ≤ F≤ 20400 + 500500 + 50015
20 < F < 45200 + 20250 + 20
45 < F < 40040 + 5050 + 50
400 < F < 2 k50 + 10050 + 100
2 k < F < 10 k160 + 500200 + 500
10 k < F < 20 k800 + 6001000 + 600
20 k < F < 30 k2400 + 7003000 + 700
3 A10 μA10 ≤ F≤ 20400 + 1500500 + 150010
20 < F < 45200 + 100250 + 100
45 < F < 40040 + 10050 + 100
400 < F < 2 k80 + 100100 + 100
2 k < F < 10 k160 + 500200 + 500
10 A100 μA45 < F < 40040 + 20050 + 2002.5
400 < F < 2 k80 + 200100 + 200
2 k < F < 10 k160 + 500200 + 500
20.5 A100 μA 45 ≤ F≤ 40080 + 600100 + 6002
400 < F < 2 k80 + 600100 + 600
2 k < F < 5 k160 + 1500200 + 1500
  1. Output Range: 30 μA ~ 20.5 A; Display: 7 digits;
  2. Distortion: <0.5 %;<1 % @ 300 μA…10 mA ranges
  3. Protection: Short-circuit protection, overload protection.

DC Voltage Output
RangeAccuracy (K = 2) (ppm*RD + μV)Max. Load Current
(mA)
Ripple Coefficient
(%)
24 Hours90 Days1 Year
30 mV15 + 224 + 230 + 250< 0.5
100 mV12 + 220 + 225 + 250< 0.5
300 mV10 + 216 + 220 + 2100< 0.5
1 V10 + 216 + 220 + 2100< 0.5
3 V8 + 512 + 515 + 5100< 0.5
10 V8 + 1012 + 1015 + 10100< 0.5
30 V8 + 2012 + 2015 + 20250< 0.5
100 V10 + 10016 + 10020 + 100250< 0.5
300 V10 + 30016 + 30020 + 300100< 0.5
1000 V10 + 150016 + 150020 + 150030< 0.5
  1. Output Range: ±(3 mV ~ 1100 V); Resolution: 0.0005 %*RG; Display: 7 digits
  2. Range Switching: Automatic or Manual.

DC Current Output
RangeAccuracy (K = 2) 
(ppm*RD + ppm*RG)
Max. Load Voltage
 (V)
Ripple Coefficient
(%)
24 Hours
 
90 Days
 
1 Year
30 μA50 + 0.0180 + 0.01100 + 0.0111< 0.5
100 μA50 + 0.0280 + 0.02100 + 0.0211< 0.5
300 μA50 + 0.0280 + 0.02100 + 0.0211< 0.5
1 mA25 + 0.0540 + 0.0550 + 0.0511< 0.5
3 mA25 + 0.0540 + 0.0550 + 0.0511< 0.5
10 mA25 + 0.240 + 0.250 + 0.211< 0.5
30 mA25 + 0.540 + 0.550 + 0.511< 0.5
100 mA25 + 140 + 150 + 111< 0.5
1 A25 + 2040 + 2050 + 204< 0.5
3 A25 + 5040 + 5050 + 504< 0.5
10 A25 + 20040 + 20050 + 2004< 0.5
20.5 A30 + 60048 + 60060 + 6003.5< 0.5
  1. Output Range: ±(3 μA ~ 20.5 A); Resolution: 0.0005 %*RG; Display: 7 digits
  2. Range Switching: Automatic or Manual.

AC/DC Power Output
DC PowerRangeCombination of DC voltage range and DC current range.
AccuracyDC voltage accuracy + DC current accuracy.
AC Power
(45 Hz ~ 65 Hz)
 
RangeCombination of 30 V...300 V range and 10 mA…30 A range.
AccuracyRange of 10 mA…30 mA: 0.05 %*FS
Range of 100 mA…30 A: 0.02 %*FS
Power Factor-1.0000…0.0000…+1.0000
  1. Active Power (|cosφ| ≥0.5), Reactive Power (|sinφ| ≥0.5)

Capacitance
RangeAccuracy (k = 2) (%*RD+ nF or μF)ResolutionAllowable Frequency
1.1 nF ~ 3.2999 nF0.5 + 0.04 nF0.1 pF10 Hz ~ 3 kHz
3.3 nF ~ 10.9999 nF0.25 + 0.04 nF0.1 pF10 Hz ~ 1 kHz
11 nF ~ 32.9999 nF0.25 + 0.4 nF0.1 pF10 Hz ~ 1 kHz
33 nF ~ 109.999 nF0.25 + 0.4 nF1 pF10 Hz ~ 1 kHz
110 nF ~ 329.999 nF0.25 + 0.3 nF1 pF10 Hz ~ 1 kHz
330 nF ~ 1.09999 μF0.25 + 1 nF10 pF10 ~ 600 Hz
1.1 μF ~ 3.29999 μF0.25 + 3 nF10 pF10 ~ 300 Hz
3.3 μF ~ 10.9999 μF0.25 + 10 nF100 pF10 ~ 150 Hz
11 μF ~ 32.9999 μF0.40 + 30 nF100 pF10 ~ 120 Hz
33 μF ~ 109.999 μF0.45 + 100 nF1 nF10 ~ 80 Hz
110 μF ~ 329.999 μF0.45 + 300 nF1 nF0 ~ 50 Hz
330 μF ~ 1.09999 mF0.45 + 1 μF10 nF0 ~ 20 Hz
1.1 mF ~ 3.29999 mF0.45 + 3 μF10 nF0 ~ 6 Hz
3.3 mF ~ 10.9999 mF0.45 + 10 μF100 nF0 ~ 2 Hz
11 mF ~ 30 mF0.75 + 30 μF100 nF0 ~ 0.6 Hz

Resistance
RangeAllowable CurrentAccuracy (k = 2), ppm*RD +Ω
24 Hours90 Days
 
1 Year
10 Ω1 mA ~ 150 mA20 + 0.0132 + 0.0140 + 0.01
20 Ω1 mA ~ 150 mA15 + 0.01524 + 0.01530 + 0.015
100 Ω1 mA ~ 80 mA12 + 0.01520 + 0.01525 + 0.015
300 Ω1 mA ~ 40 mA12 + 0.0220 + 0.0225 + 0.02
1 kΩ1 mA ~ 20 mA12 + 0.0220 + 0.0225 + 0.02
3 kΩ0.1 mA ~ 6 mA12 + 0.220 + 0.225 + 0.2
10 kΩ0.1 mA ~ 2 mA12 + 0.220 + 0.225 + 0.2
30 kΩ10 μA ~ 600 μA15 + 124 + 130 + 1
100 kΩ10 μA ~200 μA15 + 124 + 130 + 1
300 kΩ1 μA ~ 60 μA17 + 1028 + 1035 + 10
1 MΩ1 μA ~ 20 μA17 + 1028 + 1035 + 10
3 MΩ250 nA ~ 6 μA30 + 15048 + 15060 + 150
10 MΩ250 nA ~ 2 μA65 + 250104 + 250130 + 250
30 MΩ25 nA ~ 600 nA125 + 2.5 k200 + 2.5 k250 + 2.5 k
100 MΩ25 nA ~ 200 nA250 + 3 k400 + 3 k500 + 3 k
300 MΩ2.5 nA ~ 60 nA1,5 k + 0.1 M2.4 k + 0.1 M3 k + 0.1 M
1000 MΩ1 nA ~ 20 nA7.5 k + 0.5 M12 k + 0.5 M15 k + 0.5 M
  1. Output Range of Resistance: 0 Ω ~ 1100 MΩ; Resolution: 0.0004 %*RG; Display: 7 digits

Thermal Resistance (RTD)
TypeTemperature Range C)Accuracy (k = 2) C)
90 Days1 Year
Pt385, 100 Ω-200 ~ 00.050.05
0 ~ 3000.080.08
300 ~ 8500.120.12
Pt385,200 Ω-200 ~ 2500.040.04
250 ~ 6300.100.15
Pt385,500 Ω-200 ~ -300.360.40
-30 ~ 6300.100.11
Pt385,1000 Ω-200 ~ 00.0270.03
0 ~ 3000.0540.060
300 ~ 6000.0630.070
CU50-50 ~ 1500.090.09
CU100-50 ~ 1500.0450.045

Thermocouple (TC)
TypeTemperature Range C)Accuracy (k = 2) C)
90 Days1 Year
B410 ~ 6000.300.35
600 ~ 9000.300.31
900 ~ 18000.260.30
E-200 ~ 00.100.11
0 ~ 6000.070.08
600 ~ 10000.090.10
J-200 ~ -1000.120.13
-100 ~ 7500.090.09
750 ~ 12000.100.10
K-200 ~ -1000.150.20
-100 ~ 10000.100.10
1000 ~ 13700.120.12
N-200 ~ -1000.200.25
-100 ~ 4000.120.12
400 ~ 13000.100.12
R-50 ~ 500.300.40
50 ~ 3000.280.32
300 ~ 10000.220.23
1000 ~ 17500.250.25
S-50 ~ 500.300.40
50 ~ 3000.310.34
300 ~ 10000.240.24
1000 ~ 17500.220.23
T-200 ~ -1000.170.25
-100 ~ 00.080.11
0 ~ 4000.080.08



Pulse
  1. Frequency Range: 1 Hz ~ 2 MHz, TTL Level
  2. Resolution: 0.001 %*RG
  3. Accuracy: ±(0.002 %*RD + 20 μHz)
  4. Jitter: <20 ns

DC Small Signal Measurement (Option)
  1. Range: 1 V, 10 V, 2 mA, 20 mA
  2. Measuring Range: ± (0 ~12 V);± (0 ~ 24 mA)
  3. Accuracy: ±(0.006 %*RD + 0.004 %*RG)
  4. Notes: Applied to measure the secondary DC signal of the transmitters.

Company Profile
 