TD4530 Three-Phase and DC Field Calibrator

Price $20000.00 Compare
Min Order 1 Set
Shipping From Hunan, China
Popularity 354 people viewed
Quantity
+-
 

Tunkia Co., Ltd.

VIP   Audited Supplier 4 years
Profile Certified by SGS/BV
TD4530
Electromagnetic Instrument
Electricity
Non-Customized
0.02, 0.05
1 V~660 V
20 mA~30 A
0.1 A~6 A
45 Hz~70 Hz
10 mV~1100 V
0.1 mA~30 A
2nd~21th
TUNKIA
Package for Exporting
22kg; 470 mm(W) x 470 mm(D) x 190 mm(H)
China
Product Description
TD4530 Three-Phase and DC Field Calibrator

1. Summary

TD4530 is a multi-function 3PH power calibrator. Class 0.02 / class 0.05 available. It integrates AC/DC power output function, 3PH measuring function, harmonic function, transmitter test function, U4th voltage output function, AC energy meter test function. Can be used to calibrate AC/DC voltmeter, AC/DC ammeter, AC/DC power meter electric energy meter and transmitter, etc.
 

2. Features

  1. 3PH AC voltage output:1 V~660 V (UAB Max 1100 V)
  2. 3PH AC current output:20 mA~30 A
  3. 3PH voltage meter:6 V~456 V;
  4. 3PH current meter:0.1 A~6 A
  5. Frequency:45 Hz~70 Hz
  6. U-I phase:~360°
  7. DC voltage output:10 mV~1100 V
  8. DC current output:0.1 mA~30 A
  9. Accuracy class: 0.02, 0.05.
  10. 2nd~21st harmonic output
  11. Transmitter test function
  12. U4th AC voltage output function(option)
  13. Energy meter test function(option)
  14. Test software(option)
 

3. Application



 

4. Characteristics

Wide Output
  1. It can meet most single-phase / three-phase meters or DC meters.
 
Wide Input
  1. It can meet most single-phase / three-phase source.


 
Multiple Output Mode
  1. "Direct output"mode,User can set output value by physical key or touch screen.
  2. Three-phase unit adjustment or single phase adjustment.
  1. "Rotary Knob"mode,User can setting in clockwise direction or anticlockwise direction.
.
 
Multiple Output Mode
  1. Touch "Calibration point"of screen for "% setting".
  1. "Remote Control Box(option)",by operation of coarse tuning-fine tuning,can calibrate analog meter.




 

Harmonics Function
S/NFunction declaration
1Set amplitude of harmonic.
2Set phase of harmonic(fundamental wave).
3Choose 2nd~21st harmonics channel output.
4Oscilloscope function, user can observe voltage and current waves.
5Display frequency spectrum of harmonic by histogram.(fundament wave is 100%)

5. Specifications

5.1 Three-Phase Voltage / Current Output

Voltage RangeResolutionStability
( %/min )
Accuracy
±(ppm of reading + ppm of range) [1]
Max
Burden (mA)
Class 0.05Class 0.02Class 0.05Class 0.02
15 V0.1 mV0.010.005300 + 200120 + 80500
30 V0.1 mV0.010.005300 + 200120 + 80500
60 V0.1 mV0.010.005300 + 200120 + 80150
75 V0.1 mV0.010.005300 + 200120 + 80150
150 V1 mV0.010.005300 + 200120 + 8050
300 V1 mV0.010.005300 + 200120 + 8050
600 V1 mV0.010.005300 + 200120 + 8025
750 V[2]1 mV0.010.005300 + 200120 + 8025
1000 V[2]10 mV0.010.005300 + 200120 + 8025
Note [1] : (ppm = parts per million) (e.g.,10ppm = 0.001%). Note [2]:750 V,1000 V as UAB.
 
Current RangeResolutionStability
( %/min )
Accuracy
±(ppm of reading + ppm of range) [1]
Max
Burden (V)
Class 0.05Class 0.02Class 0.05Class 0.02
200 mA1 μA0.010.005300 + 200120 + 8050
500 mA1 μA0.010.005300 + 200120 + 8020
1 A10 μA0.010.005300 + 200120 + 8020
2 A10 μA0.010.005300 + 200120 + 805
5 A10 μA0.010.005300 + 200120 + 805
10 A0.1 mA0.010.005300 + 200120 + 801
25 A0.1 mA0.010.005300 + 200120 + 801
  1. Three-phase voltage output: 1 V~660 V(UAB Max 1100 V), Degree of distortion:< 0.5%
  2. Three-phase current output:20 mA~30 A,Degree of distortion:< 0.2%;
  3. Voltage short circuit, current open-circuit and overload protection

5.2 Frequency / Phase / Harmonic

SymmetryVoltage superior to 0.2%;Current superior to 0.5%;Phase superior to 0.5°
Frequency Range:45 Hz~70 Hz;
Adjustment fineness:0.001 Hz;
Accuracy:±0.02 Hz (class 0.05), ±0.01 Hz(class 0.02)
PhaseRange:0.000 0°~359.999 9°;
Adjustment fineness:0.001°;
Accuracy:±0.02° (class 0.05), ±0.01°(class 0.02)
Harmonic2nd~21st harmonic;
Amplitude 0~25% adjustable;
Phase 0~359.99°adjustable
 

5.3 Three-Phase Power Output

Current RangeStability
( %/min )
Accuracy
( ± %*FS)[2]
Class 0.05Class 0.02Class 0.05Class 0.02
Active power |cosφ|≥0.50.010.0050.050.02
Reactive power |sinφ|≥0.50.020.010.10.05
Apparent power0.020.010.10.05
Power factor0.020.010.10.05
Note [2] :FS= voltage range ×current range
  1. Power factor setting range:-1.000 000…0.000 000…1.000 000
 

5.4 Three-Phase Voltage / Current Input

TypeRangeResolutionAccuracy
±(ppm of reading + ppm of range) [1]
Direct InputClamp Current Input [3]
AC Voltage
ACV
57.7 V0.1 mV300 + 200--
100 V1 mV300 + 200--
220 V1 mV300 + 200--
380 V1 mV300 + 200--
AC Current
ACI
1 A10 μA300 + 200--
5 A10 μA300 + 2000.2%*RG
Note [3]:Clamp is option,if it be need, it must remark in order contract,Same as below.
  1. Voltage input:6 V~456 V,Current input:0.1 A~6 A
  2. Frequency:45 Hz~70 Hz,Accuracy:± 0.01 Hz
  3. Phase:0.000°~359.999°,Accuracy:± 0.02°
 

5.5 Three-Phase Power Input

TypeAccuracy
Direct InputClamp Current Input
Active power± 0.05%*FS± 0.2%*FS
Reactive power± 0.1%*FS± 0.5%*FS
Apparent power± 0.1%*FS± 0.5%*FS
Power factor± 0.1%± 0.5%
 

5.6 DC Voltage / Current Output

Voltage RangeResolutionStability
( %/min )
Accuracy
±(ppm of reading + ppm of range) [1]
Max
Burden (mA)
Class 0.05Class 0.02Class 0.05Class 0.02
100 mV1 μV0.0050.005300 + 200120 + 12010
1 V10 μV0.0050.005300 + 200120 + 8010
10 V0.1 mV0.0050.005300 + 200120 + 8010
30 V0.1 mV0.0050.005300 + 200120 + 80500
100 V1 mV0.0050.005300 + 200120 + 80150
300 V1 mV0.0050.005300 + 200120 + 8050
600 V10 mV0.0050.005300 + 200120 + 8025
1000 V10 mV0.0050.005300 + 200120 + 8015
 
Current RangeResolutionStability
( %/min )
Accuracy
±(ppm of reading + ppm of range) [1]
Max
Burden (V)
Class 0.05Class 0.02Class 0.05Class 0.02
100 μA1 nA0.010.005300 + 200120 + 8010
1 mA10 nA0.010.005300 + 200120 + 8010
10 mA0.1 μA0.010.005300 + 200120 + 8010
100 mA1 μA0.010.005300 + 200120 + 8010
1A10 μA0.010.005300 + 200120 + 8010
3A10 μA0.010.005300 + 200120 + 8010
10A100 μA0.010.005300 + 200120 + 8010
25A100 μA0.010.005300 + 200120 + 8010
  1. DC voltage output:10 mV~1100 V,ripple factor:< 1%;
  2. DC current output:0.1 mA~30 A,ripple factor:< 1%
  3. Voltage short circuit, current open-circuit and overload protection

5.7 DC Meter(Transmitter)

RangeMeasurement RangeAccuracyMeasurement Range of RippleAccuracy of Ripple
1 V± ( 0~1.2 ) V± 0.01%*RG0~30 mV± 1 mV
10 V± ( 0~12 ) V± 0.01%*RG0~300 mV± 10 mV
2 mA±( 0~2.4) mA± 0.01%*RG0~60 μA± 2 μA
20 mA± ( 0~24 ) mA± 0.01%*RG0~600 μA± 20 μA
  1. Response time:measurement range:0~1000 ms,accuracy:± 40 ms
 

5.8 Test Energy Meter(option)

TypeAccuracy
Class 0.05Class 0.02
Active electrical energy± 0.1%*reading± 0.05%* reading
Reactive electrical energy± 0.2%* reading± 0.1%* reading
  1. Energy pulse output:full range for 60 kHz
  2. Energy pulse input:max frequency is 1 kHz,pulse level:3 V~12 V
  3. Constant setting of Electrical energy meter:1…1000000 imp./kwh or 1…1000000 imp./ws
 

5.9 U4th Voltage Output(option)

  1. Voltage range:100 V,380 V
  2. Output range:(0~110)%*RG
  3. Accuracy:± 0.05%*RG
  4. Max output power:10 VA
  5. Frequency range:45 Hz~55 Hz
  6. The function is used to test Synchrometer.
 

6. General Specifications

Power SupplyAC ( 220 ± 22 ) V,( 50 ± 2 ) Hz
Temperature PerformanceWorking temperature:0°C~45°C;
Storage temperature:-20°C~70°C
Humidity PerformanceWorking humidity:< 80% @ 30°C,< 70% @ 40°C,< 40% @ 50°C
Storage humidity:(20%~80%) R·H,non-condensing
InterfaceRS232
 

7. Ordering Information



 
Company Profile
 

Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA