1. Summary

TS1200 is a special instrument for measuring the AC magnetic properties of electrical steel. It consists of excitation and measurement host, Epstein frame, Single Sheet Tester (optional), computer software, etc. It is suitable for comprehensive analysis of AC magnetic characteristics of electrical steel or core.
 

2. Features

  1. Electrical parameters calibration function.
  2. Measurement of magnetic field by M.C and H-Coil (optional).
  3. Maximum magnetization field reaches 30 kA/m (700 T Epstein frame).
  4. The maximum frequency can be selected to 10kHz.
  5. 2 ~ 63 harmonics influence measurement (optional).
  6. Slowly reduce amplitude demagnetization for specimen.
  7. Software controlled automatic measurement.
  8. Automatic multi-point measurement.
  9. The software has been configured with multiple measurement schemes
  10. Automatic calculates magnetic parameters and curves.
  11. Modular design, easy to upgrade or maintenance.
 

3. The Reference Standard

  1. IEC 60404-2 "Magnetic materials-Part 2 Methods of measurement of the magnetic properties of electrical steel strip and sheet by EP".
  2. IEC 60404-3 "Magnetic materials-Part 3 Methods of measurement of the magnetic properties of electrical steel strip and sheet by SST".
  3. IEC 60404-10 "Magnetic materials-Part 10-Methods of measurement of magnetic properties of electrical steel strip and sheet at medium frequencies".
 

4. Applications

 


5. Specifications of magnetic parameters

FrequencyParameterRange[1]Uncertainty (k=2) [6]Repeatability[6]
50Hz / 60HzHm5 A/m...10 kA/m / 30 kA/m [5]0.3%0.2%
Jm / BmB5  [2]... B10000 / B30000[5]0.3%0.1%
PsP0.1 [3].... P1.9 ( P1.7 )0.5%0.2%
400 HzHm5 A/m...2.5 kA/m0.5%0.2%
Jm / BmB5 [2]... B25000.5%0.2%
PsP0.1 [3].... P1.7 ( P1.5 )1.0%0.5%
1 kHzHm5 A/m...800 A/m1.0%0.3%
Jm / BmB5 [2]... B8001.0%0.3%
PsP0.1 [3].... P1.5 ( P1.0 )2.0%0.5%
2.5 kHzHm5 A/m...200 A/m1.0%0.3%
Jm / BmB5 [2]... B2001.0%0.3%
PsP0.1 [3].... P1.02.0%0.5%
10 kHzHm5 A/m...100 A/m2.0%0.5%
Jm / BmB5 [2]... B100 2.0%0.5%
PsP0.1[3].... P0.54.0%1.0%
  1. Conditions :(23 ± 5)ºC, demagnetized before measurement.
  2. Accuracy: 1%~2% deviation will occur according to the way and position of loading the sample in the measuring frame.
  3. Repeatability: put the same specimens in the specified position and keep it from moving, and measure it repeatedly for 10 times. Take the maximum or minimum value of 10 measurements minus the average value divided by the average value, and the maximum value of the two represents repeatability.
  4. Note: [1] The table only gives reference measuring points, and the indexes such as Hm, Jm/Bm, Ps that can be reached by the specimens during actual measure are related to the performance of the material, quality of the specimens, frequency, current, voltage, etc.
  5. Note: [2] B5 refers to the magnetic flux density value when the magnetic field H is 5 A/m, and the typical measuring points of non-oriented steel are in parentheses.
  6. Note: [3] P0.1 refers to the specific total loss value when flux B is 0.1T, and the typical measure point for non-oriented steel is in parentheses.
  7. Note: [4] For medium and high frequency measurment, select the corresponding Epstein frame.
  8. Note: [5] When the selected effective excitation power is 1500VA, the magnetic field can reach 30 kA/m with the corresponding Epstein frame.
  9. Note: [6] The uncertainty and repeatability are at typical measuring points, and are related to the performance of the measured material.
 

6. Specifications of Electrical Parameters

Output capabilityVoltage0.1 Vrms ~ 200 Vrms
Frequency45 Hz...1 kHz... 2.5 kHz...10 kHz (optional)
Power500 VA / 1500 VA (optional)
Current500VA0.5 mApk ~ 15 Apk 
1500VA0.5 mApk ~ 45 Apk
Harmonic2... 63 (optional)
SpecificationFrequency (Hz)Uncertainty of Effective value of voltage and current(k=2)Uncertainty of active power(k=2)
45  F  650.05%*RG [7]0.1%*FS [8]
65 < F  4000.05%*RG [7]0.15%*FS [8]
400 < F  1 k0.1%*RG [7]0.2%*FS [8]
1 k < F  2.5 k0.2%*RG [7]0.5%*FS [8]
2.5 k < F  10 k0.5%*RG [7]1.0%*FS [8]
  1. Note: [7] RG is range;
  2. Note: [8] FS= Voltage range x current range, when the phase Angle is within 75 degrees.


 

7. General Specifications

Power SupplyAC ( 220 ± 22 ) V,( 50 ± 2 ) Hz
Temperature PerformanceWorking Temperature:0°C~40°C;
Storage Temperature:-20°C~70°C
Humidity PerformanceWorking Humidity:40%~80% R·H,No condensation
Store Humidity:< 95% R·H,No condensation


8. Epstein Frame (optional)

  1. The built-in coil of air flux compensation conforms to IEC60404-2 or IEC60404-10 standards.
  2. The cutting and placement of specimens shall comply with IEC60404-2.
TypeModelLengthTurnsLumen HeightMeasurement MethodMaximum Magnetization Field Working TemperatureFrequency
Regular Epstein FrameTS7000-A25 cm700 T10 mmM.C10 kA/m0ºC~45ºC400 Hz
TS7000-B25 cm700 T10 mmM.C30 kA/m0ºC~45ºC400 Hz
TS7000-A-HM25 cm700 T10 mmM.C / H-Coil10 kA/m0ºC~45ºC400 Hz
TS7000-B-HM25 cm700 T10 mmM.C / H-Coil30 kA/m0ºC~45ºC400 Hz
Medium Frequency Epstein FrameTS701025 cm200 T5 mmM.C800 A/m0ºC~45ºC400 Hz~10 kHz
High Frequency Epstein FrameTS702025 cm100 T5 mmM.C100 A/m0ºC~45ºC10 kHz~20 kHz
  1. Note: The user shall select the corresponding Epstein frame according to the test frequency and the maximum magnetic field.
  2. Note: Select both M.C and H-coil for measurement. The host must support the M.C and H-coil methods.

9. Single Sheet Tester (optional)

TypeModelSpecimens Size
(W × L)
Specimens ThicknessMeasurement MethodMaximum Magnetization FieldWorking
Temperature
Frequency
Basic EditionTS7500500 mm × 500 mm0.1 mm~0.5 mmM.C10 kA/m0ºC~45ºC100 Hz
Upgrade EditionTS7510-A500 mm × 500 mm0.1 mm~0.5 mmM.C10 kA/m0ºC~45ºC100 Hz
TS7510-B300 mm × 300 mm0.1 mm~0.5 mmM.C10 kA/m0ºC~45ºC100 Hz
TS7510-C100 mm × 300 mm0.1 mm~0.5 mmM.C10 kA/m0ºC~45ºC100 Hz
TS7510-D30 mm × 300 mm0.1 mm~0.5 mmM.C10 kA/m0ºC~45ºC100 Hz
TS7510-A-HM500 mm × 500 mm0.1 mm~0.5 mmM.C / H-Coil10 kA/m0ºC~45ºC100 Hz
TS7510-B-HM300 mm × 300 mm0.1 mm~0.5 mmM.C / H-Coil10 kA/m0ºC~45ºC100 Hz
TS7510-C-HM100 mm × 300 mm0.1 mm~0.5 mmM.C / H-Coil10 kA/m0ºC~45ºC100 Hz
 TS7510-D-HM30 mm × 300 mm0.1 mm~0.5 mmM.C / H-Coil10 kA/m0ºC~45ºC100 Hz
  1. Note: If single sheet tester supporting H-coil is selected. The host shall support the M.C and H-coil.

10. System Configuration List

No.Item nameNumberConfigurationNote
1TS12001standard 
2TS7000 Epstein frame1standardTS7000-A (basic edition)
TS7000-B (others)
3Software1standard 
4Test Wires and Attachments1standard 
5TS7010 Medium Frequency Epstein Frame1Optional200 T, 400 Hz~10 kHz
6TS7020 High Frequency Epstein Frame1Optional100 T, 10 kHz~20 kHz
7TS7500 Single Sheet Tester1OptionalAccording to requirements
8Workbench1OptionalThird party Products
9Sartorius Electronic Balance1Optional0.1~3.2kg, Precision: 0.1g
10Computer1OptionalThird party Products