Combination Wrench
Chrome-vanadium Steel
American Type, Metric, British, German Type, European Type
Dongcheng
VDE Plastic
Common
Anti-Explosion, Ordinary, Anti-Magnetic
Manual
Folded
Colorful
Adult
VDE
Online
Bricklaying Trowel
Industrial
Electriferous
Mining
Industrial
OEM, ODM, Obm
OEM
Carton
3/8" & 1/2"
China
820540
Product Description
Insulating hand tool VDE hardware 10pcs VED Insulated Tool set Anti-electric shock



Safety Instructions:
1.To be used by certified professionals.
2.Tum power supply off before using.
3.Conduct tool inspection before use,refrain from using when damaged.
4.Choose only the tools marked with VDE GS . 1000.
5.Follow the code of work safety.
Currently,our laboratory,in hand-made tools industry,has one of the most complete and professional testing equipment.We can,in aspectss,test,manage and control our products towards machanica and plastic properties,products limits,product life span and natural enviromental impact etc.




Insulation Tool Performance Test
1.Dielectric Test
After storing tools underwater the 1000V test is conducted.
Duringthe test, no puncture, sparkover and fiashover.
2.Flame Retarancy test
The testing flame shall act upon the hand tool to be tested 10s. Thetest shall be considered as passed if the flame height on the hand toodoes not exceed 120mm during the 20s of the observation period(withdraw of testing flame).
3.lmpact Test At Extreme Low Temperatures
Hand tools of category "C"shall be conditioned in a coolincchamber for 2h at -40°C. After test , no breaks,exfoliation andcracks. (falling height 0.6 m).
4. Adhesion Test
The insulation must not come loose or slacken when under 2tensile load for 3 minutes after 168 hours in a climatic chamber at+70°C.
5. Indentation Test
After being stored for 2 hours at a temperature of 70°C, with apressure load of 20 N and a 3-minute measurement under 5.000 Vthere must be no punctures or arcing in the insulation.
6.Marking Durability Test
The marking is rubbed for 15 seconds with a rag soaked in wateand then for 15 seconds with a rag soaked in isopropylalcoholAfterward the marking shall still be legible.
https://dongchengtool.en.made-in-china.com/company Linyi Dongcheng Hardware and Tools Co Ltd.html


INSULATED TOOLS SET
ITEM | SIZE | QTY |
Insulated Combination Plier | 180mm | 1 |
Insulated Long Nose Plier | 160mm | 1 |
Insulated Diagonal Cutting Plier | 160mm | 1 |
Insulated Cable Knife With Blade Back | 195mm | 1 |
Insulated Adjustable Wrench | 200mm | 1 |
Insulated Slotted Screwdrivers | 4.0*100mm | 1 |
5.5*125mm | 1 | |
Insulated Phillips Screwdrivers | PH1*80MM | 1 |
PH2*100MM | 1 | |
Non-contact Voltage Detector | 60-100V | 1 |



1.To be used by certified professionals.
2.Tum power supply off before using.
3.Conduct tool inspection before use,refrain from using when damaged.
4.Choose only the tools marked with VDE GS . 1000.
5.Follow the code of work safety.
Currently,our laboratory,in hand-made tools industry,has one of the most complete and professional testing equipment.We can,in aspectss,test,manage and control our products towards machanica and plastic properties,products limits,product life span and natural enviromental impact etc.





Insulation Tool Performance Test
1.Dielectric Test
After storing tools underwater the 1000V test is conducted.
Duringthe test, no puncture, sparkover and fiashover.
2.Flame Retarancy test
The testing flame shall act upon the hand tool to be tested 10s. Thetest shall be considered as passed if the flame height on the hand toodoes not exceed 120mm during the 20s of the observation period(withdraw of testing flame).
3.lmpact Test At Extreme Low Temperatures
Hand tools of category "C"shall be conditioned in a coolincchamber for 2h at -40°C. After test , no breaks,exfoliation andcracks. (falling height 0.6 m).
4. Adhesion Test
The insulation must not come loose or slacken when under 2tensile load for 3 minutes after 168 hours in a climatic chamber at+70°C.
5. Indentation Test
After being stored for 2 hours at a temperature of 70°C, with apressure load of 20 N and a 3-minute measurement under 5.000 Vthere must be no punctures or arcing in the insulation.
6.Marking Durability Test
The marking is rubbed for 15 seconds with a rag soaked in wateand then for 15 seconds with a rag soaked in isopropylalcoholAfterward the marking shall still be legible.
https://dongchengtool.en.made-in-china.com/company Linyi Dongcheng Hardware and Tools Co Ltd.html