P1101-1
Dedicated After-Sales Service Department
12 Months
Self-Starting Diesel Generator
Fixed
Four Stroke
Water Cooling
AC Three Phase
HSS
Land Use
Common Units, Standby Unit, Emergency Crew
Low Noise Automation Type
AC Rotating Exciter
480/277V, 60 Hz
Dry: 7137 (15734) Kg / Wet: 7250 (15983) Kg
Perkins
Options Available
FG WILSON
Shipping Containers
L4788 (188.5)mm*W2046 (80.6)mm*H2419 (95.2)mm
China
Product Description
Company Profile
*: Heat radiated from engine and alternator
Designed to operate in ambient conditions up to 50°C (122°F).
Contact your local FG Wilson Dealer for power ratings at specific site conditions.
Reactances shown are applicable to prime ratings.
*Based on 30% voltage dip at 0.6 power factor.
** With optional independant excitation system (PMG / AUX winding)
Introduction to other series of Wilson products

Body details
Open unit series:
Anti-corrosion and pressure-resistant hoses and sealed joints, the entire machine is coated with anti-corrosion topcoat


Closed unit series:
Hinged door panels on both sides facilitate maintenance.Anti-corrosion galvanized cold rolled plate

Support customization according to needs

Control System
Putting You in Control
Whatever your power requirements, FG Wilson can provide a control system to suit your needs. Our generator set experts design and validate FG Wilson control systems to optimise your generator set performance and put you in control.
All FG Wilson control panels are compact, versatile and easy to use. Our comprehensive range includes key-start analogue control panels for straightforward functionality and reliability; digital control panels suitable for use in mains failure applications, providing advanced metering, protection and diagnostics; and the next generation of advanced synchronising panels with integrated load management capability, suitable for synchronising up to 32 generator sets.
Our range of load transfer panels are designed to enhance the operation of your standby generator set in conjunction with our electronic control panels, to provide automatic control of your standby generator set in the event of a power outage, 24 hours a day, 365 days a year.
For more challenging power requirements, our Power Solutions Team is dedicated to the design and production of bespoke control systems to meet your individual needs, regardless of complexity.

Switch screen


Equipment production line

Applications
General list of Wilson open frame models
cument
Beijing Xinda Gongchuang Machinery Equipment Co., Ltd. mainly supplies diesel generator sets and gas generator sets and spare parts for the units, including well-known international and domestic brands, including British Wilson, American Carter, Weichai, Yuchai, etc., with output power ranging from 7KW -2500KW.Choose from open, silent, containerized and trailer-mounted generator sets.


Wilson product introduction
FG Wilson is one of the world's largest suppliers of diesel and natural gas generator sets and is well-known in the industry. Wilson adopts global unified standards to ensure that each generator set is designed and manufactured in accordance with the highest British standards. .All factories implement world-class manufacturing processes.Each factory is ISO 9001 and ISO 14001 certified to ensure delivery quality.
Wilson has a global logistics chain and a network of 370 dealers. Wilson can provide reliable product and service support no matter when and where users are.

Product advantages and details
Wilson Advantage:
1.Product advantages
*Startup performance:It takes 5 seconds to start cranking to reach a stable state, and it takes about 15 seconds to reach full load.
*Loading capacity:One-step loading capacity exceeds 50%
*Power density:High power density, small unit size
*Maintenance of the economy:Some parts of the 720-2000kw unit are interchangeable to reduce costs - the advantage of the high power section
*Extended warranty service---60-month extended warranty service
2.service advantage
*Customized services Wilson has a solution team of more than 200 people to design and produce customized products according to customers' special needs.
*,Advanced control and parallel system
*Remote cooling device
*Emission silencer system
*Rainproof and anti-speaker box
*High insulation level
*Customized testing
3.Complete solution-pre-sales support
*Equipment load calculation and generator set selection: According to the project equipment load requirements, calculate the actual power supply demand, taking into account reliability and economy

*Deepening of the engine room design: Based on project requirements and actual site conditions, deepen the diesel engine room design plan and provide professional suggestions; including diesel engine load-bearing foundation, engine room ventilation system, oil system, cable bridge, distribution cabinet layout, diesel engine room Hoisting etc.
4. Complete solution-after-sales support
Product certification information



P1101-1 model product specific information


Wilson product introduction
FG Wilson is one of the world's largest suppliers of diesel and natural gas generator sets and is well-known in the industry. Wilson adopts global unified standards to ensure that each generator set is designed and manufactured in accordance with the highest British standards. .All factories implement world-class manufacturing processes.Each factory is ISO 9001 and ISO 14001 certified to ensure delivery quality.
Wilson has a global logistics chain and a network of 370 dealers. Wilson can provide reliable product and service support no matter when and where users are.

Product advantages and details
Wilson Advantage:
1.Product advantages
*Startup performance:It takes 5 seconds to start cranking to reach a stable state, and it takes about 15 seconds to reach full load.
*Loading capacity:One-step loading capacity exceeds 50%
*Power density:High power density, small unit size
*Maintenance of the economy:Some parts of the 720-2000kw unit are interchangeable to reduce costs - the advantage of the high power section
*Extended warranty service---60-month extended warranty service
2.service advantage
*Customized services Wilson has a solution team of more than 200 people to design and produce customized products according to customers' special needs.
*,Advanced control and parallel system
*Remote cooling device
*Emission silencer system
*Rainproof and anti-speaker box
*High insulation level
*Customized testing
3.Complete solution-pre-sales support
*Equipment load calculation and generator set selection: According to the project equipment load requirements, calculate the actual power supply demand, taking into account reliability and economy

*Deepening of the engine room design: Based on project requirements and actual site conditions, deepen the diesel engine room design plan and provide professional suggestions; including diesel engine load-bearing foundation, engine room ventilation system, oil system, cable bridge, distribution cabinet layout, diesel engine room Hoisting etc.
4. Complete solution-after-sales support
*Provide professional product training
*FG Wilson Original Parts Consulting Help
*Ensure timely supply and delivery of parts
*Complete warranty, extended warranty and customer service agreements
*FG Wilson Original Parts Consulting Help
*Ensure timely supply and delivery of parts
*Complete warranty, extended warranty and customer service agreements

Product certification information



P1101-1 model product specific information

Engine Make | Perkins | ||
Engine Model: | 4008TAG2 | ||
Alternator Make | Leroy Somer | ||
Alternator Model: | LL7224P | ||
Control Panel: | DSE7410 | ||
Base Frame: | Heavy Duty Fabricated Steel | ||
Circuit Breaker Type: | Options Available | ||
Frequency: | 50 HZ | 60 HZ | |
Engine Speed: RPM | rpm | 1800 | |
Fuel Tank Capacity: | litres (USgal) | N/A (N/A) | |
Fuel Consumption Prime | litres (USgal)/hr | 221.2 (58.4) | |
Fuel Consumption Standby | litres (USgal)/hr | 244.4 (64.6) |
Engine Technical Data | ||
No. of Cylinders Alignment Cycle Bore Stroke Induction Cooling Method Governing Type Governing Class Compression Ratio Displacement Moment of Inertia: Voltage Ground Battery Charger Amps Engine Weight Dry Engine Weight Wet | mm (in) mm (in) L (cu. in) kg m² (lb/in²) kg (lb) kg (lb) | 8 IN LINE 4 STROKE 160 (6.3) 190 (7.5) TURBOCHARGED WATER ELECTRONIC ISO 8528 13.6:1 30.6 (1864.9) 15.62 (53376) 24 Negative 40 3250 (7165) 3428 (7557) |
Engine Performance Data | 50 Hz | 60 Hz | |
Engine Speed | rpm | 1800 | |
Gross Engine Power Prime Gross Engine Power Standby BMEP Prime | kW (hp) kW (hp) kPa (psi) | 898 (1204) 1004 (1346) 1959 (284.1) | |
BMEP Standby | kPa (psi) | 2190 (317.7) |
Fuel Filter Type: | Replaceable Element | ||||
Recommended Fuel: | Class A2 Diesel | ||||
Fuel Consumption at | 110 % Load | 100 % Load | 75 % Load | 50 % Load | |
50 Hz Prime: | l/hr (USgal/hr) | ||||
50 Hz Standby | l/hr (USgal/hr) | - | |||
60 Hz Prime | l/hr (USgal/hr) | 244.4 (64.6) | 221.2 (58.4) | 165.8 (43.8) | 114.1 (30.1) |
60 Hz Standby | l/hr (USgal/hr) | - | 244.4 (64.6) | 182 (48.1) | 124.2 (32.8) |
Air System | 50 Hz | 60 Hz | |
Air Filter Type: | Replaceable Element | ||
Combustion Air Flow Prime Combustion Air Flow Standby Max. Combustion Air Intake Restriction | m³/min (cfm) m³/min (cfm) kPa | 72 (2543) 77 (2719) 3.7 (14.9) |
Cooling System | 50 Hz | 60 Hz | ||
Cooling System Capacity | l (USgal) | 153 (40.4) | ||
Water Pump Type: Heat Rejected to Water & Lube Oil: Prime Heat Rejected to Water & Lube Oil: Standby Heat Radiation to Room*: Prime Heat Radiation to Room*: Standby Radiator Fan Load: Radiator Cooling Airflow: | kW (Btu/min) kW (Btu/min) kW (Btu/min) kW (Btu/min) kW (hp) m³/min (cfm) | Centrifugal | ||
337 (19165) 375 (21326) 126 (7165) 154 (6300) 56 (75.1) 1461 (51595) | ||||
External Restriction to Cooling Airflow: | Pa (in H2O) | 196 (0.8) |
Designed to operate in ambient conditions up to 50°C (122°F).
Contact your local FG Wilson Dealer for power ratings at specific site conditions.
Lubrication System | ||
Oil Filter Type: | Spin-On, Full Flow | |
Total Oil Capacity: Oil Pan Capacity: Oil Type: | l (USgal) l (USgal) | 166 (43.9) 153 (40.4) API CG4 15W-40 |
Oil Cooling Method: | WATER |
Exhaust System | 50 Hz | 60 Hz | |
Maximum Allowable Back Pressure: | kPa (inHg) | 6.7 (2) | |
Exhaust Gas Flow: Prime Exhaust Gas Flow: Standby Exhaust Gas Temperature: Prime | m³/min (cfm) m³/min (cfm) °C (°F) | 207 (7310) 207 (7310) 490 (914) | |
Exhaust Gas Temperature: Standby | °C (°F) | 520 (968) |
Alternator Physical Data | ||
No. of Bearings: | 1 | |
Insulation Class: Winding Pitch: Winding Code Wires: Ingress Protection Rating: Excitation System: AVR Model: | H 2/3 6S 6 IP23 AREP R450M | |
* dependant on voltage code selected | ||
Alternator Operating Data | ||
Overspeed: rpm | 2250 | |
Voltage Regulation: (Steady state) Wave Form NEMA = TIF: Wave Form IEC = THF: Total Harmonic content LL/LN: Radio Interference: Radiant Heat: 50 Hz Radiant Heat: 60 Hz | % % % kW (Btu/min) kW (Btu/min) | +/- 0.5 50 2 4 EN61000-6 44 (2502) |
Alternator Performance Data 50 Hz: | |||||
Voltage Code | |||||
Motor Starting Capability* Short Circuit Capacity** Reactances | kVA % Xd X'd X"d | 300 | 300 | 300 | 300 |
Voltage Code | 480/277 V | 380/220 V | 440/254 V | |||
Motor Starting Capability* Short Circuit Capacity** Reactances | kVA % Xd X'd X"d | 3121 300 2.839 0.135 0.108 | 2017 300 4.519 0.215 0.172 | 300 | 300 | 2657 300 3.379 0.16 0.128 |
*Based on 30% voltage dip at 0.6 power factor.
** With optional independant excitation system (PMG / AUX winding)
Output Ratings 50 Hz | |||
Voltage Code 415/240V 400/230V 380/220V 230/115V 220/127V 220/110V 200/115V | Prime kVA | Standby kW kVA | kW |
240V 230V 220V |
Output Ratings 60 Hz | ||||
Prime | Standby | |||
Voltage Code | kVA | kW | kVA | kW |
480/277V | 1000 | 800 | 1100 | 880 |
440/254V 416/240V 400/230V | 1000 | 800 | 1100 | 880 |
380/220V | 997.4 | 797.9 | 1100 | 880 |
240/139V 240/120V 230/115V 220/127V 220/110V 208/120V | ||||
240/120 | ||||
220/110 |
Introduction to other series of Wilson products


Open unit series:
Anti-corrosion and pressure-resistant hoses and sealed joints, the entire machine is coated with anti-corrosion topcoat

500 Series Perkins engines provide the right reliability for a variety of applications and markets

The components are easy to operate, allowing service and maintenance to be performed quickly and efficiently.Lubricants and cooling

To facilitate installation work, cables can be laid directly under the control panel, while the control panel tower
Closed unit series:
Hinged door panels on both sides facilitate maintenance.Anti-corrosion galvanized cold rolled plate

Support customization according to needs


Control System
Putting You in Control
Whatever your power requirements, FG Wilson can provide a control system to suit your needs. Our generator set experts design and validate FG Wilson control systems to optimise your generator set performance and put you in control.
All FG Wilson control panels are compact, versatile and easy to use. Our comprehensive range includes key-start analogue control panels for straightforward functionality and reliability; digital control panels suitable for use in mains failure applications, providing advanced metering, protection and diagnostics; and the next generation of advanced synchronising panels with integrated load management capability, suitable for synchronising up to 32 generator sets.
Our range of load transfer panels are designed to enhance the operation of your standby generator set in conjunction with our electronic control panels, to provide automatic control of your standby generator set in the event of a power outage, 24 hours a day, 365 days a year.
For more challenging power requirements, our Power Solutions Team is dedicated to the design and production of bespoke control systems to meet your individual needs, regardless of complexity.

Switch screen


Equipment production line

Applications

model number | Voltage, Frequency | Prime Power | Standby Power | Engine Make | Engine model | Alternator Make | Alternator model | Fuel consumption (L/h) | Dimensions (mm) | Weight | ||||
KVA | KW | KVA | KW | Prime | Standby | Dry(kg) | Wet(kg) | |||||||
P7.5-1S | 230 V, 50 Hz | 6.8 | 6.8 | 7.5 | 7.5 | Perkins | 403A-11G1 | FG Wilson | FGL10030 | 2.5 (0.7) | 2.8 (0.7) | 1550×620×1020 | 233 | 238 |
P7.5-4S | 230 V, 50 Hz | 6.8 | 6.8 | 7.5 | 7.5 | Perkins | 403D-11G | FG Wilson | FGL10030 | 2.5 (0.7) | 2.8 (0.7) | 1550×620×1020 | 233 | 238 |
240/120 V, 60 Hz | 8 | 8 | 8.8 | 8.8 | Perkins | 403D-11G | FG Wilson | FGL10030 | 2.9 (0.8) | 3.3 (0.9) | 1550×620×1020 | 233 | 238 | |
P9.5-1 | 400/230 V, 50 Hz | 8.5 | 6.8 | 9.5 | 7.6 | Perkins | 403A-11G1 | FG Wilson | FGL10020 | 2.5 (0.7) | 2.8 (0.7) | 1550×620×1020 | 226 | 231 |
P9.5-4 | 400/230 V, 50 Hz | 8.5 | 6.8 | 9.5 | 7.6 | Perkins | 403D-11G | FG Wilson | FGL10020 | 2.7 (0.7) | 3 (0.8) | 1550×620×1020 | 226 | 231 |
220/127 V, 60 Hz | 10 | 8 | 11 | 8.8 | Perkins | 403D-11G | FG Wilson | FGL10020 | 2.9 (0.8) | 2.9 (0.8) | 1550×620×1020 | 226 | 231 | |
P11-6S | 230 V, 50 Hz | 9.9 | 9.9 | 10.9 | 10.9 | Perkins | 403D-15G | FG Wilson | FGL10030 | 3.6 (1) | 4 (1.1) | 1550×620×1020 | 309 | 315 |
240/120 V, 60 Hz | 11.8 | 11.8 | 12.9 | 12.9 | Perkins | 403D-15G | FG Wilson | FGL10030 | 4.3 (1.1) | 4.8 (1.3) | 1550×620×1020 | 309 | 315 | |
P13.5-6 | 400/230 V, 50 Hz | 12.4 | 9.92 | 13.5 | 10.8 | Perkins | 403D-15G | FG Wilson | FGL10020 | 3.6 (1) | 4 (1.1) | 1550×620×1020 | 302 | 308 |
220/127 V, 60 Hz | 15 | 12 | 16.4 | 13.12 | Perkins | 403D-15G | FG Wilson | FGL10020 | 4.3 (1.1) | 4.8 (1.3) | 1550×620×1020 | 302 | 308 | |
P14-6S | 230 V, 50 Hz | 13 | 13 | 14 | 14 | Perkins | 404D-22G1 | FG Wilson | FGL10040 | 4.3 (1.1) | 4.6 (1.2) | 1550×620×1020 | 370 | 377 |
240/120 V, 60 Hz | 14.5 | 14.5 | 16 | 16 | Perkins | 404D-22G1 | FG Wilson | FGL10040 | 4.8 (1.3) | 5.3 (1.4) | 1550×620×1020 | 370 | 377 | |
P16.5-1S | 230 V, 50 Hz | 15 | 15 | 16.5 | 16.5 | Perkins | 404A-22G1 | FG Wilson | FGL10060 | 5 (1.3) | 5.6 (1.5) | 1550×620×1020 | 378 | 385 |
P16.5-6S | 230 V, 50 Hz | 15 | 15 | 16.5 | 16.5 | Perkins | 404D-22G | Leroy Somer | LLB1114M | 4.9 (1.3) | 5.5 (1.5) | 1500×620×1115 | 447 | 454 |
240/120 V, 60 Hz | 17.6 | 17.6 | 19.4 | 19.4 | Perkins | 404D-22G | Leroy Somer | LLB1114M | 5.7 (1.5) | 6.3 (1.7) | 1500×620×1115 | 447 | 454 | |
P16-1 (skid) | 400/230V, 50 Hz | 14.5 | 11.6 | 16 | 12.8 | Perkins | 403A-15G2 | Leroy Somer | LL1114M | 4.1 (1.1) | 4.7 (1.2) | 1500×860×895 | 333 | 339 |
P18-6 | 400/230 V, 50 Hz | 16.5 | 13.2 | 18 | 14.4 | Perkins | 404D-22G1 | FG Wilson | FGL10040 | 4.4 (1.2) | 4.8 (1.3) | 1550×620×1020 | 365 | 372 |
220/127 V, 60 Hz | 20 | 16 | 22 | 17.6 | Perkins | 404D-22G1 | FG Wilson | FGL10040 | 5.3 (1.4) | 5.8 (1.5) | 1550×620×1020 | 365 | 372 | |
P22-1 | 400/230 V, 50 Hz | 20 | 16 | 22 | 17.6 | Perkins | 404A-22G1 | FG Wilson | FGL10060 | 5.4 (1.4) | 6.1 (1.6) | 1550×620×1020 | 378 | 385 |
P22-6 (skid) | 400/230V, 50 Hz | 20 | 16 | 22 | 17.6 | Perkins | 404D-22G | Leroy Somer | LL1114M | 5.3 (1.4) | 5.9 (1.6) | 1500×860×895 | 383 | 389 |
220/127V, 60 Hz | 22.5 | 18 | 25 | 20 | Perkins | 404D-22G | Leroy Somer | LL1114M | 5.8 (1.5) | 6.5 (1.7) | 1500×860×895 | 383 | 389 | |
P26-3S | 230 V, 50 Hz | 24 | 24 | 26 | 26 | Perkins | 1103A-33G1 | FG Wilson | FGL20050-M | 6.8 (1.8) | 7.4 (2) | 1570×760×1231 | 695 | 708 |
P26-6S | 230 V, 50 Hz | 24 | 24 | 26 | 26 | Perkins | 1103D-33G3 | FG Wilson | FGL20050-M | 7.3 (1.9) | 7.8 (2.1) | 1570×760×1231 | 695 | 708 |
P33-3 | 400/230 V, 50 Hz | 30 | 24 | 33 | 26.4 | Perkins | 1103A-33G1 | FG Wilson | FGL20030 | 6.9 (1.8) | 7.7 (2) | 1570×760×1231 | 660 | 673 |
P33-6 | 400/230 V, 50 Hz | 30 | 24 | 33 | 26.4 | Perkins | 1103D-33G3 | FG Wilson | FGL20030 | 7.4 (2) | 8.2 (2.2) | 1570×760×1231 | 660 | 673 |
P50-3 | 400/230 V, 50 Hz | 45 | 36 | 50 | 40 | Perkins | 1103A-33TG1 | FG Wilson | FGL20060 | 10.5 (2.8) | 11.7 (3.1) | 1680×760×1330 | 751 | 764 |
P50-5S | 230 V, 50 Hz | 45 | 45 | 50 | 50 | Perkins | 1103A-33TG2 | FG Wilson | FGL30030-M | 12.6 (3.3) | 14.1 (3.7) | 1680×760×1330 | 864 | 887 |
P55-3 | 400/230 V, 50 Hz | 50 | 40 | 55 | 44 | Perkins | 1103A-33TG2 | FG Wilson | FGL20070 | 11.6 (3.1) | 12.8 (3.4) | 1680×760×1330 | 756 | 769 |
P55-4 | 400/230 V, 50 Hz | 50 | 40 | 55 | 44 | Perkins | 1104C-44TG2/3 | FG Wilson | FGL20070 | 15.9 (4.2) | 17.4 (4.6) | 1870×840×1333 | 818 | 831 |
P55-6S | 230 V, 50 Hz | 50 | 50 | 55 | 55 | Perkins | 1104D-44TG2/3 | FG Wilson | FGL30030-M | 17.1 (4.5) | 19.1 (5) | 1870×840×1333 | 936 | 949 |
P65-5 | 400/230 V, 50 Hz | 60 | 48 | 65 | 52 | Perkins | 1103A-33TG2 | FG Wilson | FGL20080 | 13.7 (3.6) | 15 (4) | 1680×760×1330 | 765 | 778 |
P65-6 | 400/230 V, 50 Hz | 60 | 48 | 65 | 52 | Perkins | 1104D-44TG2/3 | FG Wilson | FGL20080 | 16.6 (4.4) | 18.3 (4.8) | 1870×840×1333 | 827 | 840 |
P88-3 | 400/230 V, 50 Hz | 80 | 64 | 88 | 70.4 | Perkins | 1104A-44TG2 | FG Wilson | FGL30020 | 18.2 (4.8) | 20.1 (5.3) | 1870×840×1333 | 939 | 952 |
P88-6 | 400/230 V, 50 Hz | 80 | 64 | 88 | 70.4 | Perkins | 1104D-E44TAG1 | FG Wilson | FGL30020 | 19.4 (5.1) | 21 (5.5) | 1980×890×1398 | 1068 | 1085 |
P90-3S | 230 V, 50 Hz | 82 | 82 | 90 | 90 | Perkins | 1104C-44TAG2 | FG Wilson | FGL30100-M | 22.1 (5.8) | 24.3 (6.4) | 1980×890×1374 | 1151 | 1169 |
P90-6S | 230 V, 50 Hz | 81.7 | 81.7 | 89.8 | 89.8 | Perkins | 1104D-E44TAG2 | FG Wilson | FGL30100-M | 23.6 (6.2) | 24.9 (6.6) | 1980×890×1374 | 1229 | 1246 |
P110-3 | 400/230 V, 50 Hz | 100 | 80 | 110 | 88 | Perkins | 1104C-44TAG2 | FG Wilson | FGL30040 | 21.7 (5.7) | 23.9 (6.3) | 1980×890×1374 | 1019 | 1036 |
P110-6 | 400/230 V, 50 Hz | 100 | 80 | 110 | 88 | Perkins | 1104D-E44TAG2 | FG Wilson | FGL30040 | 23.8 (6.3) | 25.5 (6.7) | 1980×890×1374 | 1136 | 1156 |
P150-5 | 400V, 50 Hz | 135 | 108 | 150 | 120 | Perkins | 1106A-70TG1 | Marelli | MJB225LA4 | 29.9 (7.9) | 33.4 (8.8) | 2450×1010×1544 | 1407 | 1428 |
480V, 60 Hz | 150 | 120 | 165 | 132 | Perkins | 1106A-70TG1 | Marelli | MJB225LA4 | 33.1 (8.7) | 36.7 (9.7) | 2450×1010×1544 | 1407 | 1428 | |
P165-5 | 400V, 50 Hz | 150 | 120 | 165 | 132 | Perkins | 1106A-70TAG2 | Marelli | MJB 250 MA4 | 32.4 (8.6) | 35.1 (9.3) | 2450×1010×1544 | 1545 | 1566 |
480V, 60 Hz | 168.8 | 132 | 187.5 | 150 | Perkins | 1106A-70TAG2 | Marelli | MJB 250 MA4 | 37.9 (10.0) | 41.6 (11.0) | 2450×1010×1544 | 1545 | 1566 | |
P200-3 | 400V, 50 Hz | 180 | 144 | 200 | 160 | Perkins | 1106A-70TAG3 | Marelli | MJB 250 MB4 | 39.8 (10.5) | 43.2 (11.4) | 2510×1010×1640 | 1552 | 1579 |
480V, 60 Hz | 200 | 160 | 218.8 | 175 | Perkins | 1106A-70TAG3 | Marelli | MJB 250 MB4 | 46.5 (12.3) | 50.6 (13.4) | 2510×1010×1640 | 1552 | 1579 | |
P220-3 | 400/230 V, 50 Hz | 200 | 160 | 220 | 176 | Perkins | 1106A-70TAG4 | FG Wilson | FGL30120 | 45.1 (11.9) | 49 (12.9) | 2510×1010×1640 | 1506 | 1522 |
P249-5-60Hz | 480/277V, 60 Hz | 225 | 180 | 250 | 200 | Perkins | 1506A-E88TAG2 | Leroy Somer | LL5114F | 49.7 (13.1) | 54.6 (14.4) | 2662×1071×1818 | 1952 | 1985 |
P250-5 | 400/230 V, 50 Hz | 230 | 184 | 250 | 200 | Perkins | 1506A-E88TAG2 | Leroy Somer | LL5114H | 47.2 (12.5) | 50.7 (13.4) | 2662×1071×1818 | 2035 | 2068 |
P275-2 | 400/230 V, 50 Hz | 250 | 200 | 275 | 220 | Perkins | 1506D-E88TAG4 | Leroy Somer | LL5114H | 56.6 (15) | 60.6 (16) | 2662×1071×1818 | 2035 | 2068 |
P275-5 | 400/230 V, 50 Hz | 250 | 200 | 275 | 220 | Perkins | 1506A-E88TAG3 | Leroy Somer | LL5114H | 53.8 (14.2) | 59.2 (15.6) | 2662×1071×1818 | 2035 | 2068 |
P300-4 | 400/230 V, 50 Hz | 275 | 220 | 300 | 240 | Perkins | 1506D-E88TAG4 | FG Wilson | FG26A230 | 60.2 (15.9) | 64.3 (17) | 2675×1071×1818 | 2077 | 2100 |
P300-5 | 400/230 V, 50 Hz | 275 | 220 | 300 | 240 | Perkins | 1506A-E88TAG4 | FG Wilson | FG26A230 | 59 (15.6) | 64.5 (17) | 2675×1071×1818 | 2077 | 2100 |
P313-5-60Hz | 480/277V, 60 Hz | 281.3 | 225.04 | 312.5 | 250 | Perkins | 1506A-E88TAG3 | Leroy Somer | LL5114H | 60.8 (16.1) | 67.6 (17.9) | 2662×1071×1818 | 2035 | 2068 |
P330-5 | 400/230 V, 50 Hz | 300 | 240 | 330 | 264 | Perkins | 1506A-E88TAG5 | FG Wilson | FG26A250 | 62.8 (16.6) | 70.1 (18.5) | 2785×1071×1818 | 2228 | 2261 |
P344-5-60Hz | 480/277V, 60 Hz | 312.5 | 250 | 343.8 | 275.04 | Perkins | 1506A-E88TAG4 | FG Wilson | FG26A250 | 66.7 (17.6) | 73.7 (19.5) | 2785×1071×1818 | 2228 | 2261 |
P375-4-60Hz | 480/277V, 60 Hz | 343.8 | 275.04 | 375 | 300 | Perkins | 1506D-E88TAG4 | FG Wilson | FG26A250 | 73.3 (19.4) | 80.5 (21.3) | 2785×1071×1818 | 2228 | 2261 |
P375-5-60Hz | 480/277V, 60 Hz | 337.5 | 270 | 375 | 300 | Perkins | 1506A-E88TAG5 | FG Wilson | FG26A250 | 71.9 (19) | 80.5 (21.3) | 2785×1071×1818 | 2228 | 2261 |
P400-3-SA | 400/230 V, 50 Hz | 350 | 280 | 400 | 320 | Perkins | 2206A-E13TAG2 | FG Wilson | FG29A280 | 68.6 (18.1) | 77.8 (20.6) | 3800×1131×2156 | 3103 | 3161 |
P438-3-SA-60Hz | 480/277V, 60 Hz | 400 | 320 | 437.5 | 350 | Perkins | 2206A-E13TAG5 | FG Wilson | FG29A280 | 80.4 (21.2) | 88.1 (23.3) | 3800×1131×2156 | 3103 | 3161 |
P450-2-SA | 400/230 V, 50 Hz | 400 | 320 | 450 | 360 | Perkins | 2206D-E13TAG3A | FG Wilson | FG29A320 | 88.5 (23.4) | 97.8 (25.8) | 3800×1131×2156 | 3175 | 3233 |
P450-3-SA | 400/230 V, 50 Hz | 400 | 320 | 450 | 360 | Perkins | 2206A-E13TAG3 | FG Wilson | FG29A320 | 78.2 (20.7) | 87.2 (23) | 3800×1131×2156 | 3195 | 3253 |
P500-3-SA | 400/230 V, 50 Hz | 450 | 360 | 500 | 400 | Perkins | 2506A-E15TAG1 | FG Wilson | FG29A360 | 91.3 (24.1) | 101.5 (26.8) | 3800×1131×2215 | 3603 | 3661 |
P501-3-SA-60Hz | 480/277V, 60 Hz | 437.5 | 350 | 500 | 400 | Perkins | 2206A-E13TAG6 | FG Wilson | FG29A320 | 87.8 (23.2) | 99.4 (26.3) | 3800×1131×2156 | 3195 | 3253 |
P550-2-SA | 400/230 V, 50 Hz | 500 | 400 | 550 | 540 | Perkins | 2506D-E15TAG2 | FG Wilson | FG29A400 | 104 (27.5) | 113.9 (30.1) | 3787×1481×2193.4 | 3784 | 3832 |
P550-3-SA | 400/230 V, 50 Hz | 500 | 400 | 550 | 540 | Perkins | 2506A-E15TAG2 | FG Wilson | FG29A400 | 97.2 (25.7) | 107.4 (28.4) | 3800×1131×2215 | 3641 | 3699 |
P563-3-SA-60Hz | 480/277V, 60 Hz | 512.5 | 410 | 562.5 | 450 | Perkins | 2506A-E15TAG3 | FG Wilson | FG29A360 | 101.6 (26.8) | 111.3 (29.4) | 3800×1131×2215 | 3603 | 3661 |
P605-3 | 400/230 V, 50 Hz | 550 | 440 | 605 | 484 | Perkins | 2806A-E18TAG1 | FG Wilson | FG33A450 | 107.4 (28.4) | 119 (31.4) | 3900×1461×2156 | 4134 | 4202 |
P625-3-SA-60Hz | 480/277V, 60 Hz | 568.8 | 455.04 | 625 | 500 | Perkins | 2506A-E15TAG4 | FG Wilson | FG29A400 | 112.8 (29.8) | 123.2 (32.5) | 3800×1131×2215 | 3641 | 3699 |
P660-3 | 400/230 V, 50 Hz | 600 | 480 | 660 | 528 | Perkins | 2806A-E18TAG1A | FG Wilson | FG33A500 | 118.5 (31.3) | 131.1 (34.6) | 3900×1461×2156 | 4274 | 4342 |
P688-3-60Hz | 480/277V, 60 Hz | 625 | 500 | 687.5 | 550 | Perkins | 2806A-E18TAG1A | FG Wilson | FG33A500 | 124.6 (32.9) | 138.2 (36.5) | 3900×1461×2156 | 4274 | 4342 |
P715-3 | 400/230 V, 50 Hz | 650 | 520 | 715 | 572 | Perkins | 2806A-E18TAG2 | FG Wilson | FG33A560 | 127.6 (33.7) | 142 (37.5) | 3900×1461×2156 | 4454 | 4522 |
P750-3-60Hz | 480/277V, 60 Hz | 681.3 | 545.04 | 750 | 600 | Perkins | 2806A-E18TAG3 | FG Wilson | FG33A500 | 138.9 (36.7) | 155 (40.9) | 3900×1461×2156 | 4274 | 4342 |
P780-1-SA | 400/230 V, 50 Hz | 706 | 564.8 | 780 | 624 | Perkins | 2806A-E18TTAG4 | Leroy Somer | LL7224J | 144.2 (38.1) | 160.6 (42.4) | 4130×1690×2570 | 4869 | 4979 |
P813-1-SA-60Hz | 480/277V, 60 Hz | 750 | 600 | 812.5 | 650 | Perkins | 2806A-E18TTAG6A | Leroy Somer | LL7224H | 160.7 (42.5) | 176 (46.5) | 4130×1690×2570 | 4724 | 4834 |
P850-1-SA | 400/230 V, 50 Hz | 770 | 616 | 850 | 680 | Perkins | 2806A-E18TTAG5 | Leroy Somer | LL7224L | 160.3 (42.3) | 179.9 (47.5) | 4130×1690×2570 | 4930 | 5040 |
P895-1-SA-60Hz | 480/277V, 60 Hz | 812.5 | 650 | 895 | 710 | Perkins | 2806A-E18TTAG6A | Leroy Somer | LL7224J | 172.8 (45.6) | 192 (50.7) | 4130×1690×2570 | 4869 | 4979 |
P938-1-60Hz | 480/277V, 60 Hz | 850 | 680 | 937.5 | 750 | Perkins | 2806A-E18TTAG7 | Leroy Somer | LL7224L | 183.3 (48.4) | 204.7 (54.1) | 4130×1690×2570 | 4930 | 5040 |
P900-1 | 400/230 V, 50 Hz | 800 | 640 | 892 | 713.6 | Perkins | 4006-23TAG3A | FG Wilson | FGL70030 | 172.9 (45.7) | 195.5 (51.6) | 4280×1731×2379 | 5818 | 5938 |
P1000-1 | 400/230 V, 50 Hz | 910 | 728 | 1000 | 800 | Perkins | 4008TAG1A | FG Wilson | FGL70040 | 191.8 (50.7) | 213.9 (56.5) | 4788×2046×2419 | 7032 | 7145 |
P1001-1-60Hz | 480/277V, 60 Hz | 900 | 720 | 1000 | 800 | Perkins | 4008TAG1A | Leroy Somer | LL7224N | 198.3 (52.4) | 223.2 (59) | 4788×2046×2419 | 7088 | 7201 |
P1100-1 | 400/230 V, 50 Hz | 1000 | 800 | 1100 | 880 | Perkins | 4008TAG2A | FG Wilson | FGL70050 | 214 (56.5) | 240 (63.4) | 4788×2046×2419 | 7111 | 7224 |
P1101-1-60Hz | 480/277V, 60 Hz | 1000 | 800 | 1100 | 880 | Perkins | 4008TAG2A | Leroy Somer | LL7224P | 221.2 (58.4) | 244.4 (64.6) | 4788×2046×2419 | 7137 | 7250 |
P1250-1 | 400/230 V, 50 Hz | 1125 | 900 | 1250 | 1000 | Perkins | 4008-30TAG3 | Leroy Somer | LL8224H | 240.1 (63.4) | 266.3 (70.3) | 4789×2197×2069 | 7613 | 7753 |
P1375-1 | 400/230 V, 50 Hz | 1250 | 1000 | 1375 | 1100 | Perkins | 4012-46TWG2A | Leroy Somer | LL8224H | 258 (68.2) | 284.9 (75.3) | 4788×1895×2440 | 8884 | 9080 |
480/277V, 60 Hz | 1250 | 1000 | 1375 | 1100 | Perkins | 4012-46TWG2A | Leroy Somer | LL8224H | 266 (70.3) | 298 (78.7) | 4788×1895×2440 | 8884 | 9080 | |
P1500-1 | 400/230 V, 50 Hz | 1350 | 1080 | 1500 | 1200 | Perkins | 4012-46TWG3A | Leroy Somer | LL8224L | 279.2 (73.8) | 313.4 (82.8) | 4888×1895×2455 | 9247 | 9448 |
480/277V, 60 Hz | 1350 | 1080 | 1500 | 1200 | Perkins | 4012-46TWG3A | Leroy Somer | LL8224L | 289 (76.3) | 324 (85.6) | 4888×1895×2455 | 9247 | 9448 | |
P1650-1 | 400/230 V, 50 Hz | 1500 | 1200 | 1650 | 1320 | Perkins | 4012-46TAG2A | Leroy Somer | LL8224N | 296.6 (78.4) | 326.3 (86.2) | 5044×2200×2461 | 10181 | 10388 |
P1875-1 | 400/230 V, 50 Hz | 1700 | 1360 | 1875 | 1500 | Perkins | 4012-46TAG3A | Leroy Somer | LL9324F | 349.7 (92.4) | 390.2 (103.1) | 5259×2192×2453 | 10997 | 11207 |
P2000-3 | 400/230 V, 50 Hz | 1850 | 1480 | 2000 | 1600 | Perkins | 4016-61TRG1 | Leroy Somer | LL9324F | 383.8 (101.4) | 409.1 (108.1) | 5839×2196×2605 | 12215 | 12528 |
P2250-3 | 400/230 V, 50 Hz | 2000 | 1600 | 2250 | 1800 | Perkins | 4016-61TRG2 | Leroy Somer | LL9324H | 418.1 (110.5) | 470.8 (124.4) | 5839×2196×2605 | 12215 | 12528 |
P2500-3 | 400/230 V, 50 Hz | 2250 | 1800 | 2500 | 2000 | Perkins | 4016-61TRG3 | Leroy Somer | LL9324P | 470.6 (124.3) | 528.4 (139.6) | 6038×2184×2900 | 12980 | 13380 |
cument
ation
Operation and maintenance manual including circuit wiring diagrams.
Generator Set Standards
The equipment meets the following standards: BS5000, ISO 8528, ISO 3046, IEC 60034, NEMA MG-1.22.
Warranty
6.8 - 750 kVA electric power generation products in prime applications the warranty period is 12 months from date of start-up, unlimited hours (8760). For standby
applications the warranty period is 24 months from date of start-up, limited to 500 hours per year.
730 - 2500 kVA electric power generation products in prime applications the warranty period is 12 months from date of start-up, unlimited hours (8760 hours) or 24
months from date of start-up, limited to 6000 hours. For standby applications the warranty period is 36 months from date of start-up, limited to 500 hours per year.
FG Wilson manufactures product in the following locations:
Northern Ireland • Brazil • China • India
With headquarters in Northern Ireland, FG Wilson operates through a Global Dealer Network.