Ascb1-63 Intelligent Circuit Breaker Remote Control for Low-Voltage Terminal Distribution Networks

Price $103.00 Compare
Min Order 1 Piece
Shipping From Jiangsu, China
Popularity 488 people viewed
Quantity
+-
 

Jiangsu Acrel Microgrid Institute Co., Ltd

VIP   Audited Supplier 4 years
Profile Certified by SGS/BV
ASCB1-63
230V (1p/2p), 400V (3p/4p)
16A, 32A, 63A
IP20
20000 Times
6000 Times
6000A
C/D
Acrel
Carton
China
Product Description
Product Description

ASCB1-63-C16-2P intelligent circuit breaker remote control is a brand new smart power product launched by Acrel. ASCB1 series product consists of an intelligent miniature circuit breaker and an intelligent gateway, which can be used for real-time monitoring of key electrical factors of power lines, such as voltage, current, power, temperature, leakage, energy consumption, etc. It has functions such as remote control, early warning protection, short-circuit protection, energy measurement statistics, fault location, etc., and is used in low-voltage terminal distribution networks in industrial, commercial, civil buildings and infrastructure in indoor buildings and similar places.

 Rated voltage: 230V (1P/2P), 400V (3P/4P)

 Rated current: 16A,32A,63A

 Rated short-circuit breaking capacity: 6000A

 Real-time monitoring of electric parameters such as voltage, current, power, electrical energy and temperature

Overvoltage, undervoltage, overload, short circuit, overcurrent and overtemperature protection

 With local manual push rod, local electric control, local lock, remote control, timing control and so on

RS485 (Modbus-RTU) standard, with Ethernet and 4G optional


Parameters
ModelASCB1-63ASCB1LE-63
Pole1P/2P/3P/4P2P/4P
Grade of Shell63A
Rated Voltage230V(1P/2P),400V(3P/4P)
Rated Current6A,10A,16A,20A,25A,32A,40A,50A,63A
Instantaneous Unbuckle TypeC/D
Rated Short-circuit Breaking Capacity6000A

 

Leakage self-InspectionNoManual button self-inspection
Mechanical Life20000 times
Electrical Life6000 times
Levels of ProtectionIP20
Connection Capacity1-35mm²
Elevation Requirements2000m
Ambient Temperature-10ºC~55ºC,the average temperature at 24h was no higher than 40ºC
Way to InstallationStandard 35mm guide rail installation
 
Function
ProtectOver-current ProtectionDefault 100% rated current alert,110% Rated current trip with adjustable threshold
Short-circuit Protection5-10 Rated current for 0.04 seconds for circuit break protection
Overload ProtectionDefault 100% rated power alert,110% Rated power trip with adjustable threshold
Over-voltage ProtectionDefault 110% rated voltage alert,120% rated voltage trip with adjustable threshold
Under-voltage ProtectionDefault 90% rated voltage alert,80% rated voltage trip with adjustable threshold
Over-temperature ProtectionDefault 80ºC alert,100ºC trip, the threshold is adjustable
Leakage ProtectionNoDefault 20mA alert, 30mA trip, the threshold is adjustable


Installation Method

Network

 
Wiring

Features

1. Monitor voltage, current, power, electric energy, temperature and other parameters in real time

2. With multiple protection functions such as over-voltage, under-voltage, overload, short circuit, over-current, over-temperature, etc.

3. With local handle on-off, local electric control, local locking, remote control, timing control and other control functions

4. Standard configuration RS-485 (MODBUS) communication, optional tripping curve type C/D

5. Guide rail installation, optional module 1P/2P/3P/4P

FAQ

Q: Can the circuit breaker data be collected through RS485 communication?

 

A: The circuit breaker has its own RS485 communication interface, and it does not need to be equipped with an ASCB1-M gateway to access the customer system, but the customer needs to provide the circuit breaker with DC12V 12A auxiliary power supply

 

 

Q: How many circuit breakers can a gateway carry?

 

A: 16PCS

 

Q: How Gateways and Circuit Breakers are Networked?

 

A: The gateway and the circuit breaker are connected by a 4pin cable, a set of DC12V auxiliary power supply, and a set of RS485 communication lines.
The connection between the circuit breaker and the circuit breaker is the same.
One-key addressing operation through the gateway

 

Q: Does the circuit breaker need to be equipped with additional accessories?

 

A: 1. Internally integrate various sensor modules, including: current sensor, leakage transformer, temperature sensor, etc.;
2. The circuit breaker integrates the release function, which can realize remote opening and closing operations;
3. Configure the circuit breaker network cable

Photos on Site